Filter Results By:
Products
Applications
Manufacturers
Sound Chambers
Shielded rooms designed to attenuate sound.
See Also: Chambers, TEM Cells, Acoustic Chambers, Altitude Chambers, Anechoic Chambers, Climate Chambers, Dust Chambers, Environmental Chambers, ESS Chambers, Humidity Chambers, Refrigerated Chambers, Reverberation Chambers, RF Chambers, Salt Spray Chambers, Temperature Chambers, Temperature Humidity Chambers, Thermal Shock Chambers, Vacuum Chambers
- Canden Products LLC
product
Stability Testing Chamber - Double Door Model
Q20
Canden stability testing chamber is capable of maintaining stable temperature set points of 25°c , 30°c & 40°c and corresponding relative humidity set points of 60%RH(@25°c), 65%RH(@30°c) and 75% RH(@40°c) with exceptional precision. The chamber has a wide operating temperature range of 18°c t to 40°c maintaining a stable temperature across the entire range. This chamber provides outstanding stability testing performance for manufacturers of pharmaceuticals, biologics, food, and personal care products. Canden stability chambers’ performance meets ICH Q1A general case guidelines for pharmaceutical stability testing.
-
product
Production Line Acoustic Test Chamber
PLATC
The Production Line Acoustic Test Chamber from GRAS is designed for quick and qualified acoustic test of cell phones, tablet PCs, Bluetooth speaker systems etc., including frequency response, THD, Rub & Buzz and microphone test using optional sound source. The chamber has a number of connections for injecting test and control signals to the test object (DUT).Benefits include:Repeatable testing and reliable dataEasy open/close for quick and safe change of DUTFlexible test jig for easy adjustment to new DUTFlexible microphone mounting for both front/backside speakers as well as edge-mounted speakersHigh quality, high sensitive 1/4” CCP measurementmicrophone included (G.R.A.S. 46BL)Individually calibrated frequency response** Compared to reference measurement in anechoic room
-
product
Acoustic Control System
m+p VibControl performs acoustic testing in reverberation chambers and direct field environments as well as progressive wave tube testing. It is a fully automatic digital control system, providing fast, accurate and repeatable control of high-level noise to a reference octave band spectrum and the overall sound pressure level (OASPL). The control guarantees a high level of product safety.
-
product
Test Chambers
Anechoic
Free Field Test Chamber for sound pressure level measurement, sound power level determination, acoustic research and audio measurement applications
-
product
Acoustic Control
Acoustic Control provides accurate control for high-level noise testing of reverberant chambers or progressive wave tubes. Based on the Spider hardware platform, Acoustic Control achieves quick and reliable control of the noise level to the reference octave spectrum and the overall sound pressure level (OASPL). Included safety features guarantee the safety of the unit under test.
-
product
Ear Simulator
BO1028
The BO1028 Ear Simulator is a special coupler for microspeakers or earbuds that has been designed to be compliant with ATU-T P.57 and IEC 60318-1. While mics in our BP1090 couplers receive sound waves the way they travel through air, the dual compartment chamber of the BO1028 is designed to modify sound pressure so that the mic receives air vibrations the way a human ear drum would receive them.
-
product
Medium-size Reverberation Chamber
E-Series
The E medium-size multicavity Reverberation Chamber Series represents that state-of-the-art in reverberation chamber technology. The E-Series can make single measurements, batch tests, protocols or campaign tests for different frequency bands, different technologies and different channel models, running overnight without human intervention. Embedded frequency-, mode-, source- and platform-stirring in a double-shielded set of cavities allow Passive MIMO (Efficiency, Correlation, Diversity Gain, MIMO Capacity and others), Active MIMO OTA (TRP, TIS, TPUT, MTS, CQI, M2TxDT, RSRP, MCL and others) and Time-Domain MIMO (DL/UL TCP/UDP TPUT, RMS DS, STD, PL, CBW, Mute%, eNodeB, VDT-OTA) measurements up to 8x8 and 8DLCC to be performed for antennas and devices up to 50cm and 50kg ranging from 2G to 4G, covering all available cellular and wireless technologies to date, including wearables devices, sound acoustic mute, WLAN and W-IoT testing. There is no RC in the market more advanced than the E-Series.
-
product
Acoustic Test Chambers
Small Device Test Chambers are used for >Basic sound level measurement of small products and equipment >Pre-compliance testing of small products and equipment >End of line manufacturing test on small products and equipment Small Device Test Chambers provide acoustic isolation from outside sounds and/or reduce the sounds from the device under test radiating into the host
-
product
Anechoic Chambers
Eckel Noise Control Technologies
Anechoic Chambers are echo-free enclosures with a sound energy absorption level of 99% to 100%, or a reflected sound pressure level of 10% or less. The frequency at which the energy absorption drops below 99%, or the pressure reflection exceeds 10%, is known as the low-frequency cut-off. Sound absorption is obtained by lining the walls, ceilings, and floor with wedges or other sound absorbing elements or SuperSoft panels, depending on performance level required and cut-off desired.
