Filter Results By:
Products
Applications
Manufacturers
IEPE Microphones
measure acoustic frequency, time and noise levels.
-
product
PCI-4462, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 4-Input Sound and Vibration Device
779309-01
The PCI‑4462 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous four-channel dynamic signal acquisition with six programmable gain settings for making high-accuracy, frequency-domain measurements. The PCI‑4462 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications for dynamic signal acquisition devices include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.
-
product
NI-9231 and cDAQ-9171 USB Sound and Vibration Measurement Bundle
865665-01
NI-9231 and cDAQ-9171 USB Sound and Vibration Measurement Bundle - The USB Sound and Vibration Measurement Bundle with NI-9231 and cDAQ-9171 includes the NI-9231 C Series Sound and Vibration Input Module and the cDAQ-9171 CompactDAQ Chassis for sound and vibrations measurements. This bundle provides a portable, USB-based sensor measurement system that helps you measure signals from integrated electronic piezoelectric (IEPE) and non IEPE sensors such as accelerometers, tachometers, and proximity probes. The included NI-9234 features 8 channels with built-in anti-aliasing filters that automatically adjust to your sample rate. Additionally, the bundle supports simultaneous sampling and high dynamic range measurements necessary for modern measurement microphones and accelerometers.
-
product
USB-4432, 102.4 kS/s, 100 dB, 0.8 Hz AC/DC Coupled, 5-Input Sound and Vibration Device
780421-01
The USB-4432 is designed for sound and vibration measurements. Four of the input channels incorporate integrated electronic piezoelectric (IEPE) signal conditioning for accelerometers and microphones and built-in antialiasing filters that automatically adjust to your sampling rate. The fifth input channel does not include IEPE support.
-
product
PCI-4461, 204.8 kS/s, 118 dB, 3.4 Hz AC/DC Coupled, 2-Input/2-Output Sound and Vibration Device
779307-01
The PCI‑4461 is a high-accuracy data acquisition module specifically designed for sound and vibration applications. It provides simultaneous two-channel dynamic signal generation and simultaneous two-channel dynamic signal acquisition with six gain settings to configure the input range. The PCI‑4461 also includes software-configurable AC/DC coupling and integrated electronic piezoelectric (IEPE) conditioning to ensure precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive test; noise, vibration, and harshness (NVH) analysis; and machine condition monitoring.
-
product
NI-9231, 8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module
783610-01
8-Channel, 51.2 kS/s/channel, -5 V to 5 V, C Series Sound and Vibration Input Module - The NI-9231 is a high-density sound and vibration module that can measure signals from integrated electronic piezoelectric (IEPE) and non-IEPE sensors such as accelerometers, tachometers, and proximity probes. It can perform the high dynamic range measurements necessary for modern measurement microphones and accelerometers and features simultaneous sampling. The NI-9231 incorporates both a TEDS input path and 2 mA of IEPE signal excitation source that can be turned on and off, removing the need for external sensor power and reducing the complexity of the data acquisition system.
-
product
PXI-4461, 204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module
779687-01
204.8 kS/s, 2-Input/2-Output PXI Sound and Vibration Module—The PXI‑4461 is designed for sound and vibration applications. It provides two-channel dynamic signal generation and two-channel acquisition, and you can use one of six gain settings to configure your input range. The PXI‑4461 also includes software-configurable AC/DC coupling and IEPE conditioning. The PXI‑4461 includes the hardware and software needed to make precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. Common applications include audio test; automotive noise, vibration, and harshness (NVH); and machine condition monitoring.
-
product
Amplifier
AC-100
The voltage amplifier for connecting piezoelectric acceleration meters, microphones, and other primary voltage output transducers to FFT spectrum analyzers with the IEPE standard current output (ZET 017-U2, ZET 017-U8, A19-U2).
-
product
PXIe-4499, 204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module
781370-01
204.8 kS/s, 114 dB, 4 Gains, AC/DC-Coupled, 16-Input PXI Sound and Vibration Module - The PXIe‑4499 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4499 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4499 delivers simultaneous sample on all channels. In addition, the PXIe‑4499 includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
product
PXIe-4492, 204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module
781490-01
204.8 kS/s, 113 dB, 2 Gains, 0.5 Hz AC/DC-Coupled, 8-Input PXI Sound and Vibration Module - The PXIe‑4492 is designed for sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the module is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4492 delivers simultaneous sample on all channels. In addition, it includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gains, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
product
4-CH 24-Bit 128kS/s Dynamic Signal Acquisition USB 2.0 Module
USB-2405
The USB-2405 is a 24-bit high-performance dynamic signal acquisition USB module equipped with 4 analog input channels providing simultaneous-sampling at up to 128 kS/s per channel. The USB-2405 also features software selectable AC or DC coupling input configuration and built-in high precision 2 mA excitation current to measure integrated electronic piezoelectric (IEPE) sensors such as accelerometers and microphones.
-
product
USB-4431, 102.4 kS/s, 100 dB, 0.8 Hz AC/DC Coupled, 4-Input/1-Output Sound and Vibration Device
780164-01
The USB-4431 is designed for sound and vibration measurements. Input channels incorporate integrated electronic piezoelectric (IEPE) signal conditioning for accelerometers and microphones. The four USB-4431 input channels simultaneously digitize input signals. The analog output (AO) channel is ideal for stimulus-response tests and can be synchronized to the AI channels.
-
product
Signal Conditioners
Metra Mess- und Frequenztechnik in Radebeul e.K.
