Filter Results By:
Products
Applications
Manufacturers
- TEAM SOLUTIONS, INC.
product
16 SE Or 8 Diff. Input Channels, 4 Analog Current Output Channels, PCI Express
APCIE-3121-16-4C
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
product
PXI Analog Output/Current Loop Simulator Module - 16 Channel
41-765-001
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Precision Current Loop Calibrator With Hart Communications
LC-110H
The Martel LC-110 and LC-110H are mA (loop) calibrators designed to take the loop calibrator class to the next level. The new LC-110 series feature a user friendly interface with dedicated buttons and a rotary encoder (Quick-Set Knob). This combination drastically reduces the time it takes to measure, simulate, or source both voltage and current and power up a loop. The rugged ABS plastic case is contoured to easily fit a technician's hand and the large back lit graphics LCD is best in class. The LC-110H differs from the standard LC-110 in that it incorporates HART communications and supports a select set of the HART universal and common practice commands. This unique feature allows the LC-110H to be used as both a loop calibrator and communication tool.
-
product
Fuse Buddy Current Loop
307M/308B
*Just clamp your current probe over the loop to access the amperage draw through a fused circuit. *Easy testing access, plugs right into fuse socket, no more hand made adapters. *Testing range 0-30 Amps - Do Not Exceed 30 Amps
-
product
Split Core Hall Effect DC Current Sensor
CYHCT-C2TC
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a split core and a high galvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
product
Digital LOOP/PSC/LOAD Tester
1825 LP
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures the voltage drop as if 16A was flowing between Line and Neutral.● Displays voltage without current (V at 0A).● Display voltage as if 16A flowing between Line and Neutral (V at 16A).● Loop test for L-E● PSC between L-N.● Single one smart push button operation; ON, Scroll through results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software range).● Combined prospective short circuit current, loop and load tester.● Display can be customized for large orders.
-
product
Bench Digital Multimeter, 40000 Count, True RMS, Auto, Manual Range, 1 kV, 10 A, 4.75 Digit
72-1020
This unit measures AC/DC voltage and current, resistance, capacitance, frequency, and temperature. It also provides diode and audible continuity test, as well as 4~20mA loop testing.
-
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
product
Loop-Powered Digital Panel Meter
88-PRO
The 88-PRO Process Meter may be connected directly to a 4-20 mA, 10-50 mA or 1-5 mA current loop, with no need for additional power to the meter. This is because the meter is powered directly by the current loop, developing a maximum voltage drop of 2.5 V.
-
product
Multifunction Electrical Installations Meter
MPI-520
The MPI-520 multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520 is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.Wide range of standard accessories enable to perform all necessary measurements and safety test. Highly professional portable multifunction meter with memory of measured parameters.
-
product
Current Loop Adapter
OP-1C
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
PXI Analog Output/Current Loop Simulator Module - 4 Channel
41-765-004
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Dual High Speed Power Supply
VX4620
Dual high speed power supplyLow noise linear output stage with 200 Vpp and 1 AProgrammable bipolar voltage and positive/negative current limitsStable control loop even on long load linesAuto sensing featureProgrammable slew rateProgrammable over GPIB, USB or RS232Fast rise and fall times due to integrated sink capability
-
product
Loop Resistance Measuring Device According to DIN EN 61557-3 (VDE 0413-3)
PeakTech Prüf- und Messtechnik GmbH
A loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
product
Remote Indicators
ABB field indicators provide a convenient way to access the field instruments data when they are located in remote or difficult to access areas. Powered directly from the 4-20 mA current loop, they require minimal effort to setup.
-
product
Multifunction Electrical Installations Meter
MPI-520S
The MPI-520S multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520S is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.
-
product
Lightning Current Generator
Shanghai Guantu Technology Co., Ltd.
The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.
-
product
Industrial 4-20mA DAC Solution
Analog Devices portfolio of leading industrial digital-to-analog converters address the challenges of enhancing system accuracy, reliability, and overall functionality while reducing form factor and power dissipation. The products provide a range of programmable output ranges from standard 4–20 mA for current loop communication to ±10 V for actuator control. They simplify industrial system design by offering considerable control functionality and advanced on-chip diagnostics to maximize system up time. ADI industrial converters also eliminate the need for costly calibration routines needed by some traditional discrete architectures.
-
product
Multifunction Meter for Electrical Installations
AMPI-530
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
product
Closed Loop Hall Effect Current Sensors/Transducerswith Rectangle Windows
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used formeasurement of DC and AC current, pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
product
PXI Analog Output / Current Loop Simulators
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
product
Insolator
The USB isolators effect a potential decoupling of all USB connections and separate the 'normal' PC system from the critical application. They are the professional tools to avoid and fight ground loops and equalizing currents and to protect against overvoltage.
-
product
NI-9265, 4-Channel C Series Current Output Module
779334-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
Multifunction Electrical Installations Meter
MPI-525
Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.
-
product
Current Loop Expansion Kit
OP-SB85C
This expansion kit supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
Open Loop Current Sensor
C03 30A
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
product
Mezzanine System
5658
ECM P/N 5658 provides eight channels of 16 bit current measurement in the 0 to 25 milli-amp range. Each channel allows independent common mode voltages from -100 volts to +100 volts. Current detection is accomplished with a precision 100 ohm current sense resistor, creating a voltage drop of 2V in the current loop at 20 milli-amps.
-
product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
product
NI-9265, 4-Channel C Series Current Output Module
783733-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
PCI Express 8 Reed Relay Output
8012e
The 8012e Low Profile PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.
-
product
NI-9266 , 8-Channel C Series Current Output Module
785046-01
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.