Filter Results By:
Products
Applications
Manufacturers
Harmonic
Sinusoidal component of a perodic wave or for a sine wave, it is an integral multiple frequency of the wave.
-
product
Harmonic Analysis Software
HI_WAVE
HI_WAVE simulates resonance and harmonic distortion in industrial, commercial, and utility power systems.
-
product
UX Range Broadband Power Amplifiers 2 GHZ - 6 GHZ
UX Series
Class A solid stateBroadband (instantaneous single band): 2 GHz 6 GHzTypical output power : 15 W CWLinear output power (1 dB compression) guaranted with harmonics <-20dBc:P1dB > 12 W and H < -20 dBc up to 4 GHz andP1dB > 11 W and H < -20 dBc from 4 GHz to 6 GHzAir cooling: self contained fansCan operate in full mismatch conditions without damageUpgradable to UX 30 possible (4U)Reliable, efficient and robust19" Rack3 years standard warranty
-
product
PXI-2597, 26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module
778572-97
26.5 GHz, 50 Ω, 6x1 (SP6T) Terminated PXI RF Multiplexer Switch Module—The PXI‑2597 is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules. The internal termination of the PXI‑2597 helps prevent high-power reflections that arise from open channels on the module. You can use the PXI‑2597 onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
product
Single Channel Signal Conditioner
SAM-3
Macintyre Electronic Design Associa
The SAM-3 is a portable single channel signal conditioneer specifically tailored to provide power to and process the signals from MEDA's line of AC magnetic field sensors. The unit operates from eitherits internal batteries or the power line. It incorporates two sets of power line rejection fileters, switch selectable fro 50 to 60 Hz and the corresponding first four harmonics.
-
product
Three Phase Power Analyzer
930A
Model 930A Three Phase Power Analyzer is an economical alternative to the Model 931A Power System Analyzer when the dc voltage measurement, transducer calibration and timer features are not required. The Model 930A has the same ac accuracy as the Model 931A with PowerDSA™ Digital Signal Analysis. Basic accuracy of 0.05 % of reading and 0.05 ° phase, harmonic analysis, and full three-phase capability are standard.
-
product
PICMG® 2.11 47-pin Hot-Swap Redundant 3U CompactPCI® 8HP 250 W Power Module
cPS-H325/110
- PICMG® 2.11 CompactPCI® Power Interface compliant- Internal OR-ing Diodes for N + 1 redundancy- PICMG® 2.11 47-pin CompactPCI® in-rack power module interface- 250 W DC output- Active PFC (Power Factor Correction) meets IEC1000-3-2 Harmonic Correction
-
product
High-Reliability Voltage Controlled Oscillators
16 Models with Frequency Bands ranging from 10 MHz to 4350 MHz. 0.5" Hermetically Sealed Surface Mount Package. 50 Ohm Internal Matching. Designed to meet MIL-STD-883 and MIL-STD-202 Test Conditions. Wide Voltage Tuning Range from 0.5V to 20V. Phase Noise as low as -120 dBc/Hz @ 10 KHz offset. 2nd Harmonics as low as -25 dBc. RoHS and REACH Compliant. All models are EAR99. These products are used in military electronics, SATCOM, test and measurement and wireless communications.
-
product
LCL Filters
LCL Type Harmonic Filter Modules are used to filter out the input current harmonics of the Motor Drives having six-pulse diode/thyristor rectifiers, where harmonic current distortion exceeds the limits defined in standards.
-
product
Microwave Downconverter, 3 GHz to 26.5 or 110 GHz
E5053A
The E5053A microwave downconverter is designed to operate with the E5052A/B signal source analyzer (SSA). When configured with the E5053A microwave downconverter, the E5052A/B SSA offers exceptional phase noise sensitivity up to 26.5 GHz. Additionally, combining a pair of 11970 series harmonic mixers offers the phase noise measurement up to 110 GHz.
-
product
Harmonic/Flicker Analyzer for IEC61000-3-2/3/11/12, IEC61000-4/7/15
KHA3000
KHA3000, in addition to the complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase*. Furthermore, the KHA series is compliant with two measurement technique standards, the existing and the latest versions, so you can simply select to take measurements for the latest standard including interharmonics and for the conventional integral multiple harmonics without using any other device. In addition to the real-time display that can be used like an oscilloscope and FFT analyzer, the unit offers the real-time judgment of compliance with standards. Using this unit alone, you can judge test results and prepare result reports without the use of a PC. On top of that, you can easily set up a test system by combining KHA3000 with an AC power supply (PCR-LA Series) and a line impedance network (LIN40MA-PCR-L).
-
product
Loggers/PQA
Kyoritsu Electrical Instruments Works, Ltd.
