Filter Results By:
Products
Applications
Manufacturers
- Applied Instruments, Inc.
product
Forward Path NPRT 2200 Noise Power Ratio Test Set
NPRT 2200-F
The NPRT 2200 measures the NPR of a device across a range of power levels. This test quantifies intermodulation distortion and determines the dynamic range of optical transmitters, amplifiers and other active HFC network devices. The included PC software uses predefined test setups to run a "Power Sweep" series of NPR measurements and graph the results.
-
product
Relaying Current Transformer Analyser
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
product
Transformer Turns Ratio Testers
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
product
Turns Ratio Meter 1 Phase
TR-1 / TR-1P
Raytech Single Phase Transformer Turns Ratio Meter TR-1/P was designed to be a rugged and reliable automatic transformer Ratiometer. This system has a high degree of accuracy and will test ratios to 4000:1. The design of this test system is based upon the popular Raytech Automatic Three Phase test set: TR-Mark III.
-
product
Primary Current Injection Testers
Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.
-
product
ATTR Auto Transformer Turns Ratio Tester
Chongqing Assen Power Equipment Co., Ltd
Transformer turns ratio tester is a new type of fully automatic tester that uses modern electronic technology to measure the ratio of single-phase and three-phase transformers, and does not require any manual “zero” balance.
-
product
CT PT Tester
HTCT-300 / 357
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement of current voltage transformer excitation characteristics, excitation parameters, turns ratio, polarity coil resistance, etc.
-
product
Acoustic Imager
Can be used for quick on-site testing of current transformers in metering installations. They are designed and manufactured to test transformers’ primary current, secondary current, and turns ratio and identifies phase type and polarity.
-
product
Standard CT
6300A
The Model 2509 Instrument Current Transformer is a 6300 A ampere CT designed for precision measurement of AC current or for Instrument Current Transformer calibration applications. The CT can be installed on a bus bar or it can be used with a primary conductor consisting of number of turns. The 6300 CT is designed with a tapped primary & a tapped secondary winding, thus providing a large number of ratios over a range of 5 to 6300 amperes.
-
product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
product
HV Test Set
Beijing GFUVE Electronics Co.,Ltd.
Used for testing transformer, circuit breaker & switch etc by engineer, for example TTR tester can test transformer turns ratio.
-
product
*Beam Propagation Analysis
M²
M², or Beam Propagation Ratio, is a value that indicates how close a laser is to being a single mode TEM00 beam, which in turn determines how small a beam waist can be focused. For the perfect Gaussian TEM00 condition the M² equals 1. M² cannot be determined from a single beam profile measurement. The ISO/DIS 11146 requires that M² be calculated from a series of measurements. M² is measured on real beams by focusing the beam with a fixed position lens of known focal length, and then measuring the characteristics of the artificially created beam waist and divergence. We have a number of solutions for the measurement of M² ranging from simple manual processes to fully automated dedicated instruments, depending on the frequency of the need to measure M² of lasers and laser systems.
-
product
Current Transformer Tester
CT-T1
The CT-T1 is a microprocessor-based Current Transformer Tester that measures CT excitation current, turns ratio, and winding polarity tests, all without having to switch the leads during testing. The instrument has a fully automatic knee point detection (ASA 10/50, IEEE 30°, IEEE 45°). Although includes 5 low side taps and 1 high side tap.
-
product
Turns Ratio Testing
Weshine Electric Manufacturing Co., Ltd
1. Full three-phase sinusoidal inverter power output, output voltage is automatically adjusted, with soft start and soft stop functions, so the test speed is fast and the accuracy is high.2. The instrument has single-phase, three-phase, Z-type transformers, voltage transformer ratio, group, polarity test functions.
-
product
Standard Ratio Box For Calibration
ST-105
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
product
Transformer Turns Ratio Meters
Vanguard Instruments Company, Inc.
The ATRT-01 S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01 S3 uses the IEEE C57.12.90 measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01 S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers.
-
product
Transformer Turn Ratio Instrument
ART-3D
The ART-3D is high precision instrument designed to measure ratios, magnetization currents, phase-shifting in power transformers, distribution transformers, potential and current transformers, in conformity to IEEE C57.12.90 and CEI/IEC 60076.
-
product
3 Phase Voltage Extension To Turns Ratio Meter
T-REX
The Raytech three phase voltage system option T-Rex is an optional system accessory for 3-Phase transformer ratio meter test sets designed by Raytech (i.e. TR-MARK III). T-Rex was designed to give Engineers and Test Technicians the ability to test the phase relationships and actual voltage ratios of transformer windings while applying three phase voltage.
