product
Integrated Potentiostat and Multiplexer
EmStatMUX8
Based upon the EmStat range, there are two types of multiplexers to suit most types of sensor array work. The MUX8 is the most flexible offering the ability to connect arrays made of up to eight working electrodes in two or three electrode cell types and chips sharing a reference electrode and/or counter electrode. The MUX16 is suitable for sensor arrays or chips with sixteen working electrodes all sharing a RE and/or a CE. Both instruments are suitable for laminated layer corrosion analysis.The potentiostat is controlled and powered by USB and is used with PSTrace allowing for simultaneous sampling of each channel at a rate of 25 ms/channel. Standard packaging includes a shielded cable with connections for a working, a counter and a reference electrode by means of 2 mm banana connectors and mini-crocodile clips, a stripped end, Dsub-37 terminated flat cable and a USB cable. To make connections to chips simpler the Connection Terminal is an optional extra providing clearly marked screw terminals to the electrodes and can be directly joined to the ESMUX via their D-Sub connectors.
-
product
Meter With pH Electrode, Conductivity Probe
PC 2700
Your all-in-one solution for multi-parameter research work in the lab! The new PC 2700 is accurate, reliable and intuitive with user-friendly functions. Meter comes with a multi-data screen that includes Temperature, electrode status, calibration points, date and time along with your desired measurement parameter
-
product
Waterproof Handheld Meter with pH electrode
CyberScan PCD 650
A Eutech Star Buy! Combining the strengths of all CyberScan 600 series meters, the CyberScan PCD650 is our top-of-the-line waterproof handheld that enables concurrent measurement of pH, conductivity, dissolved oxygen and temperature, all at the same time.
-
product
Dielectric Material Test Fixture
16453A
The 16453A is designed for accurate dielectric constant and loss tangent measurements on the E4991A/4291A/B. It employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. The E4991A/4291A/B measures the capacitance created from the fixure, and option 002 firmware calculates the relative complex permittivity as described in the 16451B. Adjustment to insure parallel electrodes is required when using the 16451B. This adjustment is not required with the 16453A because the fixure has a flexible electrode that adjusts automatically to the material surface.
-
product
Plasma CVD & Etching Systems
MODEL DRIE-1000
A High Quality Plasma Deposition & Etch System, Ideal for R&D and Small Scale Production. Modified designs with capabilities of 12" wafers. Substrate heating to 500 C. Top loading / Optional loadlock. Multifunctional plasma network. Diversified pumping configurations. Variable electrode spacing. Customized features and components for specific applications.
-
product
AA Neon Tube Tester
West Coast Custom Designs, LLC
When the antenna is touched to the tubing wall or electrode wires, the tester will cause the viable tubing to illuminate in a pulsating manor. This pulsing feature is fantastic for testing neon in bright sunlight as it is easier to see the light when flashing.
-
product
(RDE-OES) Elemental Analyzer
SpectrOil 100 Series
The SpectrOil 100 Rotating Disc Electrode Optical Emission Spectrometer (RDE-OES) is the eighth generation of the market leading RDE elemental spectrometer. It is widely used in commercial oil laboratories, on-site or trailer labs, as a proven means of precisely determining elemental composition in lubricating oil, coolant, light or heavy fuels, grease, and process water. It is also a key component of Spectro’s MiniLab Series of on-site oil analysis solutions, including the best selling MiniLab 153.
-
product
Spark Testers
Range of portable and hand-held AC spark testers, kits, accessories and electrodes which are all specifically configured to suit a range of test applications.
-
product
TTC-1 Tracking Test Chamber
TTC-1
It is according to IEC60695 and IEC60112 (GB4207), the Tracking Test Chamber TTC-1 is intended for determining the degree of protection against formation of conducting paths in solid insulating materials, due to the electric stress and electrolytic contamination of the surface. This method simulates tracking currents on insulation material by providing drops between electrodes. During the process of normal use, insulating material may be exposed to moisture and dirt, if conductive, may cause stress and fire hazard.
-
product
Sensor Products: Weld Force Gage
90061
Model 90061 is a self-contained, portable measurement system which allows auditing of the pinch force generated between the electrodes of resistance spot welders. Resistance welding uses a pair of electrodes to clamp two base metals firmly together prior to and during application of electrical current. Poorly clamped parts result in a defective joint. A correctly clamped assembly aids in reducing the resistance in the joint and allows the current flow to properly heat the base metals to weld the part.
