Filter Results By:
Products
Applications
Manufacturers
Insulation Oil
measures the breakdown voltage of insulating oils.
-
product
High Voltage Relays
B-1001
Air insulated types for isolating loads, tap selections, safety discharge & grounding to help meet OSHA and other safety regulations. Ratings from 1mA to 800 amps continuous, to 100,000 amps capacitor discharge. Peak 1 minute test voltages from 5kV to 300kV. Single or Multipole. Auxiliary contacts are optional on all types. Options include latching, extended life, and tungsten contacts available for high current closing. DC, 25-800Hz & air pressure actuation available. Also usable in oil or insulating gas with increased ratings.
-
product
Transformer Oil Furan Analyzer
LC2010F
Chongqing Kailian Yongrun Industrial Co.,Ltd.
It is designed to analyze furaldehyde and related furan compounds in transformer oil and other mineral insulating oils.
-
product
Software
Delta-X
Delta-X provides software diagnostic solutions to assess and track the condition of electrical apparatus used by utilities and heavy industry. Delta-X’s Transformer Oil Analyst™ (TOA) is the market leading tool used by high-voltage equipment experts to manage and interpret insulating fluid test data, including dissolved gas analysis. Generation, transmission and distribution utilities, as well as leading industrial operations around the world, rely on Delta-X to provide accurate and timely insights into the condition of their high-value assets.
-
product
Pulse Holiday Detector
NOVOTEST SPARK-1
Pulse Holiday Detector NOVOTEST SPARK-1 designed to detect pits, flaws, and holes in different non-metallic insulation coatings (such as polymers, epoxy, bitumen, etc.) and is mostly used for oil and gas metal pipelines and other objects. The device can be used while the pipeline construction, operation or service. Tested coating thickness is up to 12 mm. Such tests are needed to evaluate the oil and gas pipelines corrosion protection reliability.
-
product
Insulating Oil Testing
Weshine Electric Manufacturing Co., Ltd
Weshine represent the absolute best in the field of transformer oil regeneration and corrosive sulfur removal. Several new features developed inhouse by our research and development department result in the state-of-the-art transformer oil regeneration equipment. Supplemented by our unique corrosive sulfur mitigation process integrated directly into the regeneration process.
-
product
Insulating Oil Tester / uP Operated
CU Series
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Fully automatic test cycle. Automatic change of sample number of test. Automatic calendar and time running even with power off.
-
product
High Current Switches
B-1002
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz. Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit. Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas. For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.
-
product
*High Current Switches
B-1002
Ross High Current Switches are available up to 36,000 amps continuous and over 1,700,000 amps 20µsec RC pulse, with voltage ratings of 6 volts to 400kV peak test. Standard Ross high current switches are built with 80 to 120psi air cylinder actuators. Air cylinder or motor operated for high contact force. Arcing contacts optional for closing current. G-10 epoxy glass laminate is standard insulation on most models. G-7 silicone glass is used on models available for RF applications above 100kHz. Most Ross high current switches are available with additional lengths of insulation, where the high voltage contacts need to be spaced at a greater distance from the actuator and control circuit. Voltage withstand value is at least doubled and the interrupt capability is much greater when high current switches are immersed in insulating oil, fluid or SF6 gas. For gas atmosphere, no modifications are necessary; however, oil or fluid immersion requires modification at a slight extra cost.
-
product
Automatic Transformer Oil Test Set With Printer
Oil Test is an equipment designed to test the dielectric strength of Insulating Oils as per relevant specifications vis. IS 6972. It is a useful equipment for Transformer / Switch Gear manufacturing units. Oil fettering agencies, repair shop and electrical maintenance departments.
-
product
Transformer Oil Gas Analysis
It is necessary to analyze outgas in transformer insulation oil in power plant facilities. Shimadzu offers a System GC compliant with ASTM D 3612 Method B (oil stripper sampling) or ASTM D 3612 Method C (headspace sampling). The Nexis GC-2030TOGAS3 system, equipped with a PDHID, enables the analysis of more trace amounts of permanent gas than conventional systems.
-
product
Oil Test Set
RR-OIL TEST SET also known as OIL BDV KIT is an equipment-designed and produced to test the ELECTRICAL STREGTH of Liquid Insulating Materials such as Transformer Oil, Capacitor Oil etc. The test set carries out test on these materials as per Indian Standard Specification IS 6792. This Oil Test Set is essential for Transformer & Switchgear Manufacturers, also for oil filtration units.
-
product
Automatic Oil Insulation Test Kit
The test kit is fully automatic and has the facility forAuto/Manual selections. The operator simply needs thesample in the test vessel & selects the required test. Testingcan be done as per many international ( IEC & Europeanstandards ) which are programmed into the instrumentmemory . Stand time, Stir times & Rate of rise of appliedvoltage can be selected in Custom Mode also , one setof such selected mode can also be stored in the memory. In addition to the above set can also perform withstand test(proof) tests. In this test the set allows the set voltage to pre-set value & hold for one minute to see if breakdown occurs. The backlit LCD is used for user friendly operationsduring the test process. It also display fault condition messages such as open ground and cover open . All the user selected programmes are chosen through(4x3) key pad.The test results can be printed along with with test type, date, time, breakdown test voltage, averages and deviations. Voltage value can be measured & printed with a resolution of 0.1kV. In reprint option it is possible to have number of printouts for the last test. For each test the readings are recorded and stored in memory.
-
product
Automatic Insulation Oil Dielectric(breakdown) Test
HDIIJ-80
HD Power Test Equipment Co.ltd
Automatic Insulation Oil Dielectric(breakdown) Tester is used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool, electric manufacturer and etc. It adopts full auto digital microcomputer, which has the function of high accuracy, strong anti-interference ability and safe reliability
-
product
Resistivity Meter
Resistivity meterRSM-500 is used for measuring the volume resistivity of transformer oil and other electrical insulating liquids. • Auto ranged from 109 to 1015 ohm cm • Test voltages: internally generated +500V DC
-
product
Dry Type Transformer Test
Wuhan Sangao Electrical Test Installations Limit Co.
GTB series dry testing transformer is adopted with new technology of winding epoxy vacuum pouring and CD type Iron core. Compared with similar product of oil immersed type transformer, it is light weight, smaller size, insulation strength and moisture-resistant is more improved.
-
product
Oil Withstand Voltage Tester
TE 6080
Wuhan Sangao Electrical Test Installations Limit Co.
TE6080 Automatic insulating Oil Tester, in accordance with IEC156, realizes the full automatic determination of insulating oil dielectric strength, make the original tedious and dangerous work become safe and easy. The instrument adopts special software and hardware anti-interference measures to eliminate the competing products prone to crash phenomenon. The new design will reduce the volume to the 1 / 2 of original, easy to carry and operate on-site.
-
product
Insulating Oil Testing
HAOMAI Electric Test Equipment Co., Ltd.
Tests that are concerned with the immediate condition and acceptability of insulating oil.
-
product
HV Test System up to 20000 Volt
Insulated test booth with large space for test items. 2 banana sockets for AC connection and 4 banana sockets for the DC connection of the DUTs. IC’s are tested in a long-term test. These are checked in an oil bath so that there are no air gaps to reduce the insulation. Maximum voltage 20 kV. Therefore, insulation tests must be carried out. Ensuring the standard-compliant test. For the safety of the operating personnel, the test cell is electrically locked while the high voltage measurement is active.
-
product
Three Cups Insulation Oil Dielectric Strength Tester
STY Series
Chongqing Assen Power Equipment Co., Ltd
STY series three cups insulation oil dielectric strength tester uses a microprocessor to automatically complete boost, keep stirring, static discharge, calculate, print and other operations, is a necessary measure in the conventional test equipment.
-
product
Oil Breakdown Voltage Tester
DTA IL
BAUR Prüf- und Messtechnik GmbH
Insulating oil testing with the BAUR DTA IL. The BAUR DTA Inline is a high performance and reliable oil tester for continuous testing of the breakdown strength of insulating oils during production (inline tests). The combination of extremely short switch-off times during breakdowns and the easy oil sample handling facilitate high quality statements and conclusions on the insulating oil quality.
