Test a power source by providing controlled amounts of load to create conditions found in thier application.
See Also: AC Load Banks, DC Load Banks, Inductive Load Banks, Reactive Load Banks, Resistive Load Banks
- Pickering Interfaces Inc.
product
PXI 4 Banks of 16 Chan 1 Pole MUX
40-657-001-4/16/1
40-657 High Density Power Multiplexer Modules are available in a choice of configurations, containing up to 8 separate multiplexers, all 1-pole switching. They are suitable for switching signals to 110VDC/250VAC at 2Amps, 90W.
-
product
Load Banks
BD Series
*12 kW, 15kW and 18kW Battery Discharge Load DC*All of our Load Banks are continuously rated for Power and Current.
-
product
PXI 36 Channel Data Comms MUX, 96-pin SCSI
40-735-912
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. This 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
product
DC Load Banks
Custom DC Units
Mosebach Manufacturing Company
Mosebach has been building DC load banks for over 30 years. We have a wide range of custom-designed units. Please give us a call at 1-866-629-4328 to discuss your needs.
-
product
AC Load Banks
X60C Series
Mosebach Manufacturing Company
The X60C is a small suitcase style 60 kW load bank.
-
product
Uni-Therm High Current Electrosurgical Analyzer
A unique high power low inductance load bank enables performance testing up to 8 ampere RMS with a duty cycle of up to 100% making the analyzer an extremely versatile test instrument for calibrating and performance testing of conventional and high power electrosurgical generators. The load bank allows testing in a range of 0-5115 with a resolution of over 1000 steps providing high detailed power profiles. The Rigel Uni-Therm also advocates safe working practise by providing all necessary resistors within a single enclosure.
-
product
AC Load Banks
X250S Series
Mosebach Manufacturing Company
The X250S is the only one of its kind: 250 kW in a very small package. Light, portable; with digital meter and recording capability. Center lifting bar and casters are both available as options. Ideal for "Black Tests" in data centers as blowers are powered externally with 120VAC
-
product
Resistive & Capacitive, Inductive AC Load Bank
RLC
Inductive & capacitive load banks are reactive only and must be used in combination with a resistive load bank to provide the desired load profile to test a power system. Reactive loads banks can provide either a leading power factor (Capacitive) or lagging power factor (Inductive).
-
product
Automatic Power Factor Controller
Power factor controlling based on the capacitor bank switching historyCapacitor is automatically disabled when it is deteriorated beyond a certain levelAutomatically learns the number of capacitors connected and the value.Capacitance-based power factor correction takes care of variation in voltage and frequency.Controlling based on VAR parameter and availability of built-in alarms Flexibility for site programmability of CT ratio suitable for any load
-
product
Battery Testing System
C8000
The Cadex C8000 stands in a class by itself in flexibility and affordable price. Test SMBus batteries, monitor cell balance and capture load signatures to observe batteries with a unique load protocol. Add a thermal chamber, an external load bank, a safety circuit and alarm to form a command center and you begin realizing the unique qualities of this fine battery testing system.
-
product
PXI Single 10 Channel MUX, XLR Connectors
40-735-902-S2
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
product
Battery Load Banks
Kongter Test & Measurement Co., Limited
Kongter offers many different models of battery load units for real capacity test in various industries. With our customized solution, users of different applications will find their exact models as per their needs. With its optional DAC (Data Acquisition Case), you could easily monitor voltage of each cell on PC during battery discharge test.
-
product
Dc Load Bank
Highly reliable and durable new alloy resistor is used for the JUNXY DC load bank. It is thermal shrinkable and seal installed in the stainless steel pipe, whose surface with insulated heat sink. The resistor is moisture-proof, anti-corrosion, good heat dissipation, high insulation resistance, safe and reliable.
-
product
AC Load Bank (Rack Mounted)
K-1000 Rack Mounted
Kongter Test & Measurement Co., Limited
Rack mounted resistive load bank is widely used in data center to simulate electric loads and dissipation of IT systems. These load banks are controlled by sectional steps with customized setting. Users could set power and time as per their needs with easy operation.
-
product
Combined Load Banks
C-Series
C-series combined load banks are devices which contain resistive and reactive loads, apply the load to an electrical power source and dissipate the power of the electrical power.
-
product
Adjustable Load Banks
DSR-WB series
Power can be up to 20kW, depends on the resistance value and application- Support High Current up to 80A.- For some cases, can support 3 phase Rheostat application
-
product
Custom Load Banks
Power House Manufacturing, Inc.
