Filter Results By:
Products
Applications
Manufacturers
Contact Resistance
opposition to the flow of heat or electricity within a connection.
- Virginia Panel Corporation
product
75 Ohm HD Coax Contact
Ideal for video applications.Used for high definition TV transmission.Can be used in VPC hybrid iCon modules with 20/26 GHz contacts.
-
product
Mini Coax, Contact, ITA, RG178
610103130
Primary mating contact 610104141. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 30µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 milliohms @ 0.5 Amp & always < 10 milliohmsCable Specifications RG178Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Coax, Contact, ITA, 75 Ohm, RG179
610103169
Primary mating contact 610104157. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – brassCenter Contact – BeCuContact Plating Center Conductor Shield - 30µ” Au over 100µ” NiContact Termination Center Conductor – Crimp or SolderShield – CrimpInsulator PTFEMating Force 4.0 lbs max [1.81 kg]Electrical SpecificationsCharacteristic Impedance 75ΩFrequency Range DC to 3 GHzVSWR < 2.95 @ 3 GHzInsertion Loss -1.64 @ 3 GHzDWV 800 VRMSContact Resistance Center Contact is 5 milliohms Outer Contact is 3 milliohmsCable Specifications RG179Environmental SpecificationsOperating Temperature -55°C to +125°CVibration MIL-STD 1344, Method 2005, Test Condition 4Shock MIL-STD 1344, Method 2004, Test Condition AInsulation Resistance 1000 MΩ min.
-
product
Micro Coax, Contact, Receiver, RG316 Double Shield
610140104
Primary mating contact 610141104. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor – SolderShield – SolderInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 10.5 GHzVSWR 1.0225 +.05 f(GHz)Insertion Loss -√f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Signal, Contact, Receiver, TriPaddle, 10 Amp, 14-18 AWG
610110177
Primary mating contact 610110113. (May mate with other ITA contacts, as well.)Specifications Operating Voltage & Current 10 Amps Max. Continuous (14 AWG)600 Volt Max. use of wire Mil-W-16878/4Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 4000 MOhms Min.Contact Body BeCuContact Plating 30µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs.) 0.41
-
product
Dynamic Micro Ohm Meter
PRIME 200
It is the only micro ohm meter in the market that integrates both the contact resistance and the dynamic resistance measurement (DRM) for cost-efficient condition evaluation of contacts in SF6 and vacuum type circuit breakers; PRIME is a high current micro-ohmmeter that provides true pure DC with smart control up to 200 A, a wide measurement range with high power, dual ground testing process, thermal printer, touch display, pre-defined test modes and automatic reporting.
-
product
Auto Contact Resistance Tester
KVHL
KV Hipot Power Test Equipment Co.,Ltd
KVHL Auto contact Resistance Tester with advanced large power switch power technology ang electric circuit is a special measurement instrument for testing the contact resistance of high/low switchs, cable wires and welds.
-
product
6 Contacts- Circuit Breaker Analyzer
CB14
The CB14 is a 6 contacts circuit breaker analyzer designed to perform Timing, Motion as well as Static & Dynamic Resistance Measurement (DRM) in a single test. It also includes 3 multifunction analog inputs.
-
product
Ground Fault Protection Monitors
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
product
600A Digital Clamp Meter
7128C
Peaceful Thriving Enterprise Co Ltd
This is an auto-ranging, high accuracy and stable hand held clamp meter to make electrical maintenance safe and easy. With special designed IC to support true RMS, the meter is available to measure AC/DC voltage to 600V, AC/DC current to 600A and resistance to 60MΩ; also having the capability to test diode, continuity, frequency and non contact voltage sensing. Sub switch included Function Select, Value Hold, Range Select, Relative Value Measurement, Inrush Current Indication, Hz/Duty Cycle, Illumination and Back-light.
-
product
Test System for Detecting Exact PCB Short Circuit Locations
QT25
Qmax Test Technologies Pvt. Ltd.
QT25 employs a unique method to detect exact PCB shorts circuit locations and pin down the shorted components and tracks. It is designed in such a manner that it precisely detects exact short circuit locations across VCC - GND or a shorted component connected across a Bus or hair-line shorts between PCB tracks, Which is highly impossible to detect using conventional tools especially when they are connected parallel in circuit. It can also be used in measuring the contact resistance of switches and relays in its milli-ohm mode as a value add.
-
product
Leaf Wetness Sensors
Campbell Scientific offers two types of leaf wetness sensors to measure the wetness of leaves: surface contact and electrical resistance. Surface contact sensors measure the electrical resistance of a water film on their surface. Electrical resistance sensors imitate the characteristics of leaves and measure the dielectric constant of their upper surfaces.
-
product
100 Ampere Micro OHM Meters
Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester, and uses a test current of 100A DC, resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new, fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100
-
product
Single 16x4 1-Pole High-Density PXI Matrix Module
40-520-403
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
product
Signal, Contact, Receiver, TriPaddle, 7 Amp, 26-28 AWG
610110167
Primary mating contact 610110169. (May mate with other ITA contacts, as well.)Specifications Operating Voltage & Current 7 Amps Max. Continuous (20 AWG)600 Volt Max. use of wire Mil-W-16878/4Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 4000 MOhms Min.Contact Body BeCuContact Plating 30µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs.) 0.41
-
product
Coax, Contact, Receiver, 20/26 GHz, Flex 402
610102119
Coax contact, Receiver, 20/26 GHz, Flex 402 (Only available in patchcords).Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield-SolderInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 26 GHzVSWR 1.25 for 2 - 18 GHz1.30 for 18 - 26 GHzInsertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications Flex 402 (Only Available in Patchcords)Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition AInsulation Resistance 2000 MΩ Min.
