Filter Results By:
Products
Applications
Manufacturers
- Taylor Dynamometer, Inc.
product
Eddy Current Engine Dynamometers
A precise, low-maintenance, rapid response and repeatable alternative to water brake technology, Taylor’s Eddy Current Engine Dynos provide low-inertia, air- or water-cooled operation for testing engines up to 966 hp (720 kW) in a range of markets.
-
product
Fibre Channel PXI Express Test & Simulation Instrument
PXIe-FC4
Avionics Interface Technologies
3U PXIe form factor will fit into any PXIe or hybrid slot - Supports Point-to-Point, Switched Fabric, and Arbitrated Loop topologies - Two independent Fibre Channel ports - Two SFP sockets accept fiber or copper transceivers - Each port supports 1, 2, and 4 Gbps speeds - Comprehensive decoding of FC-1, FC-2, and Upper Layer Protocol (ULP) frames - Triggering and Filtering - Error Injection on any Header or Payload Parameter - Data Capture to on-board memory or disk file - Live Capture and Current Value Monitoring - IRIG-B Time Code Encoder/Decoder for Data Correlation - In-line Port Configuration for Transparent Analyzer - Supports multiple ULPs including FC-AE-ASM, FC-AE-RDMA, FC-AE-1553, and FC-AV - Supports HS-1760E applications, including AS5653, AS5625, and AS5627fcXplorer Windows-based FC Simulator and Analyzer Test Software
-
product
Single Port Serial Interface
APCI-7300-3
*PCI interface to the 32-bit data bus. *Asynchronous communication adapter, 1-port serial interface*1 socket for SI modules*Modular structure through SI modules*Configurable as: RS232, RS422, RS485, with or without isolation, or 20 mA Current Loop (active, passive) with isolation*Addressing through software
-
product
Remote Indicators
ABB field indicators provide a convenient way to access the field instruments data when they are located in remote or difficult to access areas. Powered directly from the 4-20 mA current loop, they require minimal effort to setup.
-
product
ThePoint - Loop Powered Level Switch
ThePoint Loop Powered two wire level switch provides a current output and has hazardous area approvals making it a good choice for most of your point level application requirements. ThePoint level sensing device offering is suitable for most temperature, pressure, and material types.
-
product
PXI Analog Output/Current Loop Simulator Module - 8 Channel
41-765-003
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Open Loop Current Sensor
C03 30A
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
product
Fuse Buddy Current Loop
307M/308B
*Just clamp your current probe over the loop to access the amperage draw through a fused circuit. *Easy testing access, plugs right into fuse socket, no more hand made adapters. *Testing range 0-30 Amps - Do Not Exceed 30 Amps
-
product
180V-260V AC Socket Tester With RCD Test (For UK)
1943
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 180~260VAC circuit.*LED indicators & Digital display.*30mA leakage current measurement.*RCD Test.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 11W*Frequency: 50Hz
-
product
Battery Charge And Discharge Test System
9841
*Easy user interface*Measure Voltage, Current, Power, KWH, AH, Temperature, Reference Voltage*Accuracy Measure Time*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery. *The test result will be stored to ACCESS data
-
product
NI-9265, 4-Channel C Series Current Output Module
779334-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
Digital Electrical Network Analyzer
1826 NA
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
product
Multifunction Electrical Installations Meter
MPI-520S
The MPI-520S multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520S is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.
-
product
Multifunction Installation Testers
Shanghai Beha Electronics Co., Ltd.
Loop impedance and prospective short circuit current measurement• Line impedance and prospective short circuit current measurement• Earth loop resistance in TT-systems• Rotary field test• RCD measurements (contact voltage, trip time, trip current - ramp method)• RCD analysis for test of all RCD parameters • Low Ohm and continuity measurement • Insulation measurement up to 1000V (suitable for 690 V industrial mains systems)• Earth resistance measurement with probes and clamp adapters• Voltage and frequency measurement • Current measurement with clamp adapters(optional)• Power and energy measurements• Harmonics measurement for voltage and current upto the 21st harmonics
-
product
Alarms
Devar alarms are designed to accurately monitor process trip-points from current, millivolt, DC volts and thermocouple signals. These alarm points can be easily set in percent of signal or directly in engineering units. The units will constantly monitor the set point against the actual signal and switch a 10 amp SPDT relay when the set point is exceeded. Alarms are available in wall mount, panel mount, track or DIN rail mount, AC/DC line voltage powered or loop powered versions.
