Filter Results By:
Products
Applications
Manufacturers
CT Test
measures insulation, excitation current, turns ratio, winding polarity saturation and/or winding resistance. Current Transformers
- Pickering Interfaces Inc.
product
EBIRST 50-pin D-type Test Tool
93-005-001
eBIRST is a range of USB controlled test tools capable of performing automated path resistance tests on Pickering Interfaces PXI, LXI or PCI controlled switching solutions. Each tool simply interfaces with the switching system's connector so a test can be run using the supplied Windows-based software.
-
product
Relaying Current Transformer Analyser
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
product
Current Transformer Testers
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
product
Energy Meter Test Bench
SP-6103
Shanghai Powoo Industry Develop Group Limited
- Single phase energy meter test bench - auto-calibration system - accuracy class: 0.1/0.2 class - Standard CT; 0.01/0.02 - output voltage: 0-220V9240V option); range: 0-120% - fine adjustment: 0.01% - output current: 0-100A; (option for 200A)- fine adjustment: 0.0001A (min)
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
Current Transformer Tester
HTCT-300
Full-featured, can not only satisfy various CT (eg: protection, measurement and TP category) but also PT type electromagnetic unit for its excitation characteristics (ie voltage current characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio deviation, angle deviation and other test requirements.
-
product
CamTrac Z-Axis Test Fixture Kits
CT Serie
The CT Series Mechanical Kits, utilizing the patented CAM mechanism1, offset the same precision linear motion. The 'Z' axis motion is ideal for a larger point count mechanical test applications.The CT Series features a hinged 3/8" FR4 probe board, tooling holes for precision alignment, removable sides, precision shafts and cam slide block assemblies, and a pan latch assembly.
-
product
Primary Injection Testing
For primary injection testings, PONOVO has been providing users, various testing equipment, including CT/PT test set, Single phase universal test test upto 250A and 1000A, etc. CT/PT tester could be used for testing all kinds of CT testing, with additional PT testing functions.
-
product
Current Transformer Tester
CT-T1
The CT-T1 is a microprocessor-based Current Transformer Tester that measures CT excitation current, turns ratio, and winding polarity tests, all without having to switch the leads during testing. The instrument has a fully automatic knee point detection (ASA 10/50, IEEE 30°, IEEE 45°). Although includes 5 low side taps and 1 high side tap.
-
product
Complete Field Meter Site Testing Solution
7 Series
We raised the industry standard by introducing the PowerMaster 7 Series as a true 3-phase analyzing reference standard with internal 3-phase current and voltage source capability. The innovative design of the PowerMaster® 7 Series allows utilities to fully test a metering installation with one piece of equipment. Customer load meter testing, phantom load meter testing, CT burden and ratio testing, CT de-magnetization, PT ratio testing, and transducer testing can all be performed with one solution. In addition, vector diagrams, voltage and current waveforms, and harmonics data up to the 100th harmonic can all be analyzed to complete a true wiring verification.
-
product
Instrument Transformer Calibrators
CTPT 81
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
product
Hand-held 3-Phase Meter Tester
3 Series
Powermetrix continues its industry leadership with the introduction of Powermetrix Remote Manager (PRM) for the PowerMaster® 3 Series. Powermetrix Remote Manager enables wireless control of essential and various metering site accuracy tests contained within PowerMaster® 3 Series from any Windows compliant system up to 100 feet in any environment, including high EMF environments! Customer load Meter Testing, CT/PT ratio testing, CT/PT burden measurement, meter register/demand testing, and wiring verification are all easily performed with this extremely portable, hand-held 3-phase power analyzer. In addition, with the new Model 335, phantom load meter testing and CT burden added testing are available to complete your field-testing needs.
-
product
CT/PT Calibrator
HEY-H / 605
Wuhan Huatian Electric Power Automation Co., Ltd.
Intelligent instrument calibrator for PT CT error and impedance admittance test.
-
product
Substation Tester
JYH
JYH C CT PT Analyzer,full-featured, can not only satisfy the test requirements of various CTs (include TP class), such as the excitation characteristics (i.e., volt-ampere characteristics), ratio, polarity, secondary winding resistance, secondary burden, ratio error and phase displacement, but can also be used for the tests of various PTs, including excitation characteristics of the electromagnetic unit, ratio, polarity, secondary winding resistance, ratio error and phase displacement.
-
product
Transformer Demagnetization Tester
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
product
Automatic Instrument Transformer Test Set
*ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus
-
product
CT & PT Test Kit
PCT200i
PCT200i is specially designed for current transformer characteristic test.This CT analyzer can finish the measurement class CT and TYP class CT.The additional functions include ratio and angle differential tests (the measurement points in the GB standard),FS and inductance,steady-state parameters,peak error and transient parameters,etc.
