Filter Results By:
Products
Applications
Manufacturers
- LBA Group, Inc
product
RF Inductors
LBA Technology "Blue Line" RF inductors are based on over 30 years of proven international performance. Blue Line inductors are unsurpassed for hi-Q, stability, and low RF losses. These inductors are manufactured from heavy silver plated copper conductors and brass fittings, treated to resist tarnishing. Windings are insulated with melamine or G-1 0 epoxy laminates. These materials are recognized for their exceptional RF qualities, arc resistance, mechanical strength, and low moisture absorption. Supporting frames are engineered to permit maximum access to windings for convenience in adjustment. The metallic frames are separated by insulators to prevent induced current flow.
-
product
Relaying Current Transformer Analyser
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
product
Winding Resistance Meter
TRM 50+
SCOPE introduces 50 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 50 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
product
Three-Phase Transformer Winding Resistance Meters
TWA Advanced Series
TWA Advanced series is the latest DV Power solution for three-phase transformer winding resistance measurement and tap changer analysis. They are capable of testing six transformer windings with a single cable connection, as well as three-phase automatic transformer demagnetization. It has the option of the automated test mode, where the instrument operates the tap changer without operator input (minimizing the risk of human error) and records winding resistance results based on pre-selected stabilization criteria.The unique DVtest method of tap changer analysis enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, together with the measurement of tap changer motor current which detects motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or simultaneously on three phases. It can also be performed together with the winding resistance test in all tap positions.A unique advantage of TWA Advanced instruments is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer connected in a YN configuration. This can significantly speed up the testing– for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.TWA500 is equipped with a large 10.1” graphical touch-screen display, while TWA400 has a 7” graphical touch-screen display. Besides making the interface much more user-friendly compared to older winding ohmmeters, it also enables certain test options that were previously available only with DV-Win software. The most important among them are DVtest, tap changer motor current measurement, “Heat Run” test, test templates, and automatic test mode.
-
product
Motor/Generator Test Equipment
Winding ohmmeters RMO-M series measure winding resistance of inductive test objects such as electrical motors and generators. Motor test or generator test of winding resistance is especially important for early-stage failure detection.RMO-M series instruments generate true DC ripple-free current with automatically regulated measurement and discharge process. Even more, test instruments are portable and enclosed in a metal casing.Applications supported by DV Power motor/generator test equipment include:Winding resistance measurement of generators and electrical motorsResistance measurement of high-current bus bar jointsResistance measurement of cable splicesAll of the above-mentioned measurements are performed with the highest accuracy. The advanced DV-Win PC software enables collecting both numerical and graphical results. These features provide an easier and more efficient analysis. After the test, a DV-Win software generates a test report a single click. Finally, a user can easily customize the report and save it in different formats, such as XLS and PDF.
-
product
Current Transformer Testers
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
product
Chroma Milliohm Meters
Chroma Systems Solutions, Inc.
The Chroma 16502 Milliohm Meter is Chroma’s newest digital Milliohm Meter. 0.001mΩ~1.9999MΩ wide measurement range. DC, Pulsed, and Dry-circuit test current driving modes, enable the Chroma 16502 can be properly used in DC resistance measurement for various inductive components (coil, choke, and transformer winding etc.), cable, metallic contact (connector, relay switch etc.) and conduction materials.
-
product
Microohmmeter
MMR-6700
The MMR-6700 digital meter is designed for measuring low resistances with a stabilised current of up to 200 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6700 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.
-
product
Digital Electrical Network Analyzer
1826 NA
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
product
Megohm Meter
Digital Megohm Meter, model SMG5, is a compact standalone meter designed for checking HVAC compressor insulation. The SMG5 provides a 1000V voltage source, monitors current, and displays the resistance between the test points. Maximum current output is <1mA. It can be used to determine the condition of insulation from winding to ground in a motor, compressor, or transformer. Includes a case, alligator clip lead tip and leads with removable tips.
-
product
Winding Resistance Meter 50Amps, 2 Channels Rack
WR50-12R
Raytech Digital Winding Resistance meter WR50-12R is the enhanced version winding resistance system with a most advanced demagnetizing circuit as a rack version. It is designed for high degree of accuracy for the measurement of very low resistance of any inductive loads.
-
product
Microohmmeter
MMR-6500
The MMR-6500 digital meter is designed for measuring low resistances with a stabilised current of up to 100 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6500 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.
-
product
Transformer Winding Resistance Meters
TWA Standard Series
The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
Automatic Transformer Winding Resistance Meter 25A
ATWRM-25
The Eltel ATWRM-25 with its latest " State of the art" design is an unmatched high performance of winding resistance measurement providing fast measurements, wide continuous test current ranges, high accuracy and is ideally suited for low resistance measurements both in the laboratory and in HV switchyards.
-
product
Current Transformer Tester
HTCT-300
Full-featured, can not only satisfy various CT (eg: protection, measurement and TP category) but also PT type electromagnetic unit for its excitation characteristics (ie voltage current characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio deviation, angle deviation and other test requirements.
-
product
Three-circuit Transformer DC Resistance Tester
HTZZ-S10A / 218
Wuhan Huatian Electric Power Automation Co., Ltd.