-
product
PCI Express 8 Reed Relay Output
8012eS
The 8012eS PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.
-
product
Loop Calibrator
MS-420
The Loop Calibrator is a multi-purpose process loop tool that offers high accuracy in an ultra-small, rugged package. A single pushbutton selects one of five current outputs (4, 8, 12, 16 or 20 mA), which can drive up to 300 Ohms, or can act as a 2-wire simulator with an external loop power supply of up to 30 VDC.
-
product
Multifunctional testers
MI 3152 EurotestXC
MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests.
-
product
Quad Ammeter
4014
Red Phase Instruments Australia Pty Ltd.
The Model 4014 integrates four ammeters for the direct and simultaneous reading of C.T. secondaries up to 10A during the setting up or checking of protection systems while they are in service with normal 50/60Hz primary currents flowing. The two terminals of each channel of the Model 4014 are connected in series with the C.T. secondary with all other equipment in the loop or directly across the C.T. secondary.
-
product
PXI Analog Output / Current Loop Simulators
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
product
Toxic Gas Sensor
Model 100
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
product
Single Channel Transmitter
1066
The model 1066 Single Channel Transmitter is a loop powered device that can accept input from pH/ORP, conductivity (contacting and toroidal), and amperometric (dissolved oxygen, chlorine, and ozone) sensors.The model 1066 Single Channel Transmitter can display a liquid analytical measurement, in addition to a temperature measurement, current output, and diagnostic information. The transmitter has quick start programming for shorter installation times and an intuitive user interface for easy operation.
-
product
Current Converter AC
NMTI 2
A modern multipurpose quantity-to-current loop converter designed for installation in switchboards.
-
product
Contact Resistance Tester
Weshine Electric Manufacturing Co., Ltd
The loop resistance tester is used to test the conductive loop resistance of various switchgear, and the test current shall not be less than 100A. Due to the oxidation of the contact surface, poor contact tightening and other reasons, the contact resistance increases. When a large current flows, the temperature of the contact point increases, which further accelerates the oxidation of the contact surface and further increases the contact resistance.
-
product
Insolator
The USB isolators effect a potential decoupling of all USB connections and separate the 'normal' PC system from the critical application. They are the professional tools to avoid and fight ground loops and equalizing currents and to protect against overvoltage.
-
product
4-20mA Current Loop USB Data Logger
EL-USB-4
This data logger measures and stores up to 32,000 current loop readings over flashing red and green LEDs. The data logger features a pair of screw terminals and is supplied complete with a a 4-20mA d.c. measurement range. The user can easily set up the logging rate and start time, and download the stored data by plugging the module straight into a PCs USB port and running the purpose designed software under Windows 2000, XP or Vista
-
product
Loop Resistance Measuring Device According to DIN EN 61557-3 (VDE 0413-3)
PeakTech Prüf- und Messtechnik GmbH
A loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
product
Loop Testing
Megger loop testers offer both traditional measuring techniques and state of the art “non-RCD Tripping” technology. Use these products to determine the prospective earth fault current, which is the maximum current able to flow in a phase-earth fault in an installation, and also to indicate the prospective short circuit current which is the maximum current able to flow in the event of a phase-neutral fault.
-
product
Dual High Speed Power Supply
VX4620
Dual high speed power supplyLow noise linear output stage with 200 Vpp and 1 AProgrammable bipolar voltage and positive/negative current limitsStable control loop even on long load linesAuto sensing featureProgrammable slew rateProgrammable over GPIB, USB or RS232Fast rise and fall times due to integrated sink capability
-
product
NI-9265, 4-Channel C Series Current Output Module
779334-02
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
High Current Transformers
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.