Large capacity for storing 60,000 data points Lowpass Filter will filter out the harmonics LED flickers when the preset current/voltage value is exceeded CALL:Confirmation of recorded data Selection of One-time mode or Endless mode Non Volatile Memory Battery power indicator The userfriendly PC software "KEW LOG Soft 2" is supplied Continuous measuring time:Approx. 10 days (Alkaline Battery)
-
product
Portable Test System
MT786
Actual value, vector, curve displayCurrent and voltage generationerror measurementMeasurement of harmonics up to the 40th
-
product
RF & Microwave Signal Generator
SMA100B
The R&S®SMA100B RF and microwave signal generator delivers uncompromising maximum performance. It provides the purest output signals while maintaining the highest output power levels with the lowest harmonics, far outpacing the competition. As the world's leading signal generator, it can handle the most demanding module and system T&M tasks in the RF semiconductor, wireless communications, aerospace and defense industries.
-
product
Sound Harmonics and Current Analyzer
H74050100
This analyzer is used as end of line control for electro mechanic components with electric motors, with or without mechanical reduction. While the motor is running at nominal speed, a spectrum and temporal analysis of the sound as well as a current consumption test is performed. Statistical analysis of the data acquired is also performed real-time, expediting the PASS/FAIL decision of the DUT.
-
product
Voltage Controlled Oscillators
a High Reliability Low Noise Voltage Controlled Oscillator (VCO) which covers a 10 MHz to 20 MHzfrequency band with a voltage tuning range from 0V to 20V. This design features exceptional phase noise performance of -120dBc/Hz @ 10 kHz offset. Supply Voltage is +15V with a generated output power level of +10 dBm and 2nd harmonic output of-11 dBc typical. The assembly is RoHs compliant and available in a compact 0.5 inch SMT package with an industry standardmounting footprint. The bottom surface is copper clad with 2-5 micro inches of immersion Gold over 150 - 250 micro inchesof Electro less Nickel which makes it resistant to oxidation for ease of soldering. The VCO operates over a temperature rangeof -40°C to +85°C and is designed to meet a variety of MIL-STD-202 test conditions including Humidity, Shock, and Vibration.
-
product
Ultra-Low Distortion Function Generator
DS360
Stanford Research Systems, Inc.
The performance of a low distortion analog source and the precision of direct digital synthesis (DDS) is combined in the DS360. With less than 0.001 % total harmonic distortion (THD), 25 ppm frequency accuracy, and a broad range of features including sweeps and bursts, the DS360 is the ideal source for audio frequency applications.
-
product
sbRIO-9225, Non-Enclosed, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module
780588-01
Non-Enclosed, 300 Vrms, 50 kS/s/ch, 24-Bit, Simultaneous Input, 3-Channel C Series Voltage Input Module - The sbRIO‑9225 performs differential analog input. The wide measurement range is well suited for high-voltage measurement applications such as power metering, power quality monitoring, motor test, battery stack testing, and fuel cell tests. You can perform transient and harmonic analysis with high-speed simultaneous sampling. In addition, you can prevent ground loops and add safety to a system with 600 Vrms channel‑to‑channel isolation between the three sbRIO‑9225 channels. Non-enclosed modules are designed for OEM applications.
-
product
Multifunction Installation Testers
Shanghai Beha Electronics Co., Ltd.
Loop impedance and prospective short circuit current measurement• Line impedance and prospective short circuit current measurement• Earth loop resistance in TT-systems• Rotary field test• RCD measurements (contact voltage, trip time, trip current - ramp method)• RCD analysis for test of all RCD parameters • Low Ohm and continuity measurement • Insulation measurement up to 1000V (suitable for 690 V industrial mains systems)• Earth resistance measurement with probes and clamp adapters• Voltage and frequency measurement • Current measurement with clamp adapters(optional)• Power and energy measurements• Harmonics measurement for voltage and current upto the 21st harmonics
-
product
PXI RF Relay Module
PXI RF Relay Modules offer single-pole double-throw (SPDT) and terminated switches. SPDT models include excellent insertion loss, voltage standing-wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay-count-tracking feature on these models to predict relay lifetime and reduce unexpected system downtime. SPDT models are also well-suited for passing high-order harmonics from PXI RF Signal Upconverter Modules or routing multiple sources to PXI RF Signal Downconverter Modules. Terminated switch models feature front-mounted SMA connectors and high-performance solid-state relays for fast switching time and unlimited mechanical lifetime. These models also include termination on every COM line and channel, which helps minimize reflections of the RF signal and protect your instruments.
-
product
Waveguide Harmonic Mixers (Smart Mixers), 55/60 to 90 GHz
M1971E
Keysight M1971E 55/60 to 90 GHz waveguide harmonic mixers is an un-preselected mixer provides a complete solution for wideband millimeter-wave signal analysis of more than 2 GHz with X-Series signal analyzers. Smart features are embedded to help you to greatly simplify your overall test setup and improve the DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.