-
product
Earth Testers
Sanwa Electric Instrument Co., Ltd
Most facilities have grounded electrical systems, so that in the event of a lightning strike or utility overvoltage, current will find a safe path to earth. A ground electrode provides the contact between the electrical system and the earth.
-
product
Miniature Two-Point Probe Set
PRF-922B
The PRF-922B Miniature Two Point probe accurately measures point-to-point resistance of small areas. Like Prostat's PRF-912B Miniature Concentric Ring, the PRF-922B is capable of measurements up to 1.0x1012 ohms. Built-in distance stops provide consistent electrode to sample pressure for developing repeatable measurements. Use the PRF-922B to measure small material samples, hard to assess molded areas, edges of parts, tray or tape cells and other very small objects and surfaces. The assembly is supplied with replaceable conductive electrode covers to enhance contact resistance on irregular surfaces and composition materials. Thus, measurements may be made with either the gold plated electrode contacts, or via conductive rubber covers.
-
product
Open Flanges Test Rig
Flexible cell dimensions: cells of Ø 8 to Ø 80 mm (or square till 70x70 mm) can be successively installed Quick start of experiment: less than 20 minutes to remount a new cell with different dimension, thanks to the simple design without sealing Other SOFC components: the open flanges test rig is also useful for conductivity measurements (electrolyte, electrode material, interconnect etc.) and sealing tests End of broken cells and secure testing: the cell is squeezed by a soft alumina felt that prevents any damages, the excess fuel burns continuously in the alumina felt at the cell edges
-
product
Soil Volumetric Water Content
HD3910…
The probes HD3910.1 (two electrodes) and HD3910.2 (three electrodes) measure the soil volumetric water content (VWC) by using a capacitive measurement principle which allows fast measurements in the field and with minimal invasiveness.
-
product
Preamplifier
2721
Pre-amplification is required to protect the output signal of pH and ORP electrodes from a wide variety of electromagnetic interferences common in industrial environments. Signet 2721 is used if remote pre-amplification is required (e.g. tank temperature >80oC) or connecting another manufacturer's electrode to the Signet 5700 or 8750 instrument. The Signet 2721 should be used with special order sensors built with cables (Signet models 277X-HT or 277X-1-HT).
-
product
250 and 260 Series pH Handheld Meter Kits
Get easy-to-read and accurate readings with auto-hold, auto-stable, and real-time measurements with stability indicators. The Environmental Express® Oakton® 200 series of water quality meters features an electrode status indicator, which shows the condition of the electrode after each calibration. Easily view electrode condition, reading stability, measured parameter, and temperature in one screen. Don’t worry about accuracy in fluctuating temperature—ATC ensures measurement accuracy. The simple user interface features adjustable auto shut-off time ranging from 1 to 30 minutes. Self-diagnosing meters display measurement and meter issues for fast fault finding and troubleshooting. Easily take measurements and conveniently store meter and electrodes with built-in foldable stand on the back of the meter. Two grooves on the side of the meter serve as electrode holders, to hold up to 2 electrodes. Choose from two series—the 250 series feature 500 data points (scroll thru on meter) while the 260 series features 1000 data points, a real-time clock, and USB communication for data down loads.
-
product
MANIFULATOR
As one of the most important module in Probe_Station, manipulator is an accurate system that probe micro distance() and contact on the electrode of semiconductor wafer, device. ECOPIA's Manipulator is very easy to use and probe arm's elastic plate is good to protect sample's surface, from being damaged by Z direction movement.
-
product
Analog Tank Test Kit
4108
The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.
-
product
Resistivity Tomography System
WGMD-60 2D
WGMD-60 geo-electrical 2D electrical tomography device is the new developed two-dimention electrical resistivity imaging (ERT) system, which integrated electrode switching and 200v transmitting high power in the mainframe. It support max 60 electrode switching.The whole system features light weight and high stability. It widly applys for different resistivity mapping or geopysical surveys as landslide survey, groundwater investigation, enginnering exploration and so on.
-
product
Handheld Water Quality Meters
LAQUA EC210
- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Automatic / manual temperature compensation and temperature calibration function- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- °C & °F temperature readings- Auto log data; built-in memory can store up to 500 data - Auto stable, auto hold, and real-time measurement modes- Auto shut-off (programmable: up to 30 minutes)- Monochrome LCD with white LED backlight: 50 x 50 mm- Powered by 2 x AA batteries - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Packaged with electrode and calibration solutions in carrying case- 3 years meter warranty
-
product
Bulk Acoustic Wave Technology
BAW
Macom Technology Solutions Holdings Inc.
