Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
High Voltage 9 Pin D-Type Cables - Connector to Unterminated
The connector to unterminated cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
DC Voltage Sensors
DC voltage sensors monitor input voltages ranging from 3 to 500 volts DC with a trip point accuracy of up to 1% in airborne, military and ground power applications. Using internal electronic circuits to detect, monitor and/or sense DC voltage, DARE DC voltage sensors, monitors, and voltage sensing relays can open or close a circuit when a certain pre-set over or under voltage condition exists or the DC voltage falls outside the specified voltage band window.
-
product
NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783311-01
±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.
-
product
C Series Strain/Bridge Input Module
The C Series Strain/Bridge Input Module works with higher-channel-count, dynamic strain measurement systems. Modules can acquire measurements from up to eight channels, with compatibility options for quarter-, half-, and full-bridge sensors. The C Series Strain/Bridge Input Module is ideal for application channels requiring measurements at particular times, such as impact tests. It includes built-in voltage excitation, as well as transient isolation for high-common-mode noise rejection and improved safety.The C Series Strain/Bridge Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
FD-11601, 8-Channel, ±10 V Powered-Sensor Voltage Input Device for FieldDAQ
786374-01
The FD-11601 measures up to eight channels with a voltage input range of ±10 V. Each input channel supports TEDS and provides 24 V DC to power external-powered sensors without additional power supplies. The FD-11601 features 24-bit resolution, simultaneous sample rates up to 100 kS/s/ch, and channel-to-channel isolation. It is IP65/IP67 rated to be dust-tight and water-submersible, operates in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11601 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11601 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11601 is ideal for test cell and outdoor environments.
-
product
PXI 10 Channel High Voltage Attenuator
41-660-001
The 41-660 and 41-661 are high voltage attenuators designed to reduce the high output voltages commonly generated by some types of sensors. This is in order to produce manageable signal levels that can be acquired by typical data acquisition devices in a PXI system.
-
product
Float Sensors
Omega's Float Operated Continuous Level Sensors have 316 SS wetted parts, come in ranges up to six feet, and are available with 4-20 mA, or Voltage outputs.
-
product
Digital Recorder
HiRES
HIGHVOLT Prüftechnik Dresden GmbH
The digital recorders HiRES are used to measure, store, and evaluate signals from up to 64 sources synchronously. Depending on the sensors used voltages, currents, temperatures, mechanical movements and various other signals can be measured. This measurement system features the ability to capture fast transient processes such as those occurring in impulse current tests on electrical devices or during switchgear testing. The system is also capable of measuring semistationary and periodic events such as DC voltage and AC voltage as well as superimposed semistationary, periodic and transient processes.
-
product
15-CH Isolated Digital Output Module
ND-6056
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
product
Process / Voltage / Current
Calibrator high precision process signals (150 ppm of reading) able to measure and generate current and voltage. Simple and robust, this tool has been designed to simplify maintenance and commissioning of sensors and transmitters using the process signals such as 4-20 mA or 0-10 V.
-
product
Digital Telemetry Solutions
For measurements on rotating components and moving machinery, imc offers modern telemetry systems for a wide variety of tasks: whether single-channel torque monitoring of a rotating shaft, multi-channel strain gauge and temperature measurements on a train wheel-set or non-contact power measurement on a vehicle drivetrain in harsh environments. There are transmission electronics available for a large variety of sensors, such as strain gauge (quarter-, half- and full-bridge), thermocouples, PT100/1000, as well as IEPE sensors and voltage signals.
-
product
Multi-Channel Telemetry
The AT7000 multi-channel systems can combine any customized mix of ordinary sensors: strain gages, thermocouples, RTDs, accelerometers, as well as motor/generator field voltages, currents and ground fault currents. The received data is continuously streamed to the user as analog (+/- 10V or 4/20mA) or digital data.