-
product
Audio Testing
Sound Power testing is required in many international standards. Quest also offers a variety of additional acoustic tests and the design experience to help you develop quieter products for your customers. Our chamber is able to cancel out all outside forces as well with its free floating floor boards.
-
product
PDIV Tester for EV Motor
PDIV 500-T
Shanghai Dean Electrical Co., Ltd
Differing from partial discharge with high frequency pulse which produce sound and light phenomenon, the power frequency AC voltage reaches a certain threshold, can only produce instantaneous current leakage around the tested sample, it can be detected through discharge capacity (unit: PC) to evaluate partial discharge phenomena..The instrument PDIV 500-T is designed to put samples such as enameled wire, insulation paper/film, and electric motor stator in the High temperature / humidity environment chamber, applying a power frequency voltage with a programed rising speed, and prefect ground connection must be guaranteed , through the coupling capacitor as the medium, the continuous detection of discharge capacity against the voltages will create formulation between the Voltages and discharge capacities (pc), the software will find the discharge voltage threshold called PDIV.
-
product
Reverberation Chambers
Reverberant Test Chambers for sound power level determination and building acoustics measurements
-
product
Sound and Light Controlled Environment
SmartChamber
SmartChamber provides a sound isolated, ventilated and light controlled environment to perform high performance ultrasonic vocalization experiments. The chamber can be provided with a built-in Sonotrack ultrasonic microphone and has an interior which effectively removes sound echo's, external noise and sounds and magnetic fields. SmartChamber can be seamlessly integrated with our product Sonotrack
-
product
PXIe-4463, 51.2 kS/s, 2-Output PXI Sound and Vibration Module
783086-01
The PXIe‑4463 offers high dynamic range and THD+N for audio, acoustic, and vibration applications. It provides the high precision and dynamic range necessary for the most stringent audio generation requirements in a modular form … factor. The PXIe‑4463 contains two 24-bit digital‑to‑analog converters to allow for fully differential simultaneous generation. Complete with three gain ranges, the PXIe‑4463 can generate current with programmable, per channel output configurations. The two timing engines allow you to perform multisample-rate applications on a single module and independently start and stop channels on a single module.
-
product
PCI-4462, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 4-Input Sound and Vibration Device
779309-01
The PCI‑4462 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous four-channel dynamic signal acquisition with six programmable gain settings for making high-accuracy, frequency-domain measurements. The PCI‑4462 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications for dynamic signal acquisition devices include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.
-
product
PCI-4461, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 2-Input/2-Output Sound and Vibration Device
779307-01
The PCI‑4461 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous two-channel dynamic signal generation and simultaneous two-channel dynamic signal acquisition with six gain settings to configure the input range. The PCI‑4461 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.
-
product
PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module
781490-01
204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
product
PXIe-4463, 51.2 kS/s, 2-Output PXI Sound and Vibration Module
783086-02
51.2 kS/s, 2-Output PXI Sound and Vibration Module - The PXIe‑4463 offers high dynamic range and THD+N for audio, acoustic, and vibration applications. It provides the high precision and dynamic range necessary for the most stringent audio generation requirements in a modular form factor. The PXIe‑4463 contains two 24-bit digital‑to‑analog converters to allow for fully differential simultaneous generation. Complete with three gain ranges, the PXIe‑4463 can generate current with programmable, per channel output configurations. The two timing engines allow you to perform multisample-rate applications on a single module and independently start and stop channels on a single module.
-
product
Sound Meters
Is used for acoustic (sound that travels through air) measurements. It is commonly a hand-held instrument with a microphone.
-
product
Chambers
rf cham·ber ex·per·tise 1. the expert skill and know-how gained from designing and installing more than 10,000 rf chambers and enclosures worldwide 2. having the knowledge to answer questions others haven't thought to ask
-
product
Sound Dosimeter
897
Designed for conducting personal noise surveys, the 897 Dosimeter is versatile enough for the experienced hygienist but simple enough for the novice technician. The data storage feature allows you to view reports on the computer or print them for use later during inspections. Purchase the 897 by itself or in the SMS-2 kit with all of the relevant accessories, including calibrator, nose cone, microphone clip, wind screen, and serial and parallel printer cables.
-
product
Sound Meter
4431
The Kanomax Sound Meter – Model 4431-1G is the world’s first 0-dB function sound meter available. It is designed to meet Type 2 standards for ANSI S1.4 1983 and IEC 61672-1. The magnetic accelerometer easily attaches to machinery for increased accuracy and precise operation.
