Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe Analog Output/Current Loop Simulator Module - 12 Channel
43-765-002
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Multifunction Electrical Installations Meter
MPI-525
Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.
-
product
PAT and Installation Verification Unit
PowerCheck 1557
The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.
-
product
Multifunction Electrical Installations Meter
MPI-520S
The MPI-520S multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520S is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.
-
product
PXI Analog Output/Current Loop Simulator Module - 8 Channel
41-765-003
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Anti-Tamper Sub-Assemby (DC Immune CTs + Potential Transformer)
Shanghai Powoo Industry Develop Group Limited
ATS can provide double loop current sampling and power supply for measuring unit of static meter. When load voltage, static meter can in normal condition without single-channel current.
-
product
HART Protocol Stack
softHART
SoftHART is the industry-standard smart HART (Highway Addressable Remote Transducer Protocol) communications stack for industrial automation. HART is a bidirectional protocol and communicates over existing 4-20 mA analog current loops, extending communication capabilities without the inconvenience of installing additional wiring.
-
product
Single Channel Potentiostats
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
product
PXI Analog Output/Current Loop Simulator Module - 16 Channel
41-765-001
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Intelligent Transmitter with Digital Indication
LEO 3
KELLER AG für Druckmesstechnik
LEO 3 is a micro-processor based transmitter with digital double-display for pressure (top display) and for the output signal (bottom display). The display is powered from the 4...20 mA current loop. Functions:
-
product
100 Ampere Micro OHM Meters
Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester, and uses a test current of 100A DC, resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new, fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100
-
product
Loop Resistance Measuring Device According to DIN EN 61557-3 (VDE 0413-3)
PeakTech Prüf- und Messtechnik GmbH
A loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
product
Multifunctional testers
MI 3152 EurotestXC
MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests.
-
product
Closed Loop Hall AC/DC Current Sensor
CYHCS-D8
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current in the carrying conductor.
-
product
Analog & Digital I/O Modules
USB analog and digital I/O modules are a complete family of data acquisition modules for use in process control systems. The analog input modules can measure process signals such as DC voltage, thermocouples, 4-20mA current loops, discrete contact closures.
-
product
Three Axis Helmholtz Coil Systems
Macintyre Electronic Design Associa
he MEDA turnkey closed loop magnetic field sources cancel the local ambient field as well as generate accurate and uniform magnetic fields in a control volume. The sources use Helmholtz coils driven by control currents to produce stable magnetic fields from 1 nT to 100,000 nT. The accuracy of the field in the control volume is better than 0.05% of the setting.
-
product
Current Loop Calibrator
LC-100
The Current Loop Calibrator an accuracy of 0.015% and a 0.001 mA resolution. The loop calibrator can simulate, power, and measure two-wire transmitters. With automatic Step and Ramp functions, the precision loop calibrator also enables remote calibration of 4-20mA devices.
-
product
Calibrator Process
VA70034
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Loop calibrator This Calibrator is use to measure or output 0 to 24 mA DC current loop, and 0 to 20 V DC voltage.
-
product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
product
Precision Current Loop Calibrator With Hart Communications
LC-110H
The Martel LC-110 and LC-110H are mA (loop) calibrators designed to take the loop calibrator class to the next level. The new LC-110 series feature a user friendly interface with dedicated buttons and a rotary encoder (Quick-Set Knob). This combination drastically reduces the time it takes to measure, simulate, or source both voltage and current and power up a loop. The rugged ABS plastic case is contoured to easily fit a technician's hand and the large back lit graphics LCD is best in class. The LC-110H differs from the standard LC-110 in that it incorporates HART communications and supports a select set of the HART universal and common practice commands. This unique feature allows the LC-110H to be used as both a loop calibrator and communication tool.
-
product
Microwave Moisture Meter
RX-95
The system works based on the absorption of microwave energy by water molecules contained inthe x-rayed material. It is a non-contact, non-destructive method of instant measurement of water content - used for materials such as coal, flour, grain, cement, seeds, sugar, etc. Thanks to high measurement sensitivity (resolution greater than 0.01% of water content by weight), short measurement time (about 5 times/sec.) and repeatability of measurement - the system is suitable for continuous measurement of material moisture, e.g. on conveyor belts and its recording on a PC or using a 4-20 mA current loop.
-
product
Current Loop Adapter
OP-1C
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
Dual High Speed Power Supply
VX4620
Dual high speed power supplyLow noise linear output stage with 200 Vpp and 1 AProgrammable bipolar voltage and positive/negative current limitsStable control loop even on long load linesAuto sensing featureProgrammable slew rateProgrammable over GPIB, USB or RS232Fast rise and fall times due to integrated sink capability
-
product
Measurement & Simulation
Highland Technology offers a wide array of tools for measurement, simulation, and control. Tachometers, thermocouples, RTDs, precision voltages, current loops, strain gauges, and more can be measured or simulated by Highland's products.
-
product
PCI Express 16 Reed Relay Output
8004He
The 8004He PCI Express digital I/O interface provides 16 optically isolated inputs and 16 Reed relay outputs. The isolated inputs protect the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments. The outputs provide high quality, long-life, dry contact switch closures suitable for low-current applications.
-
product
NI-9265, 4-Channel C Series Current Output Module
779334-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
Current Loop 20 MA Constant Current SI-module With Optical Isolation
MXTTY
Current loop 20 mA constant current (active, passive) SI-module with optical isolation.
-
product
Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
product
Multi Function Testers
Kyoritsu Electrical Instruments Works, Ltd.
Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs
-
product
PXI Analog Output / Current Loop Simulators
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
product
DC current Sensors
CTH
The CTH sensors convert dc current to an isolated voltage output, the CTHR sensors convert ac current to a dc output signal proportional to the Arms. All popular process control voltage and current loop outputs are available. Through hole or split core options mean that connection is non-intrusive and straightforward. The available input range of the CTH sensors is any value from 5A to 6000Adc.