Filter Results By:
Products
Applications
Manufacturers
Reflectance
fraction of the electromagnetic energy.reflected.
-
product
Reflectance Standards
STAN Series
Ocean Optics offers specular reflectance standards for measuring shiny surfaces such as machined metals and semiconductor materials and low-reflectivity surfaces such as anti-reflective coatings and thin film coatings. The STAN-SSH varies in reflectivity from 87%-98% over the 200-2500 nm wavelength range and is available in a version (STAN-SSH-NIST) calibrated to a NIST master standard. The NIST calibration data range is 250-2500 nm.
-
product
Red Tide Spectrometers
USB-650
USB-650 Red Tide spectrometers are ideal for teaching about UV and visible absorbance, reflectance and emission applications. They are preconfigured, ready-to-use spectrometers that come in several different options. Fully integrated – USB650-UV-VIS and USB650-VIS-NIR models are preconfigured, ready-to-use systems.
-
product
Flatness Mirror
10773A
The Keysight 10773A Flatness Mirror is a 100% reflectance mirror that turns the direction of an incoming laser beam 90 degrees. The mirror, used in the 5530 Laser Calibration System, measures flatness in applications such as surface plate calibration. It can be used in place of the 10707A Beam Bender (6 mm or less beam diameter) for applications that require the larger aperture of the 10773A.
-
product
Gloss & Reflectance
Visual appearance can determine a person’s perception of a product. Colour and Gloss are two key parameters that are used to define a product’s overall quality. Perception is subjective, but Elcometer’s range of gloss meters, DOI meters and colour assessment equipment can quantify appearance measurement. The ability of a surface to reflect light without scattering is known as gloss. Using a gloss meter, gloss is measured by directing a constant intensity light beam at a fixed angle to the test surface and then by monitoring the amount of reflected light at the same angle. Different surfaces require different reflective angles.
-
product
Transmission / Reflection Measurement
Measure spectral transmittance and reflectance of optical elements such as lens, plate glass, filter, reflector, prism and so on.The wavelength range is 350 to 1100 nm as standard and 220 to 2000 nm as an option.Reflection measurement of a general spectrophotometer can only measure several types of fixed angles, but in this device the incident angle of the sample at the time of reflectance measurement is variable at an arbitrary angle and the minimum incident angle at reflectance measurement is 15 ° ( Optical axis angle 30 °) can be set up.
-
product
Radiative Transfer Numerical Model
HydroLight
The HydroLight radiative transfer numerical model computes radiance distributions and related quantities (irradiances, reflectances, diffuse attenuation functions, etc.) in any water body.
-
product
Integrating Sphere with Side Assistant Opening
IS-*MA**P/IS-*MA**C
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant Opening in A Molding Technology to meet the requirements.• Painting material of integrating spheres is according to CIE Pub.No.84 (1989) • The painting material is BaSO4 coating: ρ (λ) ≥0.96 (450nm~800nm) and ρ (λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12 tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp be tested up and down in the sphere. • Power Cable, Power Terminal and Auxiliary lamp position has been built-in (Auxiliary lamp is option). • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • Ordering Code: IS-1.5MA55P or IS-1.5MA55C (Φ1.5m, IS-1.5MA55P means square side opening is 0.5×0.5m, IS-1.5MA55C means cycle side opening diameter is 0.5m). IS-1.75MA66P or IS-1.75M66C (Φ1.75m and side opening is 0.6m). IS-2.0MA77P or IS-2.0MA77C (Φ2.0m and side opening is 0.7m). • Other size such as diameter 2.5m, 3.0m can be special order according to customer’s request
-
product
Conformance Calibration Standard Test Card for ISO/IEC Data Matrix and GS1 DataMatrix Symbol Verifiers
AI-CCS-DM-G Rev A
This precision 2D barcode Conformance Calibration Standard Test Card is the first 2D test card to provide ALL 12 of the Primary Reference Symbols specified by ISO 15426-2 for barcode verifiers. They are sized from 0.5mm to 0.2mm so that all the symbol sizes specified in Annex A.3.1 can be tested. Symbols 1-4 are GS1 DataMatrix symbols, while symbols 5-12 are ISO/IEC Data Matrix symbols consistent with the ISO/IEC 16022 standard. The card also includes four calibrated reflectance patches.
-
product
Loaded Spectrophotometer
DSCD-900
DSCD-900 is a highly performance spectrophotometer with test caliber upward. The instrument adopts the geometric conditions of D/8 lighting and observation of CIE recommendations, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, spectral reflectance standard deviation within 0.08, maximum of colorimetric values ΔE*ab is 0.03, to provide all the necessary color formula. It could be widely used for coating, printing, textile, meet plastic, food, medicine, automobile field to meet customers’ measurement requirement.
