Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
Standard Voltage 37 Pin D-Type Connectors for Pickering
The connectors below are suitable to use with Pickering cards and modules that utilize a standard voltage 37-pin D-type connector.
-
product
Force Tensiometers
Sigma 702ET
The Sigma 702ET Transformer Oil Analyzer has been specifically designed to guide the user through the measurement of interfacial tension of transformer oil according to relevant standards.
-
product
LVDT Sensor Amplifiers
Analog Devices signal conditioning ICs, together with linear variable differential transformers (LVDTs), can be used to convert mechanical position to a dc voltage. The IC provides both the excitation for the LVDT and the output conversion to dc level with a user selectable gain. ADI LVDT signal conditioners are available to interface with a wide range of LVDTs, including half bridge and standard 4- and 5-wire.
-
product
ANSI Relaying Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
CT & PT Test Kit
PCT200i
PCT200i is specially designed for current transformer characteristic test.This CT analyzer can finish the measurement class CT and TYP class CT.The additional functions include ratio and angle differential tests (the measurement points in the GB standard),FS and inductance,steady-state parameters,peak error and transient parameters,etc.
-
product
Embedded Synchro - Resolver -
LVDT I/O Cards
Computer Conversions Corporation
100% Transformer Isolation is offered for all AC I/O, and various Isolated DC converters are available as standard product, eliminating concerns for ground-loops, ground interjected (intermittent and ghostly) field noise, inductive surges, differing potentials, and high voltage field transients from effecting the card itself, the sensitive ISA bus backplane and any other device or system sharing these signals.
-
product
Terahertz (THz) Lasers From 0.89 To 2.52 THz
Insight Product Company offers terahertz lasers at frequencies from 0.89 to 2.52 THz. Output power is from 1 mW to 15 mW. Diameter of the output wave beam is ~ 40 mm. Typical sizes is 1.2x0.3x0.4 m. Transformer from quasi-optical output to the standard wave guides can be provided. The energy pumping is provided either by DC discharge or HF discharge.
-
product
Aging and Life Test Rack
SY2036
SY2036 Aging and life test rack is fully designed according to the IEC standard, and can also be designed based on the customer request. SY2036 can test LED, CFL, HID Indoor lamp and Outdoor lamp. Input Power supply: AC220V, 50/60HZ, 12KVA Min (110V is option) • Built-in transformer: 0-250V 5KVA and 0-300V 5KVA (Other power is option) • Maximum power for EUT: 5KVA and 12A (Other power is option) • EUT and Number: 112pcs B22, 112pcs E27. 36pcs T5/T8/T12 Tube. 32pcs LED panel (Other EUT can be designed according to customer request) • ON/OFF test: Can be set on the touch screen with program • Test number: 0~99999(Adjustable)
-
product
RF Transformers
Pulse continues to lead the way with a broad range of components that enable twisted-pair copper high-speed services to homes and businesses. Pulse components are also used in cable modems and the consumer electronics that provide home networking services. Our high-performance transformers support home phone line and power line networks. These transformers are designed to exceed ANSI and ETSI standards, and have excellent THD performance and small footprints.
-
product
Isolation Transformers 230V
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
product
Fiber Optic Temperature Sensor with the EasyDisk
The TPT-62
The TPT-62 fiber-optic temperature probe family employs industry standard 62.5µm core OM1 fiber optic for highly improved optical, mechanical, and reliability properties over legacy 200 µm core (1st generation) fiber optic sensors. The EasyDisk sensor tip assembly ensures IEC60076-2 (Annex E) compliant installation and enables quick insertion of the probes into the spacers within the windings of transformers.
-
product
Transformer Variable Radio Tester
WABC
Wuhan Sangao Electrical Test Installations Limit Co.
Acc to IEC and Relevant national standard, In the power transformer production, transfer and user test process, Transformer ratio test is necessary project, This can be used for quality supervision of transformer factory and the use process, prevent the transformer winding inter turn short circuit, open circuit, connection error, pressure regulating switch failure or contact fault.So our company development and production of automatic ratio tester in the original basis according to the user's site using requirements , make the operation more convenient, complete function, stable and reliable data, the testing speed is greatly improved.To meet the needs of all kinds of small medium and large transformer ratio test.
-
product
Differential Transformer Type Extensometers
DT Series
ISO Class 1 Compliant Differential Transformer Type Extensometers The ISO 6892-1 standard for tensile testing of metallic materials prescribes Class 1 or higher extensometers, and JIS Z2241 prescribes Class 2 or higher extensometers when measuring withstanding pressure. The DT series includes Class 1 compliant differential transformer type extensometers, which can be used to implement test methods compliant with metal tensile test standards.
-
product
ANSI Standard Burden Sets
Voltage and Current
Testing and calibrating instrument transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. The burden sets described below have been carefully designed to meet these requirements.
-
product
Oil Test Set
RR-OIL TEST SET also known as OIL BDV KIT is an equipment-designed and produced to test the ELECTRICAL STREGTH of Liquid Insulating Materials such as Transformer Oil, Capacitor Oil etc. The test set carries out test on these materials as per Indian Standard Specification IS 6792. This Oil Test Set is essential for Transformer & Switchgear Manufacturers, also for oil filtration units.
-
product
Meter Testing System
ASTel
Three-phase Meter Test Equipment of ASTeL 3.2x.x series system is a fully automatic system enabling simultaneous, multi-position calibration and legalization of electric energy meters. The automatics include power sources, reference standards, stand controllers, photoelectric scanning heads, separating transformers, and other elements of the system. All these elements are controlled through a Windows based executive program.