-
product
Instrument Transformer Calibrators
MRL 22
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
product
Battery Tester
6470 BT
Standard Electric Works Co., Ltd
2000 counts. DC Voltage measurement. 4-wire resistance measurement. Data hold function. Low battery indication. 9V DC power supply. Measure battery types: Li-ion, Ni-Cd, Ni-MH. Simple operation. Lead resistance and contact resistance eliminated.
-
product
Coax, Contact, Receiver, 20/26 GHz, SF142B, 90 Series modules only
610102109
Primary mating contact 610102110. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield – Crimp/ClampInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 OhmsFrequency Range DC to 26 GHzVSWR 1.15 + .01 (f) GHz w/ SF142 (20 GHz)Insertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications SF142B Environmental SpecificationsOperating Temperature -65°C to +125°Vibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
LXI Low Thermal EMF Matrix 1-pole 28x33
60-510-003
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.
-
product
PXI Single 24x8 Matrix, 2 Pole Switching
40-521-022
Typical applications for this high density matrix include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability rutheniumelectro-plated reed relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, 7 PXI modules will form a 168x8 Matrix, a total of 1344 crosspoints in a 7-slot PXI Chassis. All 40-521 series modules are fitted with reed relays (ruthenium sputtered type), these offer very long life with good low level switching performance and excellent contact resistance stability.Spare Reed Relays are built onto the circuit board to facilitate easy maintenance with minimum downtime.
-
product
Non-contact Ultra-High Range Sheet Resistance Measurement System
CRN-100
*Ultra-High range sheet resistance measurement for 10E+9 ~ 10E+15 ohm/sq without contacting*Mapping program software;*1. Arranged in a multipoint pattern measurement is programmed*2. 2-D & 3-D mapping software*Easy operation by Windows 7 system software*Measurement data base link with Excel via CSV format file*Unaffected by contact resistance
-
product
Circuit Breaker Contact Resistance Meters
Vanguard Instruments Company, Inc.
The Vanguard Auto-Ohm 10 is a 10-ampere battery powered micro-ohmmeter designed for low-resistance-measuring applications such as the measurement of resistance in circuit breaker contacts, bushing contact joints, and welding joints. The unit is powered by four 3400mAh, 3.7Vdc Li-Ion rechargeable batteries. With these high capacity batteries, up to 2,900 tests per charge (10A/2 second duration) can be performed in the field.
-
product
Signal, Contact, Receiver, TriPaddle, 10 Amp, 14-18 AWG
610110128
Primary mating contact 610110129. (May mate with other ITA contacts, as well.)Specifications Operating Voltage & Current 10 Amps Max. Continuous (14 AWG)600 Volt Max. use of wire Mil-W-16878/4Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mAContact Body BeCuContact Plating 50µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 0.41
-
product
Dynamic Micro Ohm Meter
PRIME 600
It is the only micro ohm meter in the market that integrates both the contact resistance and the dynamic resistance measurement (DRM) for cost-efficient condition evaluation of contacts in SF6 and vacuum type circuit breakers; PRIME is a high current micro-ohmmeter that provides true pure DC with smart control up to 600 A, a wide measurement range with high power, dual ground testing process, thermal printer, touch display, pre-defined test modes and automatic reporting.
-
product
Mini Coax, Contact, ITA, 22 AWG
610103172
Primary mating contact 610104160. (May mate with other Receiver contacts, as well.)Specifications Characteristic Impedance 50 OhmsFrequency Range DC to 1 GHzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzVSWR ≤ 1.06 @ 1 GhzOperating Voltage & Current 0.5 Amps Max. ContinuousDielectric Withstanding Voltage (DWV) 1500 VDC Min.Insulation Resistance 1000 MOhms Min.Contact Body Female & Male (RCV & ITA) – shield – brass, center conductor – BeCuContact Plating Center conductor – 60µ" Au over 100µ" Ni; Shield – 50µ" Au over 100µ" NiContact Termination Center Conductor – CrimpShield – Not ConnectedCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force 1.02
-
product
Test Setup For Air Conditioner
SCR ELEKTRONIKS have developed TESTING SET UP FOR SINGLE PHASE / THREE PHASE MOTOR for carrying out Performance Test, Earth Contact Resistance Test, High Voltage Test, Megger Test and Leakage Current Test. It consists of Voltmeters, Ammeters and Wattmeters for observing the values of different parameters. OK / NOT OK lamps are also provided to display the results of Earth Contact Resistance Test, HV test, Megger Test, Leakage Current Test. All tests are provided with tripping cut off concept.
-
product
Contact Resistance Measurement Kit
LRM-10
The LRM-10 is a 10A micro-ohmmeter kit designed to measure low resistance for electrical interconnections integrity testing. The LRM-10 has a range from 0.01µΩ to 200Ω. It comes with heavy duty four points probes and it is compatible with a great variety of optional accessories.
-
product
PXI Single 32x8 Matrix, 1 Pole Screened
40-531-021-S
Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.
-
product
Micro Coax, Contact, Receiver, RG316
610140101
Primary mating contact 610141101. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 3 GHzVSWR 1.22 @ 3 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outerCable Specifications RG316Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Microohmmeter
Used to measure extremely low resistances with high accuracy at specified test currents and is used for contact and bonding applications.