-
product
Sound Level Meter
3M SE-402 | VP 185057
Maschinenbau Haldenwang GmbH & Co. KG.
The 3M SE-402 of quality class 2 is the ideal sound level measuring device for almost every acoustical environment. The frequency weighting can be done according to the characteristics A, C and Z and the time weighting can be set to 'Fast' or 'Slow'. Ergonomically arranged buttons and the clear digital display (resolution 0.1 dB) ensure a high level of user-friendliness.
-
product
Reverberation Chambers
Over the past several decades, RCs have been enjoying growing popularity as a promising facility for the characterization of wireless devices and for EMC testing. The RC (Reverberation Chamber) measurement method exhibits much competitive superiority over the AC (Anechoic Chamber) method and TEM Cell method, such as low cost, enhanced test repeatability, a more realistic test environment, and easily achieved high-field environment. The application of the RC for performing EMC testing was first proposed by H. A. Mendes in 1968. In the recent IEC 61000-4-21 standard, the importance of EMC testing using RCs as an alternative measurement technique has been recognized.
-
product
Omnidirectional Sound Source
OmniPower
OmniPower Type 4292-L is an omnidirectional sound source, intended to be used in acoustical measurements for which a uniform spherical sound radiation is required.OmniPower complies to the ISO 3382, ISO 140 and DIN 52210 standards, and is used in both room acoustics and building acoustics applications.
-
product
Sound Level Meters
Is designed to respond to sound in the same way as the human ear and to give reproducible measurements of sound pressure levels.
-
product
Sound Level Meter
AWA5688
Hangzhou Aihua Instruments Co., Ltd.
* A handhold noise measuring instrument*. Multifunction and user- friendly sound level meter(sound level meter, integrating SLM, 1/1 OCT, 1/3 OCT analyzer, FFT analyzer, Noise dosimeter)* 240×320 color screen* Measurement range up to 133dB* Synchronously do integrating measure, statistical, real-time 1/1 OCT, 1/3 OCT, FFT analysis and noise dosimeter measure* Comply with IEC 61672 Class 2 and IEC61260 Class 2 and IEC 61252
-
product
Near-field Chambers
Most antenna measurements need to be carried out in the far field; that is, the test antenna should be illuminated by a plane wave. Typically this is carried out by providing sufficient separation between the source and the AUT so the spherical wave approaches a plane-wave character.Near-Field chambers are an excellent alternative to traditional far-field ranges; testing that can be accomplished on a far-field range can be accomplished on a Near-Field test range. This method of testing allows an operator to employ an indoor anechoic test chamber at a reasonable cost and avoid the problems associated with weather and security concerns often encountered when using an outdoor test range.
-
product
Sound Meters
Sper Scientific sound meters include all the features and functions needed for basic noise level surveys or to meet the requirements for OSHA compliance, community noise ordinances or machine noise evaluation. These sound meters are used by: Industrial Hygienists, Sound Engineers, Construction Engineers, Municipal Code Enforcement officials, Industrial Quality Control, Environmental Scientists, and many more.
-
product
Sound Level Indicators
A sound level meter is a measuring instrument used to assess noise or sound levels by measuring sound pressure. Often referred to as a sound pressure level (SPL) meter, decibel (dB) meter, noise meter or noise dosimeter, a sound level meter uses a microphone to capture sound. The sound is then evaluated within the sound level meter and acoustic measurement values are shown on the display of the sound level meter. The most common unit of acoustic measurement for sound is the decibel (dB); however, some sound level meter devices also determine the equivalent continuous sound level (Leq) and other acoustic parameters. With a portable sound level meter, industrial hygiene and workplace safety professionals can measure sound levels in multiple locations to ensure environmental conditions fall within recommended exposure limits (RELs). Some sound level meter devices can be permanently installed for continuous monitoring of sound levels at a work or job site.An important attribute to consider when searching for a suitable sound level meter is its type or class. The type or class of a sound level meter defines the device's accuracy as per American National Standards Institute (ANSI) or International Electrotechnical Commission (IEC) guidelines. Typically, "type" is the grade according to the ANSI S1.4 standard, whereas "class" is the grade according to the IEC 61672 standard. There are two types or classes assigned to sound level meters: type 1 / class 1 or type 2 / class 2. For assessing noise in basic industrial, commercial, educational, recreational or residential applications, a type 2 / class 2 sound level meter usually will suffice. For precision-grade assessments often made in a laboratory, a type 1 / class 1 sound level meter primarily is used. PCE sound level meter products are lightweight, easy-to-use and manufactured in accordance with the highest industrial standards.