-
product
8-Gas On-Line Transformer Gas Analyser
TRANSFIX
The TRANSFIX is an 8-gas on-line transformer DGA monitoring unit. Using specially developed advanced photo-acoustic detection technology, the TRANSFIX measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm). The measurement of these gases allows the user to detect and diagnose a complete range of transformer faults.
-
product
Autotransformer
T-1007
The Titan Series T-1007 Auto-transformer is used to conveniently scale the standard OV to 130V / 260V full scale Titan AC Power Source/Frequency Converter output to either X .5 stepdown (OV to 65V) or X2 stepup (OV to 520V). It has a 1.2 KVA power rating with excellent bandwidth and voltage regulation.The unit is of toroidal design, making it approximately half the size and weight of a comparable stacked laminate transformer. It is center filled with epoxy for isolation and durability, and features simple 1/4" bolt center mounting.
-
product
Flash Point Tester
Weshine Electric Manufacturing Co., Ltd
Closed flash point tester, when the test sample is used in a closed environment (such as transformer oil), to determine the closed flash point value of petroleum products. Use touch screen instead of keyboard operation, adopt foreign advanced technology, large LCD screen LCD full Chinese display man-machine dialogue interface, full screen touch key prompt input, convenient and fast, open, fuzzy control integrated software, modular structure, in line with national standards, the United States, EU and other standards.
-
product
Transformer Turns Ratio Meter
We are considered as one of the leading manufacturers and exporters of Transformer Turns Ratio Meter With/ Without Phase. The equipment is widely used in power generation and engineering industry for testing of transformers. We engineer and develop this testing equipment in accordance with industry standards using best grade components and raw materials. This Transformer Turns Ratio Meter With/ Without Phase can be also optimized according to client's specific requirement. We offer this testing equipment at competitive price.
-
product
VOLTAGE TRANSFORMERS
Designing & manufacturing a range of high quality, voltage transformers in three different frame sizes for both measuring and protection duties. Transformers which are designed to comply with the requirements of IEC 61869-3 or other international standards as required can be supplied to satisfy most Low Voltage applications.
-
product
Standard Current Transformer
HL / 640
Wuhan Huatian Electric Power Automation Co., Ltd.
It is used as the calibration standard of current transformer in the error test of transformer.
-
product
Environmental Test Probe, Temperature
72-8364
Type K Surface Temperature Probe Surface probe is ideal for flat stationary surfaces such as molds, heating elements, integrated circuits, transistors and transformers. Very low sensor element mass enables fast response measurement time. Type K thermocouple temperature probes are commonly used with all types of industrial temperature controls and measurement equipment, and are compatible with Tenma handheld thermometers and digital multimeters that include temperature function. All are terminated with standard Type K plugs. See the complete line of Tenma Thermocouple Probes and Accessories
-
product
Turns Ratio Testers
TRT Standard Series
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
product
IEEE 1394b/AS5643 Mil1394 (FireWire), Triple-Node Multi-Port, Communications
FW3
The FW3 function module provides IEEE 1394b/AS5643 (Mil1394) support on each of its three nodes, which are configured as 2 nodes with 3-ports and 1 node with 2-ports. AS5643 defined flight ready robustness and active transformer isolation to enable longer cable lengths (20 meter) between nodes. Together these standards provide the deterministic and redundant communications protocol required for Vehicle System (Flight Control) Networks. The FW3 multiple ports per node configuration allows the user to create tree, daisy-chain and looped topologies needed to optimize cable length and weight while creating redundancy.
-
product
High Voltage Impulse Test Set Up
We are renowned as the foremost manufacturer and exporter of High Voltage Impulse Test Set Up. This testing equipment is demanded in electrical, power generation and engineering sector. It is incorporated with fiber optic isolated digitizers to test various types of transformers. We utilize excellent grade raw materials to engineer and develop this High Voltage Impulse Test Set Up in accordance with industry standards. Our clients can get this equipment from us at competitive price.
-
product
Current Transformers
A range of ring type current transformers suitable for primary currents from 1A-5000A with 1A or 5A secondaries. This standard range of measuring and protective current transformers is available as resin coated or tape wrapped.
-
product
Voltage Transformer Testing System
KVTS
The Knopp Voltage Transformer Testing System is designed to measure the accuracy of instrument transformers having 120 volt secondaries and up to 14,400 volt primaries (special order for up to 36,000 volt primaries is available). The system includes a control console which contains the control circuitry, ANSI standard burdens, and the Knopp Automatic Transformer Comparator. The Knopp precision and loading transformer set is also included (as pictured) and is connected to the console via a special cable.
-
product
Isolation Transformers 230V
PeakTech Prüf- und Messtechnik GmbH
Due to the high safety requirements in service workshops, schools and industry, an isolating transformer is an absolute prerequisite for carrying out professional repair work. Galvanic isolation between primary and secondary voltage during measurements and repairs on open devices guarantees a high safety standard for the user. Of course, galvanic isolation from the mains voltage also offers other advantages in electronics development, audio technology and many other areas.
-
product
ANSI Metering Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
Instrument Transformer
Our company has achieved a reputed niche in international market by manufacturing and exporting a great range of Instrument Transformer. Widely used in electrical, power generation and engineering sector for transforming voltage or current level, this equipment is in accordance with industry standards. Manufactured using excellent grade raw materials sourced from reputed vendor, Instrument Transformer is offered to clients in different technical specifications. We stringently test this instrument on varied standard parameters.