-
product
Spectroscopic Reflectometry
Measure reflectance of flat or curved samples with smooth or rough surface.
-
product
Diffuse Reflectance Sphere
DRS100
Mobile displays are used in a variety of ambient lighting environments. The evaluation of mobile displays under diffuse illumination conditions is critical to the understanding of display performance in the real world, as mobile displays are used in a wide range of ambient lighting environments. The DRS100 is purpose-made to completely characterize the diffuse reflectance properties of mobile displays, providing uniform hemispherical illumination.
-
product
GLORIA-X150A/ Xenon Light Source
Xe arc lamp light sources are the preferred artificial sources to simulate sunlight. The high color temperature (6000K) of the Xenon lamps is a close match to the solar temperature. This results in very similar solar spectra in the UV and VIS although the source has some Xe emissions lines in the near IR. Application for fluorescence, luminescence and phosphorescence, absorbance and reflectance, photochemistry, photolithography, solar simulation and so on.ct description goes here.
-
product
Thin Film Metrology Systems
Gemini Series
The n&k Gemini-TF, Gemini-TF-M and Gemini-FPD are specifically designed for measurements of patterned and unpatterned films on transparent or opaque substrates. These tools are used extensively for solar cell, flat panel and photomask applications. The tools belonging to the Gemini-TF Series are based on unpolarized Reflectance (R) and unpolarized Transmittance (T) measurements, with a 50μm spot size for both R and T. R and T are simultaneously measured to determine film thickness and n and k spectra from 190nm – 1000nm
-
product
Glossmeter
480
Quickly and accurately measure and record Gloss, % Reflectance & Haze measurements on a wide range of materials, including paint, plastic, ceramic or metal with the Elcometer 480 Glossmeter.
-
product
DOI / Haze Meter
807
TRICOR’s Hazer Meter and DOI is ideally suited for measuring flat, non-textured high reflectance surfaces. The Model 807A Haze Meter design is in accordance with ASTM E430 and ASTM D5767 (method A) and is used to measure ±3 degrees around the specular lobe centered at 30 degrees in approximately 220 increments. That’s an angular sample size of 1 sample per 1.6 minutes of arc! This allows differentiation between samples with very small differences in reflectance characteristics. Verified replacement for the older Hunter Dorigon II haze meter unit.
-
product
Bar Code Verifier
TP140B Report Printer
The TP140B Report printer allows for printing of inspection reports from your Inspector series bar code verifier. The printer provides a simple report that will have a line for each bar code inspected. Note: The Verifier Computer Interface Report (VCIR) is required if you need the Scan Reflectance Profile (SRP).
-
product
Hybrid Diffuse Reflectance Spectrometer
Poly602™
Solar Light has developed the fastest performing DRS instruments on the market, keeping product research, formulation and clinical testing in mind. HDRSplus™ software is designed specifically for a clinical testing laboratory environment and simplifies all HDRS calculations.
-
product
Xenon Illuminator
Luzchem's Xenon Illuminator was recently developed for use with photovoltaic cells. It is also being used with Luzchem’s transient absorption laser flash photolysis and time-resolved diffuse reflectance systems. Customers can expect the Xenon Illuminator to be useful for a wide range of spectroscopy applications including photovoltaic testing, laser photolysis monitoring, UV exposure, and as a microscopy light source.
-
product
Fiber Optic Measurement Systems & Sensors
MTI Instruments offers large measurement range and standoff distance fiber-optic measurement sensors and probes that provide ultra sensitive linear output response. Our modular (interchangeable) non-contact fiber optic sensors systems have dual channel that enables the user to make simultaneous measurements. Our fiber optic probes are designed to automatically compensate large changes in reflectivity making it possible to monitor dynamic reflectance of up to 100:1 making it ideal for measuring vibration of ultrasonic horns, modal analysis of disk drive suspension, displacement and timing of fuel injectors and lateral motion measurements.
-
product
Retro-Reflectometer
The visibility is an important factor for road markings, traffic signs, road studs as well as high-visibility material such as warning clothes and Heavy good vehicles (HGV's) contour safety marking.The measurement of retroreflectivity is essentially a measurement of the reflectance of material under specified geometrical and spectral conditions. Instruments are available for measuring the retroreflectivity of various reflection materials.
-
product
Flatness Accessory Kit
55282A
The 55282A Flatness Accessory Kit is composed of an 10759A Footspacing Kit and two 10773A Flatness Mirrors. The footspacing kit provides three precision baseplates, with 50.8 mm (2 in), 101.6 mm (4 in), and 152.4 mm (6 in) pad spacing respectively, that minimize the grid setup and data accumulation time required for plate calibration. The flatness mirrors provide 100 percent reflectance and turn the direction of an incoming laser beam 90 degrees.