MACOM’s BAW product portfolio is ideal for high performance Industrial, Aerospace, Defense, and Communications applications that require critical frequency filtering. Our high-performance RF filters enable our customers manage signal integrity in the 1 to 6 GHz frequency range. Bulk Acoustic Wave Resonators consist of two metal electrodes above and below a layer of a piezoelectric material. The piezoelectric material converts an electrical signal to a mechanical signal and vice versa. The metal electrodes provide the connections to/from the piezo material. The frequency at which resonance occurs depends on the thickness of the combined metal-piezo-metal stack. Advances in thin-film piezoelectric fabrication have enabled BAW resonators to meet RF filtering challenges up to 6000 MHz using standard MEMS fabrication process. High-performance BAW resonators-based RF filters are made of piezoelectric material having high Q-factor (>3000) and high coupling coefficient. Currently, no competitive technology provides the same high performance for RF filter applications when compared to BAW resonator-based RF filter up to 6000 MHz for the same size and cost.
-
product
Electrodes
Delmhorst offers a wide assortment of electrodes known throughout the industry for their durability. All Delmhorst electrodes fit any Delmhorst moisture meter.
-
product
Handheld Water Quality Meters
LAQUA PC220
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
product
Panel-mount Type pH Meter (Four-Wire Transmission, 4 point ararm, Time sharing Proportional Control)
HP-960FTP
HP-960FTP industrial pH meter is a high-end pH meter with a four-point alarm and a time sharing proportional control function.It connects pH sensor and measures pH and temperature in the sample water.It can also be linked with a cleaning device via an external input, extending its automatic operation time.Many types of electrodes are available to match the sample properties.
-
product
Resistivity Cell For N1413 With B2980 Series (26/50/76 Mm Diameter Electrodes)
N1424C
The N1424C is designed to operate specifically with the B2985B/87BElectrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424C to the B2985B/87B.
-
product
Spring Clip Fixture
16092A
Use this test fixture with parallel electrodes for impedance evaluation of both lead and SMD components.
-
product
Portable optical DO meter
ARO-PR
The Portable optical DO meter makes use of the fast-response optical DO sensor RINKO, maintaining its high-speed response performance (99% response < 7sec). The meter probe is equipped with a temperature sensor close to the sensing foil, and the measurements are made by simply inserting the probe into a DO sample bottle (the calibration is carried out using the National Metrology Institute of Japan (NMIJ) certified traceable gases standards). Differently from galvanic electrode sensors, the instrument does not require water sample stirring or fixing reagents, since there is no oxygen consumption. Thus, the required time to estimate dissolved oxygen is considerably reduced. The display unit shows the output instantaneously, and you can check the measured values in real time.
-
product
BOMBARDING A.C. MILLIAMPERES METER
A Bombarding A.C. Milliamperes Meter is one of the four instruments essential for proper luminous tube processing. This instrument monitors the level of bombarder current in milliamperes that is generated by the bombarder, through the tube being processed. It is necessary to accurately monitor the current for the tubing and electrode sizes used to ensure that the right amount is applied at the appropriate time. To do otherwise may cause damage to the electrodes, fluorescent coating inside the tube and adversely affect the glass structure.
-
product
Scanning Electro-chemical Microscope
920D
The scanning electrochemical microscope (SECM) was introduced in 19891 as an instrument that could examine chemistry at high resolution near interfaces. By detecting reactions that occur at a small electrode (the tip) as it is scanned in close proximity to a surface, the SECM can be employed to obtain chemical reactivity images of surfaces and quantitative measurements of reaction rates.
-
product
Thermal Abuse Test Chamber
Guangdong Bell Experiment Equipment Co.,Ltd
DGBELL Thermal abuse test chamber protect for short circuit caused by incorrect operation of the operator and battery electrode, battery positive and negative connection, etc
-
product
Dielectric/Conductivity Sensor
Mini-VariconTM
The Mini-Varicon sensor is a thin, flexible dielectric sensor designed for cost-sensitive use with presses, molds, bulk materials or laminates. Patterned on a polyimide substrate, the electrode array is designed to allow a choice of high or low sensitivity, selected by either using the whole sensor or cutting off a portion of the array at a designated line. The Mini-Varicon sensor can be supplied without leads, or with custom-length Teflon-insulated leads attached.