-
product
Operational Amplifiers
Operational amplifiers from ams are ideally suited to audio applications. These CMOS devices are available as single, quad or differential amps. They feature good common-mode rejection, have low input bias currents, good gain bandwidth, low total harmonic distortion and an excellent rail-to-rail output-drive capability of 200mA peak.
-
product
ANSI Standard Burden Sets
Voltage and Current
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
product
Voltage Variable Attenuators
a High Reliability Low Noise Voltage Controlled Oscillator (VCO) which covers a 10 MHz to 20 MHzfrequency band with a voltage tuning range from 0V to 20V. This design features exceptional phase noise performance of -120dBc/Hz @ 10 kHz offset. Supply Voltage is +15V with a generated output power level of +10 dBm and 2nd harmonic output of-11 dBc typical. The assembly is RoHs compliant and available in a compact 0.5 inch SMT package with an industry standardmounting footprint. The bottom surface is copper clad with 2-5 micro inches of immersion Gold over 150 - 250 micro inchesof Electro less Nickel which makes it resistant to oxidation for ease of soldering. The VCO operates over a temperature rangeof -40°C to +85°C and is designed to meet a variety of MIL-STD-202 test conditions including Humidity, Shock, and Vibration.
-
product
Power & Energy Analyzer
PS3550
The PowerSight PS3550 Power Analyzer is a versatile, easy-to-use 3-phase power analyzer that is ideal for energy audits, load studies, harmonic analysis, and more. The PS3550 couples its small size with a wide range of operating modes and measurement accessories to help you get the measurements you need, both now and into the future.
-
product
Measurement
AC Selective Voltmeter
AC Selective Voltmeter is used for measuring AC voltage coming to the input channels of ADC modules and FFT spectrum analyzers. The specific feature of the AC selective voltmeter is perfomance of voltage measurements on the main signal-carrier frequency, which allows to eliminate the harmonics influence on the readings.
-
product
Power Analyzers
At PCE Instruments you will find a power quality analyzer to measure the power in W, kWh or to analyze and measure harmonics. This power analyzer is a multi-function power analyzer device that measure precisely direct current, alternating current, AC-voltage, DC-voltage the intensity of DC or AC, phase rotation and idle, apparent and effective power. The reading of AC power is considered the real value and has a maximum range of 6000 Watts. While a reading is being taken, the polarity changes automatically, if negative values are taken then a minus sign will appear on the device display.Nowadays, power quality analyzers have many features such as, insulated current input, measurement of harmonics, AC and DC current measurement, AC and DC voltage measurement, frequency measurement, phase rotation measurement and idle, apparent and effective power measurement. All this data can also be logged and analyzed with the delivered PC-Software. Power analyzers of the type PCE PA 6000 can determine the energy in single-phase systems.Power quality analyzers of type PCE-GPA 62 allow the energy measurement in symmetrically loaded three-phase systems. Power analyzers of type PCE-PA 8000, PCE-360 and PCE-830 support professional power and energy measurements in single and three-phase systems.Apart from being used as energy-measuring devices, power analyzers like the PCE-830 can also be used for network analysis and the determination of harmonics and phase rotation. On our website you will find other power analyzers used in the field of electronics.
-
product
Harmonics & Flicker Analyser
AC2000A
The Laplace Harmonics and Flicker analyser provides the user with a complete system for testing product compliance with IEC61000-3-2 and IEC61000-3-3. Quick and easy to use, the built-in screen provides a clear pass/fail indication of compliance status, plus a full listing of results for each harmonic, in either tabular of bargraph format. The instrument is properly configured to cope with fluctuating harmonics. The Flicker mode provides proper measurement of short term and long term parameters, using algorithms specified in IEC61000-4-15. In addition, inrush current measurements can be automated such that the product under test can be automatically cycled on/off with user entered time profiles.
-
product
Waveguide Harmonic Mixer (smart mixer), 75 to 110 GHz
M1971W
Keysight M1971W 75 to 110 GHz waveguide harmonic mixer is an un-preselected mixer that provides a complete solution for wideband millimeter-wave signal analysis of more than 2 GHz with X-Series signal analyzers. Embedded smart features help you to greatly simplify your overall test setup and improve the DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.
-
product
PXI-2796, 40 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module
782356-01
40 GHz, 50 Ω, Dual 6x1 (SP6T) PXI RF Multiplexer Switch Module—The PXI‑2796 offers a high-density, unterminated multiplexer with dual 6x1 multiplexer banks in the same module. It is ideal for passing high-order harmonics from PXI RF Signal Upconverter modules or routing multiple sources to PXI RF Signal Downconverter modules.
-
product
Power Analyzer With Harmonics
Measurements of AC and DC parameters with ripple, data logging in it's internal memory and pendrive with ripple.