Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
High Voltage 50 Pin D-Type Connectors
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
product
LED Power Driver ATS
8491
1. DC Electronic Load : Chroma 6310A/6330A Series2. Transducer Unit/Module*1 : Chroma A849101/A849102, A849103, A8491043. Time/Noise Analyzer : Chroma 80611 & 80611N card4. Sytem Controller*2 : Industrial PC5. DC Source: Chroma 62000P Series6. Digital Power Meter : Chroma 66200 Series7. OVP/Short Circuit Tester : Chroma 806128. ON/OFF Controller : Chroma 80613*1 : A849101 transfers UUT output signal to voltage signal, and measure by 84911 LED power driver measurement card (200kHz). The optional 80611N Noise card is required for 20MHz ripplecurrent measurement.*2 : The controller includes both 84911 LED Power Driver measurement card and 84903 control card.- 84911: Measure rms current, dimming current/frequency/duty, timing, power & ripple current (200kHz)- 84903 : Provide BL control signal(DC level, PWM, SM bus), and enable ON/OFF signal.C Source : Chroma 6500/61500/61600 Series
-
product
DC Power Analyzer, Modular, 600 W, 4 Slots
N6705C
The N6705C DC Power Analyzer provides unrivaled productivity gains for sourcing and measuring DC voltage and current into the DUT by integrating up to 4 advanced power supplies with DMM, Scope, Arb, and Data Logger features. The N6705C eliminates the need to gather multiple pieces of equipment and create complex test setups including transducers (such as current probes and shunts) to measure current into your DUT. The DC Power Analyzer also eliminates the need to develop and debug programs to control a collection of instruments and take useful measurements because all functions and measurements are available at the front panel. For even greater control and analysis functions, the DC Power Analyzer can be used with the 14585A Control and Analysis Software. When automated bench setups are required, the N6705C is fully programmable over GPIB, USB, LAN and is LXI Compliant. 14585A Control and Analysis Software
-
product
Automatic Relay Test Set
DRTS 33
DRTS 33 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 3 Current and 3 Voltage generators simultaneously available.
-
product
In-cylinder Linear Position Transducers
Our In-cylinder Linear Position Transducers are well suited to hydraulic and pneumatic applications. Many of our In-cylinder Linear Position Transducer have features including; touchless magnetostrictive measuring process, unlimited mechanical life, absolute output voltage or current and many more. See our range of products below, click on the links for more information and data sheets.
-
product
4-20mA Bridge AmplifierR
90416
This miniature, on-board, transducer amplifier is capable of supplying excitation voltage and amplifying millivolt signals from strain gage based transducers.
-
product
Automatic Relay Test Set
DRTS 66
DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available.
-
product
AC Voltage and Frequency Transducers
NMTU/F
The NMTU/F device is an AC voltage and frequency transducer with two independent analogous outputs. The A output measures AC voltage, the B output measures the frequency of input voltage. That´s why one single NMTU/F transducer is able to replace two customary transducers, thus making it possible to achieve significant savings in installation space.
-
product
NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783311-01
±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.
-
product
Electrical Power Transducers
Manufactured for utilities since 1969, TransData Power Transducers are used for measuring AC and DC power variables in Substation, Generation, Load Control and Industrial applications where ±1ma or 4-20mA analog signal are required by the SCADA/Energy Management System. Models are available for measuring Current, AC Voltage, DC Battery Voltage, Watts, VARs, Frequency and more.
-
product
Electro Magnetic Flow Meter With Remote Display
MFI-013
Aarohi Embedded Systems Pvt. Ltd
MFI-013 electromagnetic flow meter is manufactured with state of the art technology. Micro controller based design provide precise measurement. A magnetic flow meter (mag meter, electromagnetic flow meter) is a transducer that measures fluid flow by the voltage induced across the liquid by its flow through a magnetic field.The physical principle at work is electromagnetic induction.
-
product
PXIe-4339, 25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module
783531-01
25 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4339 is a universal bridge input module ideal for test cell installations requiring both accuracy and flexibility. Completely configurable through software, each channel can take bridge-based measurements and direct voltage measurements. Eight input ranges in ratiometric mode and four in voltage mode accommodate a wide variety of sensor types for your changing application needs. The PXIe‑4339 also features per-channel wide bandwidth analog outputs, programmable excitation, Transducer Electronic Data Sheet (TEDS) support, and digital filtering.
