Filter Results By:
Products
Applications
Manufacturers
Shunts
An Instrument Shunt is a resistor connected in parallel with a measuring device to move the current range beyond a particular value for which the instrument is capable of measuring directly.
See Also: Current Shunts
- Valhalla Scientific Inc.
product
Multiphase Power Analyzer
2800 Series
The Valhalla Scientific 2800 High-Precision Power Analyzer is available in 1-, 2-, 3-, 4-, 5-, or 6-phase versions. All voltage inputs 0.3V up to 1500V peak and all current inputs 1.5mA up to 1A; 15mA up to 5A; 1A up to 40A; and shunt inputs 60mV up to 6V are potentially free and exhibit low noise, high common mode suppression, excellent DC-stability, wide frequency range (DC-2MHz) and very low self-heating on current inputs.There is no need to fiddle with DC-compensation, or changing current plugging. All is built into the input sections of the power analyzer, ready for measurements. It is simple to use, your intuition will guide you to operate the Power Analyzer touch screen correctly.
-
product
30 A Current Shunt
34330A
Measure current safely with this precision 0.001 ohm resistor housed in a plastic case surrounded by epoxy.
-
product
CAN Sensor/ Interface
Current
Reach Technologies’ CAN Current Sensors sense and digitize conductor current for collection via CAN. The module is ideal for conveniently adding current data to a distributed CAN network. The CAN Current Sensor is configurable via J1939 or CANopen stacks, and are available in Hall Effect and shunt variants.
-
product
4-Ch DPDT 10A-250VAC 24VDC Multiplexer
H62004900
Up to 10A 250Vac 10mOhm Measurement Shunt Controlled via YAV90304 Form F
-
product
Turbine Flowmeters
Titan’s small turbine flowmeter range use a radial flow principle based on the Pelton wheel technique. This well proven method is the ideal way of measuring low rates of flow of low viscosity liquids. For these mini flowmeters, a jet of fluid is directed at a turbine that is mounted on robust low friction sapphire bearings. The geometry of the turbine and the fluid chamber ensures that the rotational speed of the rotor is proportional to the flow rate through the device. The use of this radial arrangement allows more energy to be imparted into the turbine, so the bearing drag is far less important. Furthermore, because more energy is available the bearings themselves can be a lot stronger so increasing the life of the flowmeter. For larger flows, some of the liquid can bypass the turbine chamber, which then behaves as a “shunt” to the metered fluid. Accuracy is still maintained and the output remains linear.
-
product
High-Voltage Isolation Amplifier
Knick Elektronische Messgeräte GmbH & Co. KG.
Measurement of DC or AC voltages up to () 3600 V and of large DC currents to about () 20 kA with shunt resistor or directly in the device to () 5A DC and AC. Variants with calibrated range selection.
-
product
DC Energy Meter
Multiple channels can be measured by a single meter, EN2450N & EN2450DDifferential current input for all the current channelsProgrammable shunt secondary 50mV to 100mVProgrammable CT Primary for all channels up to 200A - for Hall Effect CTData logging for parameters such as Energy, Load hours and Ampere hoursEasy installation,Compact size, weight and simple wiring
-
product
Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module
MODEL TMO-2A
The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
product
Phase Meter Current Shunts
610 and 650
Clarke-Hess Communications Research
The Model 610 and 650 Current Shunts are specifically designed to operate with the Model 6000A Precision Phase Meter. These shunts are frequency tuned to have negligible phase shift (less than 5m) at 50/60Hz making them ideal for line frequency applications. They can also be idealized for other frequencies as specified by the user. Consult factory for details.
-
product
DC Power Analyzer, Modular, 600 W, 4 Slots
N6705C
The N6705C DC Power Analyzer provides unrivaled productivity gains for sourcing and measuring DC voltage and current into the DUT by integrating up to 4 advanced power supplies with DMM, Scope, Arb, and Data Logger features. The N6705C eliminates the need to gather multiple pieces of equipment and create complex test setups including transducers (such as current probes and shunts) to measure current into your DUT. The DC Power Analyzer also eliminates the need to develop and debug programs to control a collection of instruments and take useful measurements because all functions and measurements are available at the front panel. For even greater control and analysis functions, the DC Power Analyzer can be used with the 14585A Control and Analysis Software. When automated bench setups are required, the N6705C is fully programmable over GPIB, USB, LAN and is LXI Compliant. 14585A Control and Analysis Software
-
product
AC Power Analyzers
Measure voltage, current and power on 4 channels: DC, 1-phase AC or 3-phase ACMake more accurate power measurements: 0.05% at 50/60 HzMeasure current directly: internal shunts to 50 Arms, or with external probes or transducersAddress multiple test scenarios with isolated inputs
-
product
Selectable Shunt Current Sensor ±40 V, 20 MHz
CX1104A
The CX1104A selectable shunt current sensor is a dedicated accessory for the CX3300 series and enables dynamic current measurements from 1 μA to 15 A up to 20 MHz bandwidth with an available calibrated resistive sensor head attached
-
product
Shunt: ACQ-200
BWB
*Constant Current up to 100 amps *Four Terminal Configuration*Excellent Long Term Stability*Max. Solder Temperature up to 350C/30 sec*RoHS and REACH Certified*AEC-Q200 Qualified
-
product
Differential Voltage Probes
DP150/DP200pro
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.