-
product
Analog Input Products
Analog input boards are useful for measuring variably changing conditions in the real world. When we want to measure these variably changing conditions, we need analog inputs to convert these changing real world conditions to changing electrical quantities. For example, monitoring the temperature inside a wood kiln, or the water pressure on the output of a pump, or the heart rate of a medical patient. In each of these cases, you can use one of our analog input devices to convert the electrical data from a sensor or transducer into binary data that can then be used by your computer. The device that converts this data is known as an analog to digital converter (abbreviated ADC, A/D, or A to D). An analog input is a measurable electrical signal with a defined range. The analog input changes continuously in a definable manner in relation to the measured property. This data is very useful for process monitoring, process control, or simple monitoring / data collection and acquisition. ACCES' analog input boards amplify and multiplex input signals from thermocouples, strain gauges, accelerometers, photo sensors, flowmeters, RTDs, thermistors, voltage sources, millivolt sources, and current sources, just to name a few.
-
product
Load Monitoring Units (LMUs)
Magtrol's Load Monitoring Units are used for measuring load, force and weight from signals generated by strain gauge transducers. Specifically designed for use with Magtrol's Load Measuring Pins and Load-Force-Weight Sensors, the LMU Series provides excitation voltage while conditioning the bridge output signal. Each unit contains DIP-switches and jumpers for greater flexibility and complete adaptability
-
product
Ultimate AC Sensor
Our Ultimate AC Sensor is just that... the Ultimate in voltage detection. This sensor detects 50-1000 volts AC and features a visual and audio alert. Like all of our sensors, it does not react to static electricity and is designed for a CAT IV environment.
-
product
Bi-Directional Level Translator
IFB-10001
Easily connect Arduino or other 5V microcontrollers to ~3.3V sensors. Based on the TI TXB0108 auto-sensing, bi-directional level translator, this module provides access to all 8 channels of the TXB0108 and has a built-in 300mA LDO with 200mV max dropout voltage at full load. Regulated 3.3V output allows this single board to both interface withandpower 3.3V sensors. An important feature of this module is the ability to operate SPI and other digital lines (not including I2C) at high-speed, whereas the 'NXP level shifter' maxes out at 400kHz and resistor dividers fail much earlier. The TXB0108, integrated with the LP3981 LDO, provide a fast, reliable solution to mismatched interface voltages that exceeds the performance of other solutions.
-
product
USB-6525, 16-Channel, 60 V, 8 Solid-State Relays, 8 Inputs, Ch-to-Ch Isolated Digital I/O Device
779640-01
The USB-6525 is an industrial, bus-powered USB I/O device that can automate even the most demanding applications. The solid-state relay outputs are ideal for controlling pumps, valves, motors, and various other industrial actuators. The USB-6525 features channel-to-channel isolated digital inputs that you can use to read from industrial digital sensors, and eight solid-state relay outputs featuring 60 VDC/30 Vrms switching voltage and 500 mA per channel maximum switching current. Using programmable power-up states, you can configure the initial output states in software to ensure glitch-free, safe operations when connected to industrial actuators.
-
product
Weather Resistant Surge Protector for RS485 Control & 12VDC Power Lines
SP-RS485-12V-O
Ideal for applications such as video surveillance cameras and access control. Protects sensors running on 22 AWG 2-wire sensor cables or 12VDC power lines against the effects of electrostatic discharge, faulty wiring and lightning. RS485 protection: Stage 1 clamping voltage: ±90V; Stage 2 resistance: 3.3 Ohms; Stage 3 clamping voltage: ±7.5V. 12VDC power lines protection: Stage 1 clamping voltage: ±90V; Stage 2 current rating: 3A; Stage 3: 12V TVS (transient voltage suppression) diode. Screw terminal pairs for RS485 and 12VDC power lines protection. Will also protect two single ended data, analog or control lines. Impact and weather resistant enclosure with locking hinged cover.
-
product
PCI Express 16 Isolated Input Digital Interface (10-30V)
8006He
Optimized for sensing up to 24V inputs, the 8006He PCI Express digital I/O interface provides 16 optically isolated inputs for connection to devices including sensors, switches, pushbuttons, and other user inputs. The inputs can sense both AC and DC voltage while providing optical isolation, which eliminates spikes and surges present in industrial environments. The board is PCI Express X1 compliant and is compatible with any PCI Express slot.