-
product
ChenYang Voltage Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
DC voltage sensor/transducer works according to Linear PhotoelectricalIsolation and is designed for applications to measurement and monitoring of DC voltage. Theoutput signal (DC voltage or current) of this transducer is proportional to the input DC voltage.They are suitable for measurements and long time monitoring of DC voltages and can applied topower supply management, DC motor drivers, battery chargers and systems etc.
-
product
Displacement Transducers - DC Operation
Columbia Research Laboratories
The Columbia DDCP Series Transducers are completely self-contained displacement measurement systems that operate from a low voltage DC power supply or battery. They permit highly accurate readout and recording of an output signal directly without auxiliary signal conditioning electronics.
-
product
NanoVIP® TWO™ PLUS
NanoVIP® TWO PLUS™ is a modern, compact and powerful portable Power Quality analyzer for professional use; it can be used on single-phase, two-phase, three-phase balanced networks, low and medium voltage as well as on chillers and pumping system to monitor all performance parameters.In addition to its electrical channels, it has 4 sensor channels to read whichever type of transducer: 4..20mA, 0..1V or PT to monitor and store data of whichever system.Thanks to the MRH™ hardware onboard, it can be connected to a QUADRA measuring network as a DGP device.A long lasting battery and the huge logging capability of data (over 1 year) are distinguishing characteristics that make it an absolute reliable and unique professional tool.
-
product
Analog Output Data Acquisition (DAQ) Products
Analog Output boards are useful when you need an output where the condition is not just an on or off state. Analog Output boards convert digital values generated by software into the analog voltage or current signals required for controlling frequency inverters, valves, sliders, brightness of lights, or things controlled by motors and other mechnical transducers.
-
product
3-Phase AC Voltage Transducer
ENVIROMUX-PT3-600
Monitors and reports voltage of any 3 phase circuit. Remotely detect blown fuses or tripped circuit breakers. Three 600 VAC inputs, three 4-20 mA outputs. Inputs and outputs isolated from one another. Frequency: 50/60Hz. Maximum primary current: 600 volts. Accuracy: ±0.25% F.S. @60Hz. Output: 4-20 mA. "Zero" adjustment for accurate 0 VAC reading, and "Calibration" adjustment for frequency and voltage level. Powered by the ENVIROMUX-S420MA-24V. Regulatory approvals: UL, CUL, CE. Requires two ENVIROMUX-S420MA-24V to monitor three phases. Caution: installation should be performed by qualified electricians only. Make sure electrical service is disconnected before making any electrical connections.
-
product
48-Channel High Performance Strain Gauge Measurement Instrument
EX1629
48-Channel High Performance Strain Gauge Measurement InstrumentSupports quarter-bridge (120, 350Ω or user defined), half-bridge or full-bridge24-bit ADCs, sampling rates up to 25 kSa/sBuilt in programmable differential excitation -8V to 8VBuilt in selectable bridge completionConfigure signal conditioning excitation and bridge completion on a per channel basisSimple, low-cost wiring using RJ-45 telecom connectorsSupports TEDS for easy transducer detection and setupRJ-45 input connector reduces setup cost and timeBuilt in self-calibration and shunt calibrationSupports voltage, ratiometric and linear measurements other than strain measurements.
-
product
ADC DAC Module
ZET 210
ZET 210 ADC DAC module is used for constant and alternating voltage signals digital processing and parameters control (the signals are retrieved from various primary transducers). Digital and analog outputs can be used within the scope of actuating units control systems.
-
product
Analog Input Products
Analog input boards are useful for measuring variably changing conditions in the real world. When we want to measure these variably changing conditions, we need analog inputs to convert these changing real world conditions to changing electrical quantities. For example, monitoring the temperature inside a wood kiln, or the water pressure on the output of a pump, or the heart rate of a medical patient. In each of these cases, you can use one of our analog input devices to convert the electrical data from a sensor or transducer into binary data that can then be used by your computer. The device that converts this data is known as an analog to digital converter (abbreviated ADC, A/D, or A to D). An analog input is a measurable electrical signal with a defined range. The analog input changes continuously in a definable manner in relation to the measured property. This data is very useful for process monitoring, process control, or simple monitoring / data collection and acquisition. ACCES' analog input boards amplify and multiplex input signals from thermocouples, strain gauges, accelerometers, photo sensors, flowmeters, RTDs, thermistors, voltage sources, millivolt sources, and current sources, just to name a few.