Metra has been manufacturing amplifiers for piezoelectric transducers for over 50 years. We offer economic charge amplifiers and signal conditioners for IEPE transducers including microphones.
-
product
PXIe-4497, 204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module
781369-01
204.8 kS/s, 114 dB, 2 Gains, AC/DC-Coupled, 16-Analog Input PXI Sound and Vibration Module - The PXIe‑4497 is designed for high‑channel‑count sound and vibration applications. With 24-bit analog inputs and IEPE constant current signal conditioning, the PXIe‑4497 is ideal for making precision measurements with microphones, accelerometers, and other transducers that have very large dynamic ranges. The PXIe‑4497 delivers simultaneous sample on all channels. In addition, the module includes built-in antialiasing filters that automatically adjust to your sample rate, software-selectable input gain, and TEDS smart sensor support for error-free setup. Common applications include noise, vibration, and harshness (NVH) analysis; large microphone arrays; and dynamic structural test.
-
product
NI-9250, 2-Channel, 102.4 kS/s/ch Simultaneous, ±5 V, C Series Sound and Vibration Input Module
783827-01
2-Channel, 102.4 kS/s/ch Simultaneous, ±5 V, C Series Sound and Vibration Input Module - The NI‑9250 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers and microphones. The NI‑9250 is also compatible with smart TEDS sensors. The NI‑9250 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
PXI Sound and Vibration Module
PXI Sound and Vibration Modules are designed specifically for applications like audio test and measurement, noise and vibration diagnostics, machine condition monitoring, automotive test, noise, vibration, and harshness(NVH) analysis, and laboratory research. They provide software-configurable AC/DC coupling, antialiasing filters, and IEPE conditioning to ensure precision measurements with microphones, accelerometers, and other transducers with large dynamic ranges.
-
product
IEPE Impact Hammers
Our range of general purpose IEPE impact hammers offer a range of great cost effective solutions for a majority of applications requiring the excitation of a structure. The most common application being Modal testing whereby the structure is excited using the impact hammer and the response of the structure is measured using accelerometers. However instrumented hammers can also be used for crack detection and other structure related investigations.
-
product
Microphone Preamps
Applied Research and Technolgy
Unlock your mic's full potential with advanced features like variable impedance, mid-side processing, and real tube warmth.
-
product
Microphone Interfaces
MEMS
Listen offers 2 MEMS digital microphone measurement interfaces from Portland Tool & Die, the laboratory-grade DCC-1448 and the low cost PQC-3048 for production line use.
-
product
Microphone Preamplifier
426A11
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
product
Microphone Preamplifier
426B03
Performance: Nominal Microphone Diameter:1/4"Frequency Response: (0.1 dB) (re 1 kHz)5 to 126000 Hz5 to 126000 Hz Frequency Response
-
product
Microphone Arrays
One of the most important parts of an Acoustic Camera is the microphone array. It determines the spatial distribution of the acoustic microphones and therefore measurement performance of the whole system. In order to achieve the maximum possible performance in any given application, we offer a wide variety of microphone arrays. No matter if the measurement is beamforming, intensity or holography ... we have the right microphone array. For special applications we can design and build custom made microphone arrays according to the requirements of the application.
-
product
Measurement Microphones
All microphones are omni-directional and 48V phantom powered. The XL2 Analyzer microphones include an electronic data sheet. The Automated Sensor Detection (ASD) of the XL2 automatically reads this data sheet, and recognizes the microphone model, sensitivity and calibration data. This ensures accurate measurement results.
-
product
Measurement Microphone
UMM-6 USB
Precision condenser microphone for critical measurement and recording applicationsConnects to your PC or Mac via USB portTrue omnidirectional pattern with calibrated flat frequency responseRugged construction with high-quality componentsCompact design; includes sturdy carrying case with foam insertCompatible with most industry-standard measurement software
-
product
Low Noise Prepolarized Microphone
378A04
The 378A04 is a matched system that is comprised of a high sensitivity microphone and a low noise preamplifier that contains a built-in filter that enables the free-field response to remain flat over a wide frequency range. The system requires a minimum of 4 mA and measures to 6.5 dBA (5.5 dBA typical) within a cost efficient, prepolarized (0V) design. PCB's model 378A04, the industry's first prepolarized low noise microphone and preamplifier system allows you to measure extremely low amplitudes. In the past this was only possible with externally polarized solutions. With a typical noise floor of 5.5dBA, this microphone system delivers all of the benefits commonly associated with prepolarized systems.
-
product
ICP Microphone System
378C10
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
product
Microphone Preamplifier
426A30
1/2-inch preamplifier with 7-pin LEMO connector (for externally polarized microphones)
-
product
Microphone Preamplifier
426B31
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
product
Microphones
MIC-01, MIC-02 and MIC-03 are low cost precision condenser electret microphones perfectly suited for laboratory and on-field acoustical measurements. They have identical performances but differ for their physical size; MIC-01 is preferable for fixed laboratory installations while MIC-02 is highly manageable due to its short length; MIC-03 is the best where space saving is a must. Their frequency response is individually tested against specifications and the sensitivity value is supplied. MIC-01 & MIC-02 & MIC-03 can be directly connected to your CLIO system's input.
-
product
IEPE Triaxial High Sensitivity Accelerometer 10V/g
HDBV-1000
HDBV-1000 is a tri-axial accelerometer for the measurement of human exposure to whole-body vibrations, according to ISO 2631 and ISO 8041.