Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe Wide Current Range Matrix Module, 6x4, 2-Pole, X & Y Loop-thru
40-514-002
The 40-514-002 (PXI) and 42-514-002 (PXIe) are low density matrices in 6x4 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
NI-9219, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module
785994-01
100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The NI‑9219 is designed for multipurpose testing. With the NI‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel.
-
product
Single Phase Transformer Ratio Meter
*Ideal for VT testing*Bushing Current Transformers (BCTs)*Higher resolution*Excitation current meter
-
product
Magneto-inductive Testing
MAGNATEST D-HZP
Foerster Instruments, Incorporated
The MAGNATEST D-HZP by FOERSTER is the ultimate magneto-inductive test instrument: the fully automatic system tests materials for their properties. It operates in single coil absolute mode, making a comparator coil unnecessary. The combination of high excitation currents and complex evaluation electronic equipment detects even very small structural discrepancies. The MAGNATEST D-HZP also provides comprehensive options for documenting test results, such as test piece statistics, histogram, and test data export, which are displayed clearly on the large color display.
-
product
Current Transformer Analyzer
CT Analyzer
Current transformer testing in a multifunctional instrument performing excitation, ratio, polarity and winding resistance tests on current transformers as well as burden impedance measurement.
-
product
PCB GPTA02, 10 mV/g, IEPE, 1 Hz to 5 kHz, Accelerometer, Triaxial Vibration Sensor
784169-01
The PCB GPTA02 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB GPTA02 features a sensitivity range of 10 mV/g and requires a 4-socket plug-to-3 BNC plug cable.
-
product
Turns Ratio Testers
TRT Standard Series
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
product
Intelligent A/D I/O Unit
RAD242
Model RAD242 is an intelligent, two-differential-channel, 24-bit analog-input interface unit that includes a Delta-Sigma A/D converter. The converter has a digital output filter with adjustable notch frequency from 10 Hz to 2000 Hz. The pod also has 13 bits of digital input/output. A precision 10 VDC voltage that can be used for transducer excitation is available at connector pin 5. As much as 60 mA current can be provided. It is packaged in a NEMA 4 enclosure for remote installation in harsh environments. RAD242 also provides a user-definable interrupt input and counter/timer input. An optional RAD Firmware Development Kit is available if you wish to use those user-programmable input lines or to develop a custom program.
-
product
NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
779592-01
4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Current Transformer Tester
CT-T1
The CT-T1 is a microprocessor-based Current Transformer Tester that measures CT excitation current, turns ratio, and winding polarity tests, all without having to switch the leads during testing. The instrument has a fully automatic knee point detection (ASA 10/50, IEEE 30°, IEEE 45°). Although includes 5 low side taps and 1 high side tap.
-
product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
780989-01
The PCB HSTC33 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTC33 features a sensitivity range of 100 mV/g and requires a low-noise coaxial cable.
-
product
Load Cell Amplifier Signal Conditioner with DB9 Connectors
MODEL LCA-9PC
The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
product
Photoelectric Direct Reading Spectrometer
TY-9610
Wuxi Tianmu Instrument Technology Co., Ltd.
1, Optical SystemStructure: Pa type - RungeRaster: Radius of curvature: 750mmIncident slit width: 20 μ mExit slit: high-precision photolithography of the entire slit, according to different elements set up 30u-75u slit width.Detector: Photomultiplier tube ( PMT ) detector2, all digital excitation light source1. Fully digital intelligent composite light source DDD technology, which can automatically adjust the excitation parameters of light source according to the excitation characteristics of different materials, and truly realize full digital control. 2. Using the all-digital control mode, high-energy pre-combustion technology ( HEPS ), ultra-stable energy release stimulates the sample in an argon atmosphere. 3. The application of all-digital light source improves the measurement accuracy and similarity of the sample, improves the sample excitation speed, improves the spark stability, and makes the sample have better reproducibility. The maximum discharge current reaches 400A .
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
product
Current Transformer Tester
HTCT-300
Full-featured, can not only satisfy various CT (eg: protection, measurement and TP category) but also PT type electromagnetic unit for its excitation characteristics (ie voltage current characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio deviation, angle deviation and other test requirements.
-
product
Transformer Turns Ratio Meter XTRM-3
XTRM-3
The Motwane Manufacturing Company
Your product description goes here. Motwane’s transformer turn ratio meter XTRM-3 is a new generation fully automated kit to measure turns ratio, voltage ratio, ratio error, phase displacement & excitation current in a transformer. It automatically detects the transformer vector group. Its user-selectable test voltage feature provides for testing various ratings of power transformers.
-
product
NI-9219, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module
779781-02
100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The NI‑9219 is designed for multipurpose testing. With the NI‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel.
-
product
PCB IMIC01, 100 mV/g, 2-Pin, Accelerometer, Industrial Vibration Sensor
780985-01
The PCB IMIC01 is an industrial Vibration Sensor designed for permanent installations. This sensor helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. The PCB IMIC01 features a sensitivity range of 100 mV/g and uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The sensor supports the IMI Industrial Accelerometer Cable as well as the MIL2M-Breakout Cable.
-
product
Temperature Monitor
SIM922A
Stanford Research Systems, Inc.
The SIM922A has a programmable, precision 10 µA current source to provide sensor excitation. Results can be displayed in either kelvins or volts.
-
product
Transformer Ratio Meters
TRM-200
Three phase lead switching network • Excitation current meter Accessories: Range Extender 1:5.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-01
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
785189-01
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Load Cell Amplifier Signal Conditioner with Removeable Terminals
MODEL LCA-RTC
The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
product
sbRIO-9218, Non-Enclosed, 24-Bit, 51.2 kS/s/channel, 2-Channel C Series Universal Analog Input Module
783362-02
Non-Enclosed, 24-Bit, 51.2 kS/s/channel, 2-Channel C Series Universal Analog Input Module - The sbRIO‑9218 helps you perform multipurpose testing. With the sbRIO‑9218, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors. You also can use the sbRIO‑9218 to perform quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. You can individually select and perform a different measurement type on each channel. Additionally, the sbRIO‑9218 features 60 VDC analog input isolation. Non-enclosed modules are designed for OEM applications.
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-01
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
CT PT Tester
HTCT-300 / 357
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement of current voltage transformer excitation characteristics, excitation parameters, turns ratio, polarity coil resistance, etc.
-
product
Pt RTD Temperature Monitor
SIM923
Stanford Research Systems, Inc.
The four channels in the SIM923 have independent, stable 1 mA current sources to provide sensor excitation. Sensor resistance is determined ratiometrically with a half-bridge circuit consisting of the sensor and an internal reference resistor.
-
product
Microphone Preamplifier
HT426E01
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA
-
product
sbRIO-9219, Non-Enclosed, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module
781027-01
Non-Enclosed, 100 S/s/channel, 4-Channel C Series Universal Analog Input Module - The sbRIO‑9219 is designed for multipurpose testing. With the sbRIO‑9219, you can measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors, as well as make quarter-bridge, half-bridge, and full-bridge current measurements, with built-in voltage and current excitation. Each channel is individually selectable, so you can perform a different measurement type on each channel. Non-enclosed modules are designed for OEM applications.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-02
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.