Designed to meet the dc resistance test of three-phase winding in large capacity transformer.
-
product
Motor Winding Ohmmeter
RMO-M Series
The motor/generator winding resistance test is used to identify open windings, shorts between two windings, short to grounds, connection mistakes or shorted turns. This non-invasive test of winding resistance helps to pinpoint problems regarding windings in stator or rotor part of an electrical machine. Additionally, motor winding ohmmeter has the capability of performing heat run test which will show a change in windings resistance with an increase of temperature.The RMO-M series is designed as an ideal aid in preventive maintenance of electrical motors and generators. They are powerful (up to 100A of test current), portable (8 kg) and generate DC current which is completely ripple-free. This makes measurement very precise with 0,1% accuracy.Three voltage channels make measurement very easy since it is possible to obtain a value of all three winding resistances in one measurement
-
product
Transformer DC Winding Resistance Tester
HTZZ-50A / 246
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement transformer around the group and large power inductor dc resistance ideal equipment.
-
product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
product
5 A portable digital micro-ohmmeter
MPK-254
The MPK-254 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1 mA up to 5 A.
-
product
Cable Electric Resistance Tester
MR 270 C-A
The MR270C-A is specially designed for electric resistance measurements in cable industry applications and inductive loads (transformers, motors). It is perfectly fit both for measuring the meter resistance in connection with a corresponding resistance measurement holding device or for final acceptance control of power cable reels. In the case of cable reels, which often have a cable length of several kilometers, both the compensation of the inductive component and the ability to perform measurements in the presence of high noise levels are important. This also applies to the winding resistance of transformers and motors.
-
product
AUTOMATIC WINDING TEST SYSTEM
VE9036SU
6 CHANNEL Microprocessor based Automatic Test System for Automobile Coils, Magnetos, Alternator, Motor Winding. Can Test : Impulse Winding Tester (IW), AC/DC HiPot, Insulation Resistance (IR), Inductance (L), DC Resistance (DCR)
-
product
Electrical Measurement Equipment
Portable equipment designed for maintenance and commissioning of substations and power plants. Low resistance micro ohmmeters, digital timers, windings resistance, contact resistance, circuit breaker timing and motion, phase angle and frequency measurements.
-
product
Winding Resistance Meter
TRM 104
TRM104 is a portable winding resistance meter, designed to work in live EHV switchyards. Winding resistance values of large transformers up to 500 MVA and rotating machines are directly displayed. The meter is protected against the back emf offered by large inductive winding. A back-lit 4 line LCD with a user-friendly menu sets up the instrument for the test. Winding resistances and safety messages are also shown on this display. It is possible to measure the resistance of two windings simultaneously.The meter contains a special power source for rapid stabilization of test results.
-
product
Transformer DC Winding Resistance Tester
HTZZ-100A / 248
Wuhan Huatian Electric Power Automation Co., Ltd.
Applicable for transformer to submit the dc resistance testproject around group in pick up and overhaul project.
-
product
UNI-T Series
Weshine Electric Manufacturing Co., Ltd
mainly used to measure the wire resistance of cables, the contact resistance ofswitches, connectors, relays, the resistance of coils, motors, transformer windings, and equipment enclosures, lightning protection belts, ground beams, structures, cabinets, steel bars, Test the connection resistance between metal components of water pipes, windows, guardrails, radiators, assembly lines, etc. It is widely used in telecommunications, electric power, meteorology, computer rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, lightning rods, etc.
-
product
Transformer Winding Resistance Meters
RMO TT Series
The Tap Changer Analyzer & Winding Ohmmeter of the RMO-TT series is designed for winding resistance measurement of inductive objects, and for a tap changer analysis. The RMO-TT series is based on the state of the art technology, using the most advanced switch mode technology available today. The RMO-TT instruments are accurate (0,1%), powerful (up to 100 A) and still portable. The Instruments generate a true DC ripple free current with automatically regulated measurement and discharging circuit. RMO-TT instruments can perform a simple, quick and reliable transformer on-load tap changer condition assessment. This series of instruments enable measurements of a winding resistance in every tap position, current ripple values (percentage of a current drop during a tap change) and transition times during the tap changes. Problems with a connection, contacts, and selector/diverter switch operation (tap change with interruption) can be detected with these measurements.
-
product
Transformer DC Winding Resistance Tester
HTZZ-10A / 235
Wuhan Huatian Electric Power Automation Co., Ltd.
Measurement transformer around the group and large power inductor dc resistance ideal equipment.
-
product
Electrical Measurements Test
The tests are performed to measure and collect data from electrical and electronic parts using various measurement methods including, but not limited, to the following: capacitance, resistance, winding resistance, insulation resistance, magnetic permeability, power input, and quality factor Q.
-
product
Motor Starting & Control Resistors
Motor Starting Resistors are used to reduce the voltage at the motor terminals and also decrease the starting current. Motor Starting Resistors are necessary because the self resistance of a motor armature is very low. When the voltage is first applied, excessive current will flow. For limiting this current, since there will be no resisting back electromotive force (emf),some series resistance can be added to the armature windings.