Custom Load Banks are our specialty. Power House Manufacturing is dedicated to providing our customers with exactly what they need. Having years of custom load bank manufacturing experience, Power House can deliver the perfect custom testing solution you require.
-
product
Load Banks
Power Test Dynamometer offers a complete high capacity load testing solution with our load bank and gen set testing systems. Capable of testing generators and AC/DC power sources, our load bank systems safely apply electrical loads across the entire spectrum of operation. By offering a one-stop-shop for your Load Bank and it's accompanying data acquisition software, Power Test is committed to Making Your Testing Easy.
-
product
Capacitive Bank Load
Supreme Instrument Laboratories
Capacitive Bank Load Three phase suitable for operation on 415/440 volts three phase AC 50Hz housed in well ventilated sheet steel cabinet with bakelite front panel, complete with indicating lamps, voltmeter to indicate the input voltage and Ammeters to indicate, the load. ON/OFF switch, discharge switch etc. available in continuously variable type.
-
product
Multi-Unit Controllers
Mosebach Manufacturing Company
Mosebach’s Multi-Unit Controllers are built to help you manage your load banks in operation – whether 10, 20 or 500 units ganged together.
-
product
Load Bank
Being the reckoned names in the industry, we offer world-class range of Load Bank that is manufactured with perfection. We offer in different configurations such as Resistive, Inductive, and Capacitive. Our entire product range has high compressive strength and ensures smooth operations. They are durable in nature and are delivered in stipulated time frame.
-
product
Load Banks
Power House Manufacturing, Inc.
Load banks manufactured by Power House are engineered to be smaller and lighter than the competition.
-
product
Inductive Load Banks
L-Series
L-series inductive load banks are devices which contain inductive loads, apply the load to an electrical power source and dissipate the reactive power of the electrical source. L-series load banks are designed for portable and fixed applications. Hilkar brand L-series load banks have robust design and are specifically designed for corrosive environments. Load banks can be controlled via local, remote, wireless remote or automatic control systems.
-
product
Radiator Mounted Load Banks
RD-Series
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
product
AC Load Bank (Resistive)
K-1000 Resisitive
Kongter Test & Measurement Co., Limited
The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.
-
product
Portable Power Quality Analyzer
PDA 1252
The PDA 1252 is a portable power quality analyzer designed to monitor, isolate and troubleshoot power system disturbances. Using our advanced analysis software, the Communicator EXT application, view real time data presented in a simple and powerful format. Maximize the Communicator EXT application's power with the optional AiReports to generate disturbance solutions and advanced power reports. The unit is ideal for load surveys, program, monitoring transformer banks and indoor/outdoor electrical monitoring. The PDA 1252 Power Quality Analyzer is mounted in its own watertight carrying case and uses watertight connectors to connect voltage and current leads. Based on the Nexus 1252 platform, the PDA 1252 is easy to use and operate.
-
product
Variable Resistor Load Bank
REOLOAD 100
A variable resistor load-bank with fixed stages connected in parallel and switched in, as required, with an adjustable stage for fine trimming. Designed for testing equipment under load. 1000V (AC or DC). 250A and 2500
-
product
Locomotive Testing
DC7000
A purpose-built load bank for the performance testing of engines and generators of all types of diesel electric locomotive up to 4000hp rating, with easy-to-use resistance adjustments allowing tests to be carried out over the whole power envelope. Capacity 0 7000A continuously at up to 2000V DC
-
product
PXI Single 18 Channel MUX, BNC Connectors
40-735-902-S3
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
product
Battery Loading Unit
BLUe
BLUe series Battery Loading Units; portable instruments for controlled & monitored discharge of batteries. It is designed for integrated site discharge test, design & QC test and also for monitoring discharge process of battery bank with connected load. Single autonomous unit having inbuilt display, keypad and wireless communication with PC makes it very easy to use. It comes in different configurations ranging from 12V to 380V discharge voltages and 50A to 300A discharge currents. Various options are available to control & monitor the discharge process. With the help of optional Cell Monitoring Unit - CELLMon, voltage of each individual cell can be monitored & data sent to main BLUe unit and then from main unit to PC via wireless communication. Each BLUe unit is supplied with PC downloading & analysis software for real time monitoring of discharge process.
-
product
AC Load Banks
XL1000-XL1250 Series
Mosebach Manufacturing Company
The XL1000-XL1250 Series load banks offer you a continuous load at various voltages in a compact, lightweight enclosure.