-
product
Transformer Oil Dielectric Strength Testing
LS -JJ-II
Chongqing Lushun Scientific & Technological Development Co., Ltd.
1.The instrument has the function of automatic detection. 2.Tiny TPU-A panel printer is adopted for automatic printing out type insulating oil dielectric strength ATE is a full self-reacting device, which is developed according to the requirements in International IEC-156 and International GB507-86 "Insulating Oil Dielectric Strength Mensuration", combining the feedback opinions of all users .The instrument adopts singlechip as the leading part, and uses the method of "first setting and then testing". The whole process is controlled by automatic microcomputer. It is operated simply and used conveniently.
-
product
Oil Tan Delta Tester
OTD
The Oil Tan Delta (OTD) is a laboratory instrument, which measures the Tan Delta, Resistivity and Relative Permittivity of insulating liquids. These tests give a wider picture of the overall quality of the insulating oil, and will indicate if there is any contamination. Megger has developed features of the OTD to ensure that productivity levels within laboratories are maximised. The microprocessor controlled inductive heater means that there is uniformity of temperature throughout the cell, in compliance with IEC 60247, and for cooling a fan effectively speeds up the cell cooling time. The instrument has a temperature measuring range of 10 to 110 C, with an accuracy of 1 C. It can be set to preheat before testing takes place. The automated oil drain facility negates the need to move the oil vessel. User safety is paramount and with this in mind, Megger have designed independent and dual redundant high voltage cut-off circuitry. If for any reason the user needs to abort the test, this can be done so by pressing any key, immediately terminating the test and removing the high voltage. The design of the cell components maximise oil fill rate but minimise turbulence in oil flow and eliminate trapping of air. With only 32 cell components, it is easy to assemble and disassemble.
-
product
Insulation Oil Tester
KVJS-7000
KV Hipot Power Test Equipment Co.,Ltd
Insulation oil dielectric loss and resistivity tester is mainly used to test dielectric loss factor and resistivity of insulation oil and liquid insulation medium.
-
product
Oil Tangent Delta Tester
MG-I
Chongqing Kailian Yongrun Industrial Co.,Ltd.
It is designed to test dielectric loss factor(tangent delta tgδ) and capacitance of transformer oil, capacitor oil, cable oil and other insulation oils.
-
product
12 kV Insulation Fluid Test Cell
CP TC12
The CP TC12 oil test cell is for determining the relative permittivity, the dissipation factor and the power factor of insulating liquids such as transformer oil.
-
product
Insulation Oil BDV Tester
Wuhan Fanke Transformer Manufacture Co., LTD
Insulation Oil BDV Tester
-
product
OIP TYPE VOLTAGE TRANSFORMER
12kV - 145kV post type voltage transformers having Oil Impregnated Paper( OIP) as major insulation has been designed with several unique features.OIP insulated outdoor products are subjected to extreme climatic conditions and hence extra care is taken in the design and manufacturing of such transformers.
-
product
Oil Immersed Test Transformer
SG-YD
Wuhan Sangao Electrical Test Installations Limit Co.
AC and DC test oil immersed transformer.Traditional oil immersed test transformer is used to do power frequency withstand voltage and DC current withstand voltage test for variety kinds of high voltage electric device, insulating material.YD series oil transformer, also known as test booster, which test insulation strength under specified voltage for various electric products, components, insulation materials. It can test products insulation level, find insulation defect and judge overvoltage ability. It is widely used in power station, power supply and distribution system and research institute.
-
product
Electric Insulating Oil Tester
PortaTest
Portatesters are easy to use. Based on the test standard, you select the corresponding test sequence. Then, the required test probe and the electrode gap for the selected test standard is displayed. The setting gauge, included in the scope of delivery, facilitates the adjustment of the electrode gap. Afterwards you fill the insulating oil in the test vessel and close the test chamber.
-
product
GDGY Insulating Oil Tangent Delta Tester
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
It is applied to measure dielectric loss angle and Volume Resistivity of insulating oil etc.