Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe Wide Current Range Multiplexer Module, Single 12-Channel, 2-Pole
42-514-105
The 40-514-105 (PXI) and 42-514-105 (PXIe) are low density multiplexers in single 12-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
Precision Current Preamplifier
SIM918
Stanford Research Systems, Inc.
The SIM918 Current Preamplifier is ideal in applications in which the input offset voltage must be kept to a minimum. The DC voltage difference between the two inputs (current input and voltage bias) is accurately measured every 2 seconds, and is nulled.
-
product
XRF Systems
OEM Solutions
Amptek offers a complete line of OEM detectors, preamplifiers, digital processors, and power supplies, and can work with you to help develop custom solutions unique to your needs. We provide established and emerging OEM customers a fast track to the market with our modular systems that will meet current needs, while being flexible enough to adapt to your product roadmap. The below options are typical configurations. Please contact us for custom solutions.
-
product
Current Preamplifier
1212
The Model 1212 Current Preamplifier is designed as a low cost, gerenal purpose, benchtop instrument to provide a high performance detection system for small ac and dc currents. The 1212 operates with a virtual ground at its input which mitigates unpredictable high frequency rolloff due to input cables and stray capacitance.
-
product
Programmable Current Preamplifier
99539
The Model 99539 is a modular, multi-channel current preamplifier with parallel, logic level, gain control input. It consists of circuit boards which plug into a 3 1/2" high by 19" wide rack chassis.
-
product
ProBus Probe Adapter for TekProbe-BNC Probes
TPA10
- Allows TekProbe interface level II probes to work with any ProBus-equipped Teledyne LeCroy oscilloscope- Automatic probe detection- Provides all necessary power and offset control to the attached probe- Supports probes up to 4 GHz- Easy firmware updates- Wide variety of probes supported including: Preamplifiers, Current Probes, Single-Ended Active Probes and Differential Active Probes
-
product
Current Preamplifier
1641
The Model 1641 Current Preamplifier is a simple low cost wideband gain block for use with photomultipliers
-
product
Current Preamplifier
1211
The model 1211 Current Preamplifier was designed to provide all of the features required of a modern laboratory preamplifier. It measures cur rents with full scale sensitivity ranging from 10 to 10 amperes.
-
product
Current Sensors
Our current sensors were designed for a simple, customer-specific construction of niobium wire wound magnetometers, gradiometers or preamplifiers for small current or voltage signals.
-
product
Low Noise Current Preamplifier
SR570
Stanford Research Systems, Inc.
The SR570 is a low-noise current preamplifier capable of current gains as large as 1 pA/V. High gain and bandwidth, low noise, and many convenient features make the SR570 ideal for a variety of photonic, low temperature and other measurements.
-
product
Transducers
Is a unit which comprises a preamplifier fed by a constant current ICP and a condenser microphone
-
product
High-Sensitivity Tri-Axial Accelerometer with Built-In Preamplifier
NP-7310
NP-7310 is the accelerometer with built-in preamplifier, and capable of tri–axial directions simultaneous measurement. It is suitable for the low frequency vibration measurement such as ground vibration or floor vibration while operating the machine. NP-7310 can be used with the sensor amplifier unit such as AU-2100, AU-2300 or PS-1300. Also, it is possible to input directly to the analyzer or recorder which the constant current amplifier is built-in such as the FFT Analyzer of DS-2000 series, DS-3000 series, CF-7200A, CF-9000 series or CF-3650/3850 series.
-
product
Power modules
G.R.A.S. Sound & Vibration A/S
It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplification or attenuation to the signal, thus making it possible to fine tune the measurement chain to the signals being measured and the hardware being used.Selectable filters make it possible to exclude unwanted noise from the measurement, e.g. wind induced noise from outdoor measurements.Overload detection makes it possible to validate the measurements and is a useful tool in monitoring setups.When a Power Module with gain is used, you can use longer cables because of the power module's ability to deliver current.A Power module introduces electrical isolation
-
product
Scanner Probe
RFS set
The RFS set consits of three passive near field probes designed for the use in a measurement scanner during the development of E-field and magnetic field. They are designed for frequency ranges of 30 MHz to 3 GHz. The probe heads of the RFS set allow for close measurements needed to correctly localize interference sources on an electronic assembly. They document the whole image of the device under test`s near field. The scanner probes have a sheath current attenuation and are electrically shielded. They are connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance. The measuring signal can be increased with PA 203 or PA 303 preamplifier. On request RFS, LFS and XFS scanner probes can be produced.