-
product
16-Channel VME RTD/Resistance Input Module
V410
The V410 is a 6U VME module that provides sixteen independent analog inputs that may be used to read RTDs, thermistors, and other similar resistive sensors. It can also read cryogenic diodes. Users may set input range and adjust other settings at VMEbus speed, and depending on the range selected the microprocessor will do the necessary calculations and output voltage, resistance, or temperature. Temperature conversion is available for 100Ω and 1000Ω, series 385 and 392, platinum RTDs.
-
product
PXI-6232, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module
779618-01
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6232 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6232 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6232 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
product
PCI Express 16 Isolated Input Digital Interface (3-13V)
8006e
The 8006e PCI Express digital I/O interface provides 16 optically isolated inputs for connection to devices including sensors, switches, pushbuttons, and other user inputs. The inputs can sense both AC and DC voltage while providing optical isolation, which eliminates spikes and surges present in industrial environments. The board is PCI Express X1 compliant and is compatible with any PCI Express slot.
-
product
PXI-6233, 16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module
779620-01
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6233 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6233 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6233 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
product
Easy Connection Of IEPE Sensors To Voltage Input Measurement Devices
K- IEPE
Our K-IEPE module is designed to connect IEPE sensors to a voltage measurement device that normally cannot support IEPE sensors. The powered K-IEPE module simply enables IEPE sensors to be connected via the BNC terminals and will output the signal voltages to an analog measurement device.
-
product
AC Voltage Sensors
Continuously monitor single or three-phase power lines for over or under voltage conditions with DARE?s AC voltage sensors, voltage monitors, and voltage sensing relays. DARE?s complete line of AC Voltage Sensors will protect system equipment and circuitry from voltage that is hazardous or unsuitable for operation.
-
product
16-Channel RTD Signal Conditioning Card
ProDAQ 5821
The ProDAQ 5821 series of Signal Conditioning Cards is designed to interface with a variety of sensors, principally RTDs, Thermistors, Cryogenic Diodes and Voltage type sensors. Each version of the 5821 provides the capability of precise 4-wire measurement. In order to achieve this, a precise 500μA constant current source is provided per channel. The current source can be disabled on a per channel basis and is monitored to ensure that current is flowing. The value of the output current is stored on-board after calibration. In order to achieve the highest accuracy the output current may be automatically calibrated 'on-the-fly' using the ProDAQ 3416 24-bit Sigma-Delta ADC card and an on-board precision resistor.
-
product
Digital Insulation Tester
200M
Laxtronics Instruments & Controls Pvt. Ltd
Digital insulation tester Model No: DIT200M is designed to carry out electrical insulation measurement in delicate or sensitive electronic sensors, transducers, modules and assemblies with test voltage from 1 to 30 Volts DC, its short circuit current is less than 100uA. The instrument can measure Resistance from 1 Meg Ohm to 1000 Meg Ohms.
-
product
Analog Temperature Sensors
Analog Devices analog temperature sensors provide current or voltage output proportional to the absolute temperature with accuracies of up to ±1°C. Our diverse range of analog output temperatures sensors can be used in a broad range of applications with no need for external calibration, and with minimal signal conditioning/conversion circuitry. To better suit your varied design needs, our portfolio of temperature sensors are available in multiple package options.
-
product
Voltage Variable Attenuators
Voltage variable attenuators (VVAs) that offer up to 60 dB of attenuation across a broad range of frequencies from 400 MHz to 18 GHz. These voltage variable attenuators are frequently used in applications such as electronic warfare, instrumentation, point-to-point and point-to-multipoint radios, fiber optic and broadband telecom, microwave radio and VSAT, military radios, radar, ECM, SATCOM and sensors, and R&D.
-
product
Pump Back Gas Analyser
Rapidox SF6 6100
The Rapidox SF6 6100 Pump Back is the latest in fully-automatic gas analysers, designed for controlling and monitoring the quality of SF6 in medium & high voltage gas insulated electrical equipment. Exceptional accuracy and stability are provided when measuring the purity of SF6 gas, through specially selected sensors.
-
product
Current Sensors
Our current sensors were designed for a simple, customer-specific construction of niobium wire wound magnetometers, gradiometers or preamplifiers for small current or voltage signals.