-
product
Secondary Current Injection Test Trolley
SCR ELEKTRONIKS have developed SECONDARY CURRENT INJECTION TEST TROLLEY for Switchgear items, CT manufacturer and where three phase current application is called for. It is low Voltage, 3 phase Current source with control circuitry, digital read out for test current and trip time measurement. We can select different CT ranges for each phase independently and adjust the current as per the required test Current.
-
product
Cable Transmission Tester
SIGNALTEK CT
If you install or maintain data cabling, SignalTEK CT allows you to generate PDF test reports that prove installed links run at Gigabit Ethernet transmission rates.
-
product
Semi-Rigid Replacement Flexible Cables
StormFlex® 034, 047, 086, & 141
Ruggedness and durability combined with ultra-small 0.038" diameter, very low weight, and extreme flexibility make Storm Flex® 034 cable assemblies the perfect fit for applications including gimbal, digital test and high density.With 0.055" and 0.096" diameters, durable construction, and low profiles in SMA SP configuration, Storm Flex® miniature cables offer superior electrical performance in a trouble-free, compact assembly.Combining flexibility and durability with a larger 0.160" diameter, Storm Flex® 141 maintains excellent electrical characteristics through multiple flexures.
-
product
Current Booster
BUX
The current boosters allow performing tests up to 2000A, 3000A and 5000A. The option is made of a module, which incorporates a power transformer, which generates a low-voltage, high current output and a metering CT, which measures the output current and sends the metering to eKAM.
-
product
Transformer Testing Equipment
Offering you a complete choice of products which include Automatic Transformer Turns Ratio Instruments (ATRI- 3), Automatic Transformer Turns Ratio Instrument (ATRI-201), VTRI-2000 ( Transformer turns ratio instrument ), Current Transformer Test Set (CTC-1), Potential Transformer Tester ( PT Tester ) and Current Transformer Tester ( CT Tester ).
-
product
Turns Ratio Testing
The transformer turns ratio test, or TTR test, confirms that the transformer has the correct ratio of primary turns to secondary turns. Using this test correctly can help to identify tap changer performance, shorted turns, open windings, incorrect winding connections and other faults inside transformers. Megger’s range of TTR testers are robust to withstand the harsh conditions that some transformer testing in. The range includes varying features to simplify and speed up testing as well as 3 phase TTR testers and PT and CT TTR testers.
-
product
Polarity Checker
PW-VP50
PW-VP50 CT Polarity checker is the favorable meter which can be used for field CT and transformer polarity test in power plants, substations and any other application which may need to check the polarity. There are 2 units included in PW-VP50. One master machine which can automatically inject...
-
product
Test Switches
Series FT
An industry standard for CT & VT isolationfor instrument transformer and connected device testing.Up to 10 poles; Numerous configurations availableTypically mounted on switchgear and relay panels10 pole test plug available; UL and cUL recognized.
-
product
GAOTek Three-Channel Leakage Current Tester
GT00YB00ZV
The GAOTek Three-Channel Leakage Current Tester provides online measurement, monitoring, and recording of three channel AC leakage currents simultaneously by adopting the latest CT and magnetic shielding technology. This instrument provides highly accurate and reliable measurements. Additionally, it can locate insulation faults and repair electrical lines. It is composed of a special alloy and consists of a test monitoring software, current clamp, and communication cable. The instrument can store 3900 sets of data and enables online and real time monitoring, historical data inquiry, read, inquire storage, generation, and printing of a fitting curve. It is widely used in 380/220 power systems. It complies with IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ (600 V), and IEC61326 (EMC standard) safety codes.
-
product
Digital Arrester Clamp Tester
ALCL-40
MULTI MEASURING INSTRUMENTS Co., Ltd.
*ALCL-40 is designed to test the diagnostic of OXIDE SURGE ARRESTER.*The least influence from the external magnetic field and noise by triple shielding of CT.*Compliant with IEC6099-5.*Enabled the measurements for 100nA resolution and harmonics current.
-
product
CT Admittance Tester
505B
Red Phase Instruments Australia Pty Ltd.
Field testing kWh meters is easy, field testing CTs when live is much more difficult. Our admittance tester can test CTs live with 50Hz or 60Hz current in the metering circuit. This technique does not confirm the accuracy of a CT but it will detect faults that give metering errors, such as shorted turns, metering circuits shorted to ground and tampering of CTs. CT faults can cause large revenue losses. Admittance testing only adds 10 minutes to a routine polyphase meter test, giving cheap insurance.
-
product
Primary Current Injection Test Set
T 2000
T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.
-
product
Test Automation Platform
Askida CT
Askida CT changes the way automated tests are carried out. It is the only platform on the market that lets you do true end-to-end testing automation without requiring deep technical skills. You can easily define your testing strategy and convert your manual tests into automated ones in one simple click.
-
product
Current Transformer Test Set
Vanguard Instruments Company, Inc.
The EZCT-2000C is Vanguard’s third-generation microprocessor-based current transformer test set. Designed specifically for CT testing, the EZCT-2000C has the following outstanding features that can greatly increase productivity and save time during the commissioning stage: