Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI Source Switching Module
40-618-001
The 40-618 PXI Source Switching Module consists of 12 separate 4-channel multiplexers and 44 uncommitted SPST relay contacts in a single width PXI module. Typical applications include signal routing for avionics test systems that conform to the ARINC 608A specification.
-
product
Mode Locked Synthesizer
IT9200
The ITS-9200 is a synthesized RF source with a flexible locking capability that allows it to be phase-locked to non-standard external references. It is specifically designed for synchronization to mode-locked lasers with pulse output frequencies in the 72-80 MHz region, although it can be easily modified to adapt to other reference frequencies.
-
product
Reference Frequency Generator
MFCh
*Frequency reproduction accuracy ± 2 x 10 -9 *Output frequency 1 Hz - 10 MHz *Output pulse signal 1 kHz The MFC is designed to generate high-frequency pulse signals with a frequency of 1 kHz and a frequency in the range from 1 Hz to 10 MHz along two output lines. The MFC is designed to operate in measuring systems based on the VXIbus trunk. In the MFC, a rubidium frequency standard is used as a reference frequency source. Time to reach the mode when the power source of the rubidium standard is turned on, no more than 10 min
-
product
4-Channel ADC Module
FMC104
Sundance Multiprocessor Technology Ltd.
The FMC104 is a four-channel ADC FMC (FPGA Mezzanine Card) which is fully compliant with the VITA 57.1-2010 standard. The FMC104 card provides four 14-bit 250 MSPS A/D channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available.
-
product
Blackbody System
IR-574/301
Infrared Systems Development Corp.
The IR-574 Series blackbody reference sources are designed to provide infrared radiation as an ideal blackbody emitter. The output energy from the 2.25" Cavity closely follows the theoretical maximum energy curve described by Max Planck's equation, and allow users to calibrate, align, and measure infrared devices and phenoma of all types.
-
product
12-Channel ADC Module
FMC112
Sundance Multiprocessor Technology Ltd.
The FMC112 is a twelve-channel ADC FMC Daughter Card which is fully compliant with the VITA 57.1-2008 standard. The FMC112 provides twelve A/D 14-bit 125Msps channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC112 has the LPC (Low-Pin Count) connector, front panel I/O, and is conduction cooled capable.
-
product
16-Channel DAC FMC Module
FMC216 – HPC
Sundance Multiprocessor Technology Ltd.
The FMC216 is a sixteen-channel DAC FMC Daughter Card which is fully compliant with the VITA 57.1-2008 standard. The FMC216 provides sixteen D/A 16-bit 312.5Msps (2.5Gsps with x8 interpolation) channels which can be sampled by an internal clock source (optionally locked to an external reference) or an externally supplied sample clock. A trigger input for customized sampling control is also available. The FMC216 has the HPC (high-pin count) connector, front panel I/O, and is conduction cooled capable.
-
product
PXIe Frequency Reference: 10 MHz And 100 MHz
M9300A
The M9300A PXIe frequency reference is a PXIe-compatible, compact, modular instrument that can be used with the Keysight M9301A synthesizer, M9310A source output, and M9311A modulator to create the world’s fastest vector signal generator, the M9381A. Create a CW source, the M9380A, by combining the M9300A with the M9301A and M9310A or use it as the 10-MHz or 100-MHz reference with other PXI solutions. Control the instrument through a soft front panel and programmatic interfaces tuned to your application development environment of choice.
-
product
4/8-CH 12-Bit 1 MS/s Analog Output Multi-Function PXI modules
PXI-2500 Series
ADLINIK PXI-2501 and PXI-2502 are high-speed, high-performance analog output multifunction PXI modules. These devices are able to update up to 8-CH, 12-bit analog outputs imultaneously sustaining 1 MS/s. The reference sources and output polarities are programmable individually per channel. Combine this with the multiplying PXI architecture, ADLINK PXI-2500 series PXI modules can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory. The PXI-2500 series integrate up to 8-CH, 400 kS/s, 14-bit single-ended analog inputs with programmable polarity, 24-CH programmable digital I/O lines, and 2-CH 16-bit general-purpose timer/counters.
-
product
IR Calibration Instruments
Bodkin Design & Engineering, llc
We offer a line of comprehensive solutions to address all of your thermal calibration needs. From bench-top differential sources with .01° C resolution for experiment calibration to built-in OEM devices for on-the-fly thermal reference, Bodkin Design and Engineering and IRBlackbody have the right blackbody for you.
-
product
Spectral Response SystemsQuantum Efficiency SystemsIPCE Measurement Systems
QE system provides electronics and software designed for fully automated measurement of external quantum efficiency of solar cells. All systems include probes and a fixed plate sample stage for samples up to 150 mm x 150 mm. The main system components include: custom designed software, measurement electronics, and computer system (Windows 8 operating system). The measurement involves focusing monochromatic light to a spot on the device under test, then accurately measuring the photon flux and current from the test cell. The system utilizes a dual beam configuration with lock-in detection, providing an absolute accuracy of ±3%. The QE system uses a grating monochrometer with silicon/InGaAs/Ge detectors. The system includes automatic order sorting filters and two light sources for monochromatic illumination (a Xenon- arc lamp and a halogen lamp). A single lock-in amplifier is used to measure both the reference detector and test device. The main system comes with all the hardware needed to measure quantum efficiency, a fixed plate sample stage and probes.
-
product
3U OpenVPX High Density Multifunction I/O Board
68CB6
The 68CB6 is a Configurable Open Systems Architecture™ (COSA®) 3U OpenVPX™ board that is preconfigured with 10 different “inboard” I/O, measurement and communication functions. This Combination-function Board (CB) provides a full suite of some of the most common & useful function interfaces supporting many different applications. The 68CB6 features a wide but dedicated selection of functions: Standard Functionality Discrete I/O (DT1); Successive Approximation Register (SAR) ±100 V Analog-to-Digital (AD); Isolated High Voltage Analog-to-Digital (ADF); ±10 V Digital-to-Analog (DA); Thermocouple (TC1) or Resistance Temperature Detector (RT1); Full-bridge Strain Gauge (SG1); Transmission/gear box Chip Detection and Fuzz Burn (CD1); LVDT-to-Digital linear (LD6) displacement (position) measurement, AC Reference Source output (AC2); CAN bus communication (CB8). The 68CB6 offers unparalleled programming flexibility, a wide range of operating characteristics, and a unique design that eliminates the need for external intermediate circuit considerations such as pull-up resistors or mechanical configuration jumpers. Inboard functions are software controlled and memory addressed, accessed in similar COSA® modular fashion to maintain seamless common NAI Software Support Kit & API/library structures.
-
product
IRIG Timecode Receiver and Generator
RG1
The RG1 Time Code receiver synchronizes to IRIG-A/B/G time codes and provides precise time in a memory register, for the host SBC.The IRIG output of the card can be used to synchronize other IRIG time code readers. Additionally, the RG1 includes a real-time clock (RTC) that may be used as a reference source for IRIG master applications, to free the system processor from the task of updating the master timer.
-
product
6GHz Dual Frequency Synthesizer moduleValon
5009
The Valon 5009 Dual Frequency Synthesizer module is our latest offering in high frequency synthesizer sources. These frequency synthesizers are perfect in applications that require a spectrally pure and highly stable signal source or timing clock. Our synthesizers have replaced laboratory generators costing many times more in a number of applications. Each module actually contains two independent sources locked to the same internal or external frequency reference or standard. Having two phase coherent sources in the same convenient package opens up a wide variety of test applications and solutions
-
product
Laser Heads
The laser head is the source of the laser beam used in all laser motion and position measurement systems. The primary difference between laser heads is in the velocity, reference frequency and optical output power. Other considerations are size, heat dissipation, and input power requirements. Which laser you choose depends primarily on the application in which it will be used. For example, semiconductor lithography systems typically have faster moving parts (stages), and therefore need higher velocities than machine tool applications.
-
product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model T360M
Teledyne Advanced Pollution Instrumentation
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.
-
product
Frequency Standard Products
The ES-110 generates a stable source of 10 MHz using GPS (Global Positioning System) satellites as a reference. If frequency distribution is needed, we offer the ES-210, a Quad 1x6 1/5/10 MHz Distribution Amplifier. The ES-210 provides four independent 1x6 Frequency DAs in a single rack-mount enclosure. The ES-410 is a four output version of the ES-110. The ES-410 was introduced and won Radio Magazine's Best of Show Award at the 2016 NAB Show.
