Filter Results By:
Products
Applications
Manufacturers
2-wire
resistance measurement method.
-
product
Interface
RAR-PCIE
Available in a range of configurations to match your needs, RAR-PCIE provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols.
-
product
Keysight Dual 4x16 Armature Matrix for 34980A
34932A
The Keysight 34932A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x16, 8x16, or 4x32 configurations 128 2-wire cross-points 300 V, 1 A switch; 2 A carry current Connections to the internal DMM Latching armature relays, with relay counter Expandable via four 2-wire analog buses
-
product
Door Contact Sensor
ENVIROMUX-M-DCS
Monitors access with a magnetic bridge sensor, which responds to any magnetic material (no special inserts necessary). Can also be used for monitoring side wall and covers. Includes mounting hardware. For normally closed circuit connection. 2-wire interface. Screw terminal. Maximum cable length: 1,000 ft. Wide actuating gap, approximately 1". Dimensions WxDxH (in): 0.5x0.5x2 (Switch), 0.5x0.5x2 (Magnet). Operating temperature: 32 to 158°F (0 to 70°C). Regulatory approvals: RoHS.
-
product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 or 2-Wire Dual 4×32 Matrix Matrix Topology Without Column Protection Resistors
782385-13
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
PXI High-Density Multiplexer: 64-ch, 2-Wire, 100Vrms/1A, Reed Relays
M9101A
The M9101A, a high-density, 64-channel PXI multiplexer routes many different channels to a single point. The switches operate in a break-before-make mode that ensures no two points are connected at the same time or, if needed multiple channels can connect simultaneously. Ideal for routing multiple analog signals to a measurement device in automated test environment (ATE) or data acquisition systems. Each channel switches a high and a low for 2-wire switching up to 100Vrms, with up to 10W of power. Connection options include the durable connector block or the standard cable connections.
-
product
Serial Interface Device
The Serial Interface Device offers a number of options for connecting to serial hardware. You can choose from Ethernet, USB, PCI, PCIe, or ExpressCard interfaces to add up to 16 serial ports to your system. You can choose from common serial protocols, such as RS232, RS422, and RS485. The Serial Interface Device also offers various isolation, hyperthreading, and multiprocessor compatibility options. Some models also support 4- and 2-wire transceiver modes for full- and half-duplex communication. NI serial interfaces also appear as standard COM ports for compatibility with programs that use serial communications.
-
product
ANSI X3.28 to Modbus RTU Converter
Model 2399
* Converts ANSI X3.28 commandslinto Modbus RTU packets.* New 32 Address Mode supports multi-channel Modbus Controllers like the Watlow MLS300.* Control Modbus RTU devices from any ASCII serial source.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes serial baud rate conversion.* Internal logic is IEEE-488.2 compatible and uses SCPI commands for configurtion setup.* 2399 mounts on a DIN rail or on any flat panel.* Inexpensive way to maintain manufacturing equipment such as semiconductor fusion chambers, etc as the ANSI Controllers become obsolete.* Application Note AB23-3 describes how to use the 2399 to replace obsolete Watlow Controllers in the Axcelis/Fusion Gemini Asher.* 2399 Serial Keyboard Program lets you control and setup the 2399 and test the ANSI modes.* 239x Table Loader Program uploads ANSI Command Table entries from an Excel csv file.
-
product
NI TB-2641B Terminal Block for NI 2532B as 1-Wire 8x64 Matrix Topology Without Column Protection Resistors
782385-03
The TB-2641B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 4x128 matrix. You can directly connect the TB-2641B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2641B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
NI TB-2645B Terminal Block for NI 2532B as 1-Wire Dual 16x16 Matrix or 2-Wire 16×16 Matrix topology With Column Protection Resistors
782385-12
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
Proximity Sensors
Cutler-Hammer® proximity sensors that deliver the results you're looking for. Choose from photoelectric sensors, 2-wire AC and 3-wire DC inductive sensors, sensors with LED indicators, and more.
-
product
Interface RS-485 and RS-422
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
product
Digital And Analog Call Simulation
GL’s T1 E1/Analog Test Suite supports analysis and emulation of legacy protocols (MFCR2, E&M, SS1/SS4, SS5, Voice Call Signaling, 2-wire Call, SF Signaling (DTMF)) applicable to Federal Aviation Administration "FAA" within their National Airspace System "NAS" Ground-to-Ground Air Traffic Control Network and Voice System (NVS) to Analog Interphone.
-
product
Loop Calibrator
MS-420
The Loop Calibrator is a multi-purpose process loop tool that offers high accuracy in an ultra-small, rugged package. A single pushbutton selects one of five current outputs (4, 8, 12, 16 or 20 mA), which can drive up to 300 Ohms, or can act as a 2-wire simulator with an external loop power supply of up to 30 VDC.
-
product
Industrial Grade PCI DIO 96 Board
MS 1817
*96 digital input/output lines*Support s all PPI Modes (Mode0, Mode 1 and Mode 2)*5 V TTL/CMOS*Compatible with NI DIO Card*2-wire handshaking capability*Known power-up
-
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
product
Interface
RCEI-530
Available in a range of configurations to match your needs, the RCEI-530 provides complete, integrated databus functionality for ARINC 429, ARINC 575 and selected 2-wire, 32-bit protocols. The RCEI-530 supports maximum data throughput on all channels while providing onboard message scheduling, label filtering, multiple buffering options, time-tagging, error detection and avionics-level I/O discretes, with support for either 33 MHz or 66 MHz PCI interfaces.
