Filter Results By:
Products
Applications
Manufacturers
- CAMI Research Inc.
product
4-Wire Resistance Measurement | Continuity & HiPot Cable & Wire Harness Testers
An add-on option for the CableEye HVX high voltage cable tester series that permits expanded testing for contact and wire resistance as low as 1 mΩ. After checking for opens, shorts, miswires, and resistance limits, the 4-wire Kelvin measurement applies a user-selectable test current from 10 mA to 1 A to determine connection resistance within 1 mΩ. The resistance profile of a model cable may be stored and used as a basis of comparison during later testing to reveal cold solder joints, faulty crimps, recessed pins, pin contact contamination, improper wire gauge, and stress-extruded wire.This option may be purchased with any new HVX tester, or added as an upgrade to any of your existing HVX testers.
-
product
Decade Resistance Substituter Lab Standard
HARS-LX Series
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.
-
product
Power Line Purpose Tester
LX-221A+
Shenzhen Lian Xin Technology Co., Ltd.
·Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards .·Used to test single – ends ,double –ends ,three-ends power supply cords.·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,·Provide with RS 232 interfaces, can communicate with PC, easy to upgrade,·Provide personalized customization according to different requirements.
-
product
Footwear Testing Machines
Dongguan Amade Instruments Technology Co., Ltd
Footwear testing machines are designed to determine a variety of mechanical and chemical performances of different types of shoe materials and finished shoes including sneakers, high-heeled shoes, leather shoes, casual shoes, etc. There are appearance performance tests including yellow resistance test, ageing resistance test, fastness resistance test, etc, physical performance tests containing flexing resistance test, rubbing resistance test, anti-slip test, etc, biological and chemical performance tests covering PH test, Formaldehyde content test, flame retardant test, etc, and service life test. Applicable to standards of ISO20344, SATRA, ASTM, etc.
-
product
Single, Double Power Cord Tester
LX-30A+
Shenzhen Lian Xin Technology Co., Ltd.
Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards ..·used to test single – ends ,double –ends ,three-ends power supply cords..·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,.·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,
-
product
Alternate 0.99 (28.00) - 6.00 (170.00) Long Travel Bead Probe
BPLT-25C-6
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
Resistance Meter - Portable, Precision Resistance Measurement from 0.10 to 1.00 x 10^12 Ohms
PRS-812B
- Wide Range Resistance: 0.10 Ω to 1.00x1012 Ω- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Constant Test voltages 10V and 100V for specification measurements to meet international and domestic ESD measurement standards- Auto Resistance Range Control- Auto Test Voltage Control- Uses a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- 120 Data Set Internal Memory- Uses Standard USB Cable for Charging- Charges in 2 Hours- 2-year Limited Warranty on Main Instrument
-
product
Resistance Standards
Ohm-Labs manufactures reference grade resistance standards from 10 micro-ohms to 10 teraohms. Each range of standards utilizes the latest advances in materials and processing for high stability and immunity from changes in ambient environment. All products are supplied with ISO17025 accredited calibration.
-
product
Multifunction Electrical Installations Meter
MPI-520S
The MPI-520S multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520S is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.
-
product
3 Wire (Digital) Earth Resistance Tester
2120 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The test leads are supplied as standard accessories for simplified two-wire measuring system.● 0Ω adjustment.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.
-
product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Physical
This category covers test equipment for verification of resistance to heat, fire, tracking, mechanical stress, endurance, impact, force, torque, dimensional accuracy & similar related parameters as required by national and international safety regulatory agencies. These equipment are used to check Electrical WiringAccessories, Electrical Home Appliances, Industrial Luminaires, Motors and components or parts used in such products. Many of these test equipment are common to many standards and are essential for routine test purposes.
-
product
British Pendulum Skid Tester
SG-BM-II
The instrument which is direct reading, gives a measure of the friction between a rubber slider and wet road surface. It provides the Highway Engineer with a practical means of obtaining reliable scientific evidence on which to take the appropriate measures to reduce skidding.It also can be used for testing slip resistance of floors and sports surfaces.Satisfies the following standards: EN 13036-4 EN 1097-8, ASTM E103, and BS812: 114, NLT 174, CNR No 105, 140 & Australian Standard (AS3661.1: 1993).
-
product
Digital Multimeter
DMM
Is a test tool used to measure two or more electrical values—principally voltage (volts), current (amps) and resistance (ohms). It is a standard diagnostic tool for technicians in the electrical/electronic industries.