-
product
Complete Field Meter Site Testing Solution
7 Series
We raised the industry standard by introducing the PowerMaster 7 Series as a true 3-phase analyzing reference standard with internal 3-phase current and voltage source capability. The innovative design of the PowerMaster® 7 Series allows utilities to fully test a metering installation with one piece of equipment. Customer load meter testing, phantom load meter testing, CT burden and ratio testing, CT de-magnetization, PT ratio testing, and transducer testing can all be performed with one solution. In addition, vector diagrams, voltage and current waveforms, and harmonics data up to the 100th harmonic can all be analyzed to complete a true wiring verification.
-
product
Intelligent A/D I/O Unit
RAD242
Model RAD242 is an intelligent, two-differential-channel, 24-bit analog-input interface unit that includes a Delta-Sigma A/D converter. The converter has a digital output filter with adjustable notch frequency from 10 Hz to 2000 Hz. The pod also has 13 bits of digital input/output. A precision 10 VDC voltage that can be used for transducer excitation is available at connector pin 5. As much as 60 mA current can be provided. It is packaged in a NEMA 4 enclosure for remote installation in harsh environments. RAD242 also provides a user-definable interrupt input and counter/timer input. An optional RAD Firmware Development Kit is available if you wish to use those user-programmable input lines or to develop a custom program.
-
product
Circuit Breaker Analyzers & Timers
CAT Advanced Series
DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.
-
product
Digital Insulation Tester
DIT-1020
Laxtronics Instruments & Controls Pvt. Ltd
Digital insulation tester Model No: DIT-1020 is designed to carry out electrical insulation measurement in delicate or sensitive electronic sensors, transducers, modules and assemblies with test voltage of 100 Volts DC, its short circuit current is less than 500uA.
-
product
TE-Metrology
HIGHVOLT Prüftechnik Dresden GmbH
The TE measurement complements the high voltage test and is part of the routine and type testing of numerous electrical devices. It is one of the most important non-destructive methods for detecting faults in electrical installations. The breakdown of an insulating material usually occurs at an internal weak point, which usually already shows a partial discharge activity in advance. For this reason, measuring partial discharges can help prevent costly damage. The TE measurement is thus used for quality testing and diagnosis in the factory as well as during on-site testing of cables, GIS, power transformers and transducers or rotating machinery and their components
-
product
AC and DC Current or Voltage Transducers
VT7 AND VT8 Series
The Model VT7 Series dc voltage transducer produces an output which is directly proportional to the input from dc to 10kHz. It functions as a millivolt dc shunt or a high voltage isolator to 1000V
-
product
Plug-in Test Systems
FAME is the innovative, modular plug-in test system for measuring and testing tasks in protection technology for medium-voltage and high-voltage switchgear. The plug-in test system combines complex switching operations for testing the function of current transformers and voltage transducers, as well as tripping and signal contacts.
-
product
Process Voltage & Current Data Loggers
Monitor and log virtually any process voltage or current output from your transducers.
-
product
Test Equipment for Instrument Transformer
is desirable for measuring ratio errors and phase angles of low current (voltage) transformers used in electric devices, such as watt hour meters, smart meters, digital current meters, and transducers, etc.
-
product
Load Monitoring Units (LMUs)
Magtrol's Load Monitoring Units are used for measuring load, force and weight from signals generated by strain gauge transducers. Specifically designed for use with Magtrol's Load Measuring Pins and Load-Force-Weight Sensors, the LMU Series provides excitation voltage while conditioning the bridge output signal. Each unit contains DIP-switches and jumpers for greater flexibility and complete adaptability
-
product
PXIe-4480, 1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module
784277-01
1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module—The PXIe‑4480 is designed for high-bandwidth audio, acoustic, and vibration measurements. It provides six channels of dynamic signal acquisition, and you can use one of four gain settings to configure your input range. The PXIe‑4480 also includes software-configurable AC/DC coupling, charge measurement, voltage excitation, IEPE excitation, and TEDS support, making it ideal for measuring acoustic transducers, pressure sensors, and hydrophones. Common applications include audio test; noise, vibration, and harshness (NVH) analysis; and underwater acoustic measurements. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4480 can sample up to 20 MS/s per channel in time-domain mode.