-
product
Transformer Turns Ratio Meter
TTRM 301
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
product
High Voltage Op Amplifiers ≥12V
High supply voltage op amps are used in systems that demand the widest dynamic range with the best signal-to-noise ratio. Engineers turn to Analog Devices for high voltage amplifiers that deliver industry-leading performance. Increasingly, new high voltage amplifiers also offer features to improve system performance, cost, and robustness while easing the complexity of system design. New features include integrated input overvoltage protection (OVP), on-chip electromagnetic interference (EMI) filtering, higher electrostatic discharge (ESD) immunity, and greater resistance to latch-up in both powered and unpowered operations.
-
product
Fully Automatic Transformer Turns Ratio Tester
DY100
DY-100 is a new generation, fully automatic, transformer turns ratio tester designed for measuring ratio, ratio error of single and three phase transformers. The entire test is done automatically and quickly. Operator enters the test parameters and DY-100 tak es over; powers up the voltage, balances the bridge, takes the readings, and displays the results on the LCD screen. Prints testresults through its built-in printer. A key feature of the DY-100 is automatic measure transformer connection group. LV and HV windings are automatically isolated once the measurement is over. True portability is achieved by the lightweight (only 10 kg), single unit design housing the DY-100. The DY-100 is encased in an aluminum alloy cabinet.
-
product
Turns Ratio Testing
The transformer turns ratio test, or TTR test, confirms that the transformer has the correct ratio of primary turns to secondary turns. Using this test correctly can help to identify tap changer performance, shorted turns, open windings, incorrect winding connections and other faults inside transformers. Megger’s range of TTR testers are robust to withstand the harsh conditions that some transformer testing in. The range includes varying features to simplify and speed up testing as well as 3 phase TTR testers and PT and CT TTR testers.
-
product
Transformer Testing Equipment
Offering you a complete choice of products which include Automatic Transformer Turns Ratio Instruments (ATRI- 3), Automatic Transformer Turns Ratio Instrument (ATRI-201), VTRI-2000 ( Transformer turns ratio instrument ), Current Transformer Test Set (CTC-1), Potential Transformer Tester ( PT Tester ) and Current Transformer Tester ( CT Tester ).
-
product
3 Phase Voltage Extension To Turns Ratio Meter Rack
T-REX R
The Raytech three phase voltage system option T-Rex R is an optional system accessory for 3- Phase transformer ratio meter test sets designed by Raytech (i.e. TR-MARK III R). T-Rex R was designed to give Engineers and Test Technicians the ability to test the phase relationships and actual voltage ratios of transformer windings while applying three phase voltage.
-
product
Mini Automatic Transformer Observation System
mini-ATOS
The mini-ATOS, is a professional multifunctional power transformer and substation diagnostic system. This compact and intelligent instrument can perform many routine and advanced tests such as Winding Resistance (WR), Dynamic Resistance Measurement (DRM), Turns Ratio (TR), Frequency Response of Stray Losses (FRSL), Magnetic Balance, and other diagnostic parameters. With the built-in fully automatic multiplexer, only a one-time connection is required for nearly all functions, which saves a considerable amount of time. The portable, rugged case is perfect for use anywhere onsite or in a laboratory. It is specially designed for fast and easy measurements with the well-known high precision and quality of all Raytech instruments.
-
product
Transformer Turns Ratio Meter
We are considered as one of the leading manufacturers and exporters of Transformer Turns Ratio Meter With/ Without Phase. The equipment is widely used in power generation and engineering industry for testing of transformers. We engineer and develop this testing equipment in accordance with industry standards using best grade components and raw materials. This Transformer Turns Ratio Meter With/ Without Phase can be also optimized according to client's specific requirement. We offer this testing equipment at competitive price.
-
product
50Hz-100kHz LCR Meter
11022/11025
Chroma Systems Solutions, Inc.
0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver
-
product
High-Speed Transformer Test System
DU-7211
Delta United Instrument Co., Ltd.
Inductance, Q factor, Leakage Inductance, AC Resistance, Capacitance, DC Resistance, Balance,Turn ratio, Open/Short check
-
product
Multi-Function Transformer Turns Ratio Tester (TTR)
HTBC-V / 252
Wuhan Huatian Electric Power Automation Co., Ltd.
Suitable for transformer testing of three-phase transformer, z-winding transformer, rectifying transformer and railway electrical system.
-
product
Turns Ratio Meter 3 Phase
TR-MARK III 250V
The TR-MARK III 250V is the successor of the famous TR-MARK III. Besides an extended test voltage up to 250V, it offers new features and increased accuracy to make it a perfect system. A color LCD with back lighting and touch screen increases handling and user comfort. Two USB interfaces make it easy to store measurements on external storage devices and transfer easily to a personal computer or download nameplate data of transformer to test.