-
product
LISN & Voltage Probes
All commercial LISNs include an artificial hand connection and a transient limiter. This adds a 30dB insertion loss. A 30dB pre-amplifier is included which can be connected in the RF output feed to return the insertion loss to 0dB. The Voltage Probe requirement is covered by our PLIP (Power LIne Interference Probe). This fully meets the requirements of CISPR16, but has additional features:*Fully galvanic isolation between input and output (>1kV), for the safety of operator and analyser!*Shrouded safety clips for attachment to the line to be measured.*Filtered frequency response matched to Band A and B.*Current limiting on the output.*Visual indication of high voltage input.
-
product
Sound Level Meter
831-LOWN
Easily make low noise measurements to 6.5 dB A-weighted using the Model 831-LOWN sound level meter paired with the 378A04 low noise microphone and preamplifier. Due to the innovative design of the 378A04 which uses a prepolarized microphone and ICP (constant current) interface, the combination produces a highly portable system that is battery powered and intuitive to use for measuring low noise levels.
-
product
Brute High Current Probe
P4301-2R
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
Brute Hight Current Probes
P4301
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
Alternate 24.00 (680.00) - 96.00 (2722.00) Godzilla High Current Probe
HC375F-6
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
Brute High Current Probe
P4301-2F
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
product
Preamplifiers
Preamplifiers recognize the extremely low amplitude AE signal produced from AE sensors, and convert the signals into amplified and usable forms. As applications and testing conditions vary, project needs may change as well. Physical Acoustics offers an entire line of preamplifiers for a variety of testing requirements. Operating in conjunction with our specialized AE software, preamplifiers also moderate signal size during the data collection process, helping to produce accurate results.
-
product
Microphone Preamplifier
426A11
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
product
Microphone Preamplifier
426B03
Performance: Nominal Microphone Diameter:1/4"Frequency Response: (0.1 dB) (re 1 kHz)5 to 126000 Hz5 to 126000 Hz Frequency Response
-
product
Preamplifiers
Com-Power broadband high gain preamplifiers were designed for electromagnetic interference (EMI) testing and certification. EMC test labs use preamplifiers to improve sensitivity of the test system during EMI radiated emissions measurements. Without a high gain preamplifier, signals picked by the antenna that have amplitudes below the noise floor of the test system cannot be measured. The preamplifier gain has minimum variations for the entire operating frequency range for accurate emissions measurements. The Com-Power preamplifiers were primarily intended for EMC applications. However, it can be used for other applications that require signal amplification.
-
product
Preamplifiers
Is an electronic amplifier that converts a weak electrical signal into an output signal strong enough to be noise-tolerant and strong enough for further processing, or for sending to a power amplifier and a loudspeaker.
-
product
Preamplifier
The UBBV series are external, extremely low-noise broadband preamplifiers that can be mounted to any SPECTRAN spectrum analyzer. They are ideally suited for spectrum analyzers and oscilloscopes as well as antennas of all manufacturers and are supplied with extensive accessories.
-
product
Preamplifiers
LNA Series
Low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity of virtually all spectrum analyzers and other RF measuring instruments. All measuring instruments have a 'noise figure', which is a measure of how good the instrument is at measuring low level signals, the lower this figure, the better, although the lowest signal level will still be governed by the measurement bandwidth. A typical spectrum analyzer may have a noise figure of 20 dB or more, whereas a typical receiver may have a noise figure of 10 dB. The preamplifier has a noise figure of typically 4 dB, significantly enhancing the low level performance of such instruments, enabling signals that were previously masked by noise to be seen.
-
product
Preamplifiers
The primary function of a preamplifier is to extract the signal from the detector without significantly degrading the intrinsic signal-to noise ratio. Three basic types of preamplifiers are available: the current-sensitive preamplifier, the parasitic-capacitance preamplifier, and the charge-sensitive preamplifier. ORTEC manufactures a preamplifier to fit your detector, your application, and your budget.
-
product
NI-9203, 200 kS/s, ±20 mA, 8-Channel C Series Current Input Module
783731-01
200 kS/s, ±20 mA, 8-Channel C Series Current Input Module - The NI‑9203 is intended for high-performance control and monitoring applications. It features programmable input ranges and variable connectivity options. To protect against signal transients, the NI‑9203 … includes a channel‑to‑earth ground double‑isolation barrier (250 Vrms isolation) for safety and noise immunity.
-
product
BJT Voltage Preamplifier
SIM911
Stanford Research Systems, Inc.
The SIM910 and SIM911 are low-noise, programmable preamplifiers which are ideal for a wide range of small signal applications. The primary differences between the two models are their input impedance and input noise.