-
product
Three-phase Fully Automatic Test System
TS41
Calmet Smart Calibration Devices
The Calmet TS41 test system consists of a three-phase reference meter of accuracy class 0.02% (or 0.04%) and an integrated three-phase current and voltage source up to 3x120A/600V. It makes possible automatic testing of electricity meters in meter test stations
-
product
10 MHz AGC Distribution Amplifier
FS710
Stanford Research Systems, Inc.
For installations which require many 10 MHz outputs at a remote location from the source, the FS710 AGC Distribution Amplifier offers seven independent outputs from one input. With an AGC circuit capable of adding up to 30 dB of gain, this amplifier can be used to provide a 10 MHz reference at locations as far as a mile from the source.
-
product
4-Channel DAC FMC Module
FMC204 – HPC
Sundance Multiprocessor Technology Ltd.
The FMC204 is a quad channel DAC FMC. The FMC204 provides four channels of 16-bit D/A @ 1 GSPS enabling simultaneous sampling at a maximum rate of 1 GSPS. The sample clock can be supplied externally through a coax connection or supplied by an internal clock source (optionally locked to an external reference). Additionally a trigger input for customized sampling control is available. The FMC204 daughter card is mechanically and electrically compliant to FMC standard (ANSI/VITA 57.1).
-
product
Comb Generator
CG01
The main application of Comb Generator is to quickly verify conducted emissions test setups. And the most important application is trouble shooting Open Area Test Sites(OATS).An OATS must be completely calibrated before it is put into service. reference signal source Noise Generators Signal Generators
-
product
Shunt Regulators
These are the standard reference voltage source widely used by the feedback circuits of switching power supplies. Compared to the Zener diode, which is a discrete product, a shunt regulator has much better voltage precision because voltage control is carried out as an IC.
-
product
Material Solutions
Leverage Altair’s material engineering, data organization, and consolidation expertise using the latest database technologies with Altair material solutions. Our material solutions use high-quality reference data and enables the consolidation of extensive proprietary material information intelligence into one secured private source. The solutions cover the processes to collect, prepare, create, share, collaborate, and consume material information from anywhere.
-
product
Coherent Modulation Transmitter
IQTX
Generating and controlling phase modulated optical signals is easy with the IQTX. The IQTX is referred to as a ‘Golden’ reference optical signal source because of its high repeatability and reliability.Its high bandwidth of 40 GHz ensures high quality optical signal generation, making it the ideal optical signal source for coherent communications applications.
-
product
PMC-Parallel-IO
PMC-Parallel-IO provides 64 independent IO in one PMC slot. 64 mA open drain buffers on each IO. Two interrupt sources. External or internal clock reference. Custom state machine designs.
-
product
Source Systems AC
The power sources of MTS-series based on digital amplifier modules combined with frequency generator and reference device are the MTS source system. Single-phase systems (MTS1xx) or three-phase systems (MTS3xx) from 1 to more than 40 test positions are available.
-
product
Temperature Monitors
SIM923A
Stanford Research Systems, Inc.
The SIM923A has selectable 10 µA and 1 mA current sources to provide sensor excitation. Sensor resistance is determined ratiometrically with a half-bridge circuit consisting of the sensor and an internal reference resistor.
-
product
4/8-CH 12-Bit 1 MS/s Analog Output Multi-Function PXI modules
PXI-2500 Series
ADLINIK PXI-2501 and PXI-2502 are high-speed, high-performance analog output multifunction PXI modules. These devices are able to update up to 8-CH, 12-bit analog outputs imultaneously sustaining 1 MS/s. The reference sources and output polarities are programmable individually per channel. Combine this with the multiplying PXI architecture, ADLINK PXI-2500 series PXI modules can generate complex modulated analog signals. The hardware-based arbitrary waveform generation frees CPU intervention even when all analog outputs are updating at full speed, and the lengths of waveforms are only limited by the system memory. The PXI-2500 series integrate up to 8-CH, 400 kS/s, 14-bit single-ended analog inputs with programmable polarity, 24-CH programmable digital I/O lines, and 2-CH 16-bit general-purpose timer/counters.
-
product
Ultra High Power Precision Shunt Resistor
UHPS
*Max. current limit 707A*Excellent short term stability*Low temperature coefficient of resistance (T.C.R.)*High current sensing & reference resistors in laboratories*Change - discharge test equipment for high capacity batteries*Current sources & laboratory power supplies
-
product
RF Reference Sources
The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.