-
product
In-Line IR Sensor
ILA
10:1 Distance to Target Ratio, 32 to 932F. Dwyer Series ILA Non-Contact Sensors, measure temperatures from 32 to 932F (0 to 500C) and provide a linear 4 to 20 mA, 0 to 5 VDC or thermocouple output. The 2-wire signal is compatible with almost any indicator, controller, recorder, data logger, etc., without the need for special interfacing or signal conditioning.
-
product
Switch Mainframe
SW1002
Switch between voltmeter and battery tester while testing. 264 channels max. (2-wire) to 72 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.
-
product
NI TB-2644B Terminal Block for NI 2532B as 1-Wire Dual 8x32 Matrix or 2-Wire 8×32 Matrix topology With Column Protection Resistors
782385-10
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
PXIe-2737, 256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module
782835-37
256-Crosspoint, 4x64, 2-Wire PXI Matrix Switch Module—The PXIe‑2737 is a high‐density 4x64 PXI matrix switch module designed for routing signals within automated test systems and using electromechanical relays to perform immediate switch operations. It also offers features to monitor the health of deployed systems and plan for predictive maintenance, including onboard relay count tracking, a temperature sensor, and functional and resistive relay self-tests available through the NI Switch Health Center.
-
product
Digital Power Recorder
MPR-601W-02
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Applicable for single phase 2wires and single phase 3wires and 3phase 3wires system*Wide measuring range up to 0~500V/500A*Easy data logging by USB flash memory
-
product
Cable and Harness Tester
CHT
The Cable and Harness Tester (CHT) provides multiple testing capabilities for up to 300 connector/harness test points. Test capabilities include DC Insulation Resistance (IR), DC and AC Dielectric Withstanding Voltage (DWV), and 2-Wire and 4-Wire Continuity.
-
product
NI TB-2644B Terminal Block for NI 2532B as 1-Wire Dual 8x32 Matrix or 2-Wire 8×32 Matrix Topology Without Column Protection Resistors
782385-09
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
product
Signal Conditioners
Process transmitters isolate, filter amplify, and convert sensor signals to 4-20mA current or 0-10V voltage signals for interfacing with controllers and other instrumentation. Select from 2-wire loop-powered 4-20mA transmitters, 3-wire DC-powered transmitters, or 4-wire AC/DC-powered transmitters. 3-wire and 4-wire models are available as 4-20mA transmitters or voltage transmitters. DIN-rail and field-mount version are available. Configuration is easy with Windows software, push-buttons, switches, or pots for span/zero settings depending on the series.
-
product
4 Wire Earth Resistance Testers
4234 ER
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Earth testing at 2Ω, 20Ω, 200Ω, 2kΩ.● Earth voltage measuring : 0-300V AC.● Automatic C spike check.● Automatic P spike check.● 2-Wire test.● 3-Wire test.● 4-Wire test.● LCM display.● Auto ranging.● Auto power OFF.● Data hold.● Robust, compact and easy-to-carry.
-
product
TB-2635, Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block
778839-01
Screw Terminal, 8x16, 2-Wire PXI Module Matrix Terminal Block - The TB-2635 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 8×16 matrix. You can directly connect the TB-2635 to the front panel I/O connectors of the PXI-2529. The TB-2635 includes screw terminals that provide access to the rows and columns of the matrix.
-
product
Switch Mainframe
SW1001
Switch between voltmeter and battery tester while testing. 66 channels max. (2-wire) to 18 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.
-
product
Legacy Liquid Detection Rope Sensor
ENVIROMUX-LDSx-y
For warning of flooding. Detects liquid depth >0.1" (2.5 mm). Minimum puddle: 0.6" (15 mm) diameter. 100% waterproof electronics. Detects any liquid or moisture, except deionized water. RJ45 connector. Voltage Supply: 12VDC. Current Consumption: 20mA. Supports CAT5/5e/6 cable up to 1,000 ft. (305 m). Available water sensor cable (x) lengths: 1/10/50/100/200/400/600/800/1000 feet. Plenum rating: CL2P (UL). Available 2-wire cable (y) lengths: 5/10/20/50/100 feet. Powered by ENVIROMUX-SEMS-16U and SERIMUX-S-x. Regulatory approvals: CE, RoHS. Requires the ENVIROMUX-SEMS-16U and SERIMUX-S-x to operate. Use self-adhesive clips (ENVIROMUX-CLP10-LD) to prevent sensor rope cable from shifing after installation. ENVIROMUX-CLP10-LD includes 10 clips.
-
product
SWB-2814, 8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock
781421-14
8x9, 1 A, 2-Wire Reed Matrix Module for SwitchBlock - The SWB‑2814 is a reed relay matrix module for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
product
4 Wire Earth Resistance & Resistivity Tester
4235 ER
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Earth resistivity (ρ) test.● Earth testing at 20Ω, 200Ω, 2kΩ.● Earth voltage measuring : 0-300V AC.● Automatic C spike check.● Automatic P spike check.● 2-Wire test, 3-Wire test, 4-Wire test.● LCM display.● Auto ranging.● Auto power OFF.● Data hold.● 200 measurement results can be saved in the memory and recalled on the display.● Interval between auxiliary earth spikes is 1.0~50.0m.