Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
LXI High Frequency Matrices
Pickering's LXI high frequency (HF) matrix modules are suitable for switching frequencies up to 50MHz. They have an impedance of 50 and uses SMB signal connectors or with a larger case size is uses BNC connectors. This HF matrix is designed to provide a simple and scalable bidirectional matrix for radio frequencies and is intended for the easy construction of high performance bidirectional matrix switching systems.
-
product
Temperature & Process Calibrators
The most sophisticated industrial equipment will not be useful unless it is calibrated. GAOTek Process Calibrators are used to adjust instruments’ accuracy, and they are the only process calibrator you will ever need to carry. They can measure temperature, pressure, voltage, resistance and frequency, and can be used during troubleshooting. Through calibration, you can ensure that any equipment performs as expected and that it can be relied on to deliver predictable and accurate results that meet quality standards. GAOTek Process Calibrators come with a USB interface which makes it easier to transfer the results to other devices which otherwise would have taken a long time to transcribe them. Our Process Calibrators are for sale to the United States, Canada and globally.
-
product
Multifunction Process Calibrators
AMETEK Sensors, Test & Calibration
Our multifunction process calibrators read and source RTD, thermocouple, current, voltage, frequency, and resistance to calibrate or verify your process sensors. They can also be combined with APM CPF pressure modules to calibrate pressure, or a dry-block to calibrate temperature. The ASC-400 features a large full color display with an advanced simplicity, easy-to-use interface.
-
product
Frequency Reference
Quartzlock time and frequency standards offer a complete range of cost effective and low noise in both atomic controlled (rubidium oscillator) and GPS controlled (off-air) time and frequency reference, calibrators and standards. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
product
Electrical Calibrators
We offer different electrical calibrators for electrical quantities. We mainly offer products for DC signals related to process calibration, such as current, voltage, resistance and frequency.
-
product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX02
The N5295AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
110 GHz Frequency Extender
N5293AX53
The N5293AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
Your product description goes here.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
product
110 GHz Frequency Extender
N5293AX03
The N5293AX03 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Calibrators
A calibrator or process calibrator is used for basic measuring, testing and regulation techniques for setting and verifying test installations and instrumentation. PCE Instruments' calibrator products are lightweight yet made of durable materials. Our calibrator devices are easy to use and primarily handheld, though fixed installations are possible. A calibrator is valued by technicians due to its high level of accuracy and its universal range of applications.
-
product
Calibrators
Portable and user friendly calibrator, ideal for checking sound level meters and dosimeters on the measurement site, or in the laboratory.
-
product
Calibrators
Is a device used to adjust an instrument accuracy, often associated with a specific application.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Multifunction Calibrators
These field and bench calibrators source, simulate, and measure pressure, temperature, and electrical signals with exceptional precision. They can automate calibration procedures, store data, and even calibrate and troubleshoot HART-compatible devices. Our bench calibrator can even be used to calibrate our field calibrators. Also find here 5.5- and 6.5-digit bench multimeters for to assist with a variety of general test and calibration applications.
-
product
Blackbody Calibrators
Omega offers a diverse portfolio of blackbody calibrators used to calibrate infrared pyrometers. Blackbody calibrators use a high emissivity target plate or target cavity to minimize error.
-
product
Process Calibrators
Handheld, battery-powered instruments used for field testing and calibration of industrial process equipment.
-
product
Primary Calibrators
Why is the adjustment and primary calibration of air sampling instruments necessary? Instruments that sample air must be flow adjusted, calibrated and routinely checked to ensure the accuracy of flow rate. The frequency of flow adjustment and/or calibration depends on the use, care and handling of the air sampling instruments and the regulations they are complying with. Determining exposure to various physical, chemical, radiological and biological substances is based on the accuracy of the total volume of air sampled and the sample duration.