-
product
Insulation Resistance Tester
UDH-50-1-T
UDEYRAJ ELECTRICALS PRIVATE LIMITED
utomatic-microcontroller operated• Standard test voltages-0.5kV, 1kV, 2.5kV, 5kV • Resistance range to 1TΩ • Continuous digital display on LCM• Test modes: Insulation resistance,PI (Polarization Index)AR (Dielectric Absorption Ratio)(PI and AR automatically calculated)
-
product
Ultra High 1.16 (33.00) - 9.70 (275.00) Long Travel Bead Probe
BPLT-25HF-9.7
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
Air Based Resistance
Air Based Resistance Standards are designed for high accuracy resistance calibration in air.
-
product
10:1, 10 Mohm, 300 MHz Passive Probe
PP016
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25C-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
Insulation Meters
Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.
-
product
High 1.50 (43.00) - 9.60 (272.00) Long Travel Bead Probe
BPLT-1C-9.6
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
product
Capacitance Bridge
1621
The GenRad1621 Capacitance Measurement system is a completely self-contained system capable of capacitance measurements in increments as small as 0.1 aF (10-4 pF) and conductance measurements in increments as small as 100 aU (10-7 U; equivalent to a shunt resistance of 1010 M). Measurements are three terminal, with 2- or 3-terminal connection, and provision is also made for the connection of an external standard for comparison measurements.
-
product
Resistance Software
OhmRef
OhmRef provides the power of automation for Standards maintaining statistical control of resistance values in your laboratory. This program controls a Low Thermal Scanner along with other equipment commonly available in Standards Laboratories to compare resistance standards over the range of 100µΩ to 10GΩ . Comparison accuracies arebetter than 1 ppm in the midranges.
-
product
Ohmmeter
PDRM-10A
The PDRM-10 A ohmmeter, with a range of 0.01µΩ to 200 Ω is currently the most accurate and highest resolution ohmmeter on the market, and at only 860 g it is also the lightest and most compact. All this has made it the standard low resistance ohmmeter in many electrical companies, industries and assembly companies. It has a resolution of 0.01µΩ.
-
product
Precision Thermometer
F252
ASL's F252 provides high accuracy, dual channel temperature measurement with Platinum Resistance Thermometers - PRTs - and uses AC bridge technology as developed by ASL for Standards Laboratories throughout the world. Model F252 requires no regular recalibration, the AC circuit techniques eliminating thermal EMFs and drift, while providing excellent long term stability. Front panel data entry allows you to enter probe calibration data into the F252's memory, so that thermometer resistance can be accurately converted to temperature in C, F or K. This can be password protected to prohibit unauthorised or accidental data entry.
-
product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1HL-4.5
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
product
Continuous LPR Corrosion Meter
MS2001L
The MS2001L is a microprocessor-based, field-mountable corrosion rate meter. This versatile instrument measures the instantaneous corrosion rate and electrochemical current between the electrodes of any standard 2-electrode linear polarization resistance (LPR) probe. Corrosion rate is displayed on the LCD display.
-
product
IEC60669 Pendulum Impact Tester
CX-BC2
Shenzhen Chuangxin Instruments Co., Ltd.
This Pendulum Impact Test Device Conforms to the standard GB2099.1, GB16915.1 and IEC60669, IEC60670 standard. To check the impact resistance performance of plug and socket electrical accessory's enclosure.
-
product
Clamp Meters
The clamp meter is ideal for measuring AC or DC voltage. The instrument is irreplaceable for inspection work and maintenance in various industrial applications, in research and development, in residential applications and in many small businesses or households. The PCE line of clamp meter is made according to the highest industry standards and very important: PCE offers instruments that are usable in all workspaces (equipped with very small or even very large jaws), the results are reliable and the clamps are easy to use. Every clamp meter is manufacturer calibrated and can be certified to ISO or NIST - hold a PCE clamp meter in your hands and you can feel the quality immediately.PCE offers a variety of models: Voltage detector, voltage leak detector, voltage power detector, metric detector and current detector. In addition many clamp meters are able to measure other parameters, such as capacity, resistance and power - power through clamps directly or by handheld digital instruments with external clamps (with a range of one or three stages). Very often the clamp meter is a real multimeter - so it becomes a general electrical measurement tool.
-
product
Hydrostatic Head Tester
TESTEX Testing Equipment Systems Ltd.
Hydrostatic Head Tester, used for determining the resistance of fabrics (canvas, coated fabrics, cover cloth, rainproof clothing fabrics and geotextile materials) and films to water penetration under pressure while firmly clamped in the test rig of standard area, by means of dynamic test method and static test method.