-
product
FD-11637, 8-Channel Strain/Bridge Input Device for FieldDAQ
785641-01
8-Channel Strain/Bridge Input Device for FieldDAQ - The FD-11637 can measure eight channels and has built-in bridge completion and voltage excitation to support for quarter-, half-, and full-bridge sensors. It also features anti-alias filtering, offset nulling, and shunt calibration to reduce the effect of noise and improve measurement accuracy. The FD-11637 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 grm vibration. The FD-11637 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11637 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11637 is ideal for test cell and outdoor environments.
-
product
Low Cost Precision Shunt
LPS
This is a precision metal clad resistor designed with four terminals. These models exhibit a high load capacity as well as excellent accuracy. The isolated voltage and current connections make them suitable for very precise current measurements. Direct attachment to current bus and connection to voltage using flexible wires enables easy current measurement.
-
product
100 Pin Breakout Interface
VSI-Breakout-100
The VSI-Breakout-100 is a very useful tool in debugging signals or software in a system. It allows unlimited access to signals within the cabling that might otherwise be difficult to access. The board gives test points at each side of the connector and jumper with a easy to use tabbed shunt to allow for easy disconnection of any particular signal between the connectors. The jumpers also give an opportunity to inject a signal regardless of what signal was originally being driven.
-
product
Signal Conditioners
General Purpose
Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.
-
product
Ultra High Power Precision Shunt Resistor
UHPS
*Max. current limit 707A*Excellent short term stability*Low temperature coefficient of resistance (T.C.R.)*High current sensing & reference resistors in laboratories*Change - discharge test equipment for high capacity batteries*Current sources & laboratory power supplies
-
product
37 Pin Breakout Interface
VSI-Breakout-37
The VSI-Breakout-37 is a very useful tool in debugging signals or software in a system. It allows unlimited access to signals within the cabling that might otherwise be difficult to access. The board gives test points at each side of the connector and jumper with a easy to use tabbed shunt to allow for easy disconnection of any particular signal between the connectors. The jumpers also give an opportunity to inject a signal regardless of what signal was originally being driven.
-
product
20V/30A/300W DC Programmable Electronic Load
TOB-IT8512
Xiamen Tob New Energy Technology Co., Ltd
IT8512 120V/30A/300W DC Programmable Electronic Load for Battery and Power Supply TestHigh performance and affordable single channel DC electronic load. TOB-IT8512 DC electronic loads provide you with the flexibility to test a wide range of applications from power supply, charger to battery. The high resolution voltage(1mV), current(0.1mA) measurement system provides both accuracy and convenience, and eliminates the need for a DMM, external shunts and wiring.
-
product
Shunt Resistor
RSR
Power converters and current measurement instruments. Large current shunt resistor for ampere-meters, designed for standard current measurement of electric equipment. Easy current measurement is performed by attaching to current bus bar directly and connecting to ampere-meter through flexible wires.
-
product
Torque Measuring and Monitoring System
WISER 4000
TECAT Performance Systems, LLC
The WISER 4000 system is the latest release of TECAT’s low-cost, ultra-low power and extremely accurate torque sensor. The wireless system has the optional ability to measure 3-axis acceleration, barometric pressure and ambient temperature, all within the same incredibly small footprint. The 4000 includes on-board data logging without PC or DAQ connectivity, and remote flash capability, which enables firmware upgrades without removing the system from the unit under test. Featuring shunt calibration, TECAT’s latest WISER system is designed to simplify instrumentation verification for users, while allowing them to check calibration of the system in the field. In addition, the WISER 4000 has been enhanced with two additional outputs, a higher-speed recording, and is available with custom-built remote enclosures to protect the system’s remote unit and battery from damage due to debris.
-
product
Electrical Standards
To verify the performance of an electrical calibrator or dc calibrator, you need an electrical standard. Fluke Calibration standards are found in primary calibration laboratories across the world. A wide range of electrical standards and frequency standards are designed to meet the needs of today’s laboratories for traceability and quality accreditation while also being portable, simple to use, and easy to support. Electrical standards include: Voltage standards; ac/dc transfer standards; ac measurement standards; resistance standards; ratio standards; current shunts.
-
product
AC Current Shunts
CSA Series
Ohm-Labs’ CSA series of ac current shunts are designed as laboratory standards for ac current measurement up to high frequencies.
-
product
Signal Conditioner
DMA2
Din rail mountable with user selectable outputs of +/-10V, +/-5V or 4-20 mA. 10-28VDC powered suitable for battery or automotive use. Features 1000 Hz bandwidth and push-button shunt calibration.
-
product
Precision Current Shunt
Has five precision selectable Ultra stable Current Shunts which ranges from 0.0001 to 1Ω. The Shunt T/C is less than 10ppm, and the internal current meter will measure from 1μA to 1000Amps.
-
product
Current Probes
Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.
-
product
15 Pin Breakout Interface
VSI-Breakout-15
The VSI-Breakout-15 is a very useful tool in debugging signals or software in a system. It allows unlimited access to signals within the cabling that might otherwise be difficult to access. The board gives test points at each side of the connector and jumper with a easy to use tabbed shunt to allow for easy disconnection of any particular signal between the connectors. The jumpers also give an opportunity to inject a signal regardless of what signal was originally being driven.
-
product
High Impedance Differential Clock Divider
Alliance Support Partners, Inc.
he ASP-DCD-00 board is a high impedance input clock divider circuit. It is designed to provide minimum load to a clock source for frequency measurement. It accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms; it divides the input signal frequency from 2 to 256 times depending on shunt jumper selections on J3. The board requires 5VDC 500mA power source to operate. The output is capable of driving 5V TTL logic levels.
-
product
NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module
783311-01
±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.