-
product
kSA Emissometer
The kSA Emissometer is designed to quickly and easily generate high-resolution diffuse and specular reflectance and total emissivity maps of MOCVD carriers. Carrier emissivity variation means temperature non-uniformity, which can lead to reduced device yield and possibly complete growth run failure. With the kSA Emissometer, emissivity changes can be tracked to determine carrier end-of-life, without wasting growth runs. The kSA Emissometer also detects unwanted residual deposits after baking, and easily identifies carrier surface defects, scratches, microcracks and pits that are not visible to the eye.
-
product
Optical Switch
FTBx-9150
With crosstalk of –80 dB and life expectancy of 10 million cycles, the FTBx-9150 Optical Switch is ideal for bidirectional component testing, ribbon fiber testing, multichannel monitoring, remote and multiple-component testing, signal routing and bypass switching. Housed in the LTB-8-based test systems, the FTBx-9150 provides highly accurate and repeatable fiber-to-fiber switching. It offers a choice of 1x2, 1x4, 1x8, 1x12, 1x16, 1x24, 1x32, 2x2 and 2x4 configurations. Designed for minimal reflectance, the switches integrate precision optical components into a compact modular package. Both singlemode and multimode versions are available and offer a solution for all your optical switching needs.
-
product
UV-Vis Double Beam Research Spectrophotometer
UVD-3400
UVD-3400 has an excellent performance blazed holographic grating optimized and optional reflectance attachment CT-type Monochromator and reduces stray light and widen the photometric range. Wavelength range: 190 nm – 900 nm ; Spectral bandwidth: 2nm
-
product
Bare Fiber Aligner
1120
The Photon Kinetics 1120 Bare Fiber Aligner makes it possible to reduce test setup time to seconds, thereby reducing overall testing cost. Just strip the fiber, scribe and break it (or use a more precise fiber cleaver, if desired) and then insert the prepared end into the 1120. In an instant, the fiber is coupled to your OTDR or chromatic dispersion test system with low optical loss and low reflectance. The 1120's compact, ergonomic industrial design is well-suited for low to moderate volume fiber and cable testing applications where automated fiber alignment systems are less economical. It is particularly useful as part of an in-process or finished cable test station employing either the 8000i or 8000 OTDR, and the OASYS.net OTDR Automation Software.
-
product
Turning Mirror
10772A
The Keysight 10772A Turning Mirror is a 100% reflectance mirror that turns the direction of an incoming laser beam 90 degrees. The mirror is used in the 5530 Laser Calibration System for applications such as machine tool calibration. It can be used in place of the 10707A Beam Bender (6 mm or less beam diameter) for applications that require the larger aperture of the 10772A.
-
product
Scatterometers/ Thin Film Metrology Systems
LittleFoot Series
The n&k LittleFoot-CD, and LittleFoot-CD450 are DUV-Vis-NIR scatterometers/thin film metrology systems, based on polarized reflectance measurements (Rs and Rp) from 190nm to 1000nm, with microspot technology. The systems in the LittleFoot-CD Series determine thickness, n and k spectra from 190nm-1000nm of thin films, as well as depths, CDs, and profiles of trenches and contact holes.
-
product
Reflectance/Transmittance Test Set
RT-500
An Integrating Sphere is a hollow sphere which has its interior coated with a paint that is nearly perfectly diffuse or Lambertian and which has extremely high reflectance. Light energy introduced in an integrating sphere is reflected from the wall and distributed uniformly around the interior. A detector which is placed at a hole or 'Port' in the sphere wall sees an output which is completely independent of the angularproperties of the input light. The independence of the output of a sphere from the angular properties of the input and the uniform internal distribution of light make integrating spheres ideal for many uses.
-
product
Reflection/Transmission Test Chamber
CHTR-100
When measure the surface spectral reflectance of all kinds of reflect mirror, metal, plastic and so on or the spectral transmission of glass and plastic, CHTR-100 Reflection/Transmission Test Chamber is mainly used to collect photometric and chroma energy, and then send the tested light signal to spectrometer or reflection and transmission photometer to get the color parameters via optical fiber or photoelectric detector.
-
product
Lens Measurement Spectrophotometers
LINZA 150
LINZA 150 spectrophotometer is designed for broadband transmittance and reflectance measurement of lenses and lens assemblies (objectives) ensuring that only perfect lenses are approved for lens assemblies, delivered to customers or meet specs provided to your lens supplier. The instrument is perfectly suited for both routine lens measurements and sophisticated improvement of lens production technology: Fast on-axis transmittance measurement of individual convex/concave lenses. Fast on-axis transmittance measurement of lens assemblies (objectives). Unattended on-axis and off-axis reflectance measurement of individual lenses providing measurement data virtually from any area on lens surface (both convex and concave). Ideal for fine-tuning of deposition technology used to produce coatings on lenses.