Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI Dual Bus 32-Chan 2A Fault Insert Switch, N/O Through Relays
40-190B-502
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
product
Proving Unit & Voltage Tester Kit
DLPK1
Touch electrode for Quick testing of fused leads Optical and acoustic continuity Indication Low battery indication A portable, battery powered Proving Unit for testing Two Pole Voltage Testers up to 690V Continuity Tester for testing: Fuses, Fused test leads etc
-
product
Electricians' Accessories
A selection of voltage detectors, proving units, test leads, certificate books and a DVD, which make it that bit safer and easier to get the job done.
-
product
Proving Units for High Voltage Testing Equipment
A high quality range of proving units provide the important role of verifying the safe operation of high voltage potential indicators used by power engineers, maintenance personnel and service engineers. The proving units are essential tools for testing HV equipment before and after use.
-
product
Proving Units
Designed to suit a range of applications in the electrical contracting power utilities and industrial engineering sectors Seaward proving units are both self-powered and self-testing avoiding the need for a known supply point or bulky test equipment.
-
product
Proving Unit
PRV240
The Fluke PRV240 provides a safe method to verify that your electrical test tool is operating properly before and after you conduct any live tests. The concept of “Test Before Touch” (TBT) involves testing your meter against a known live source before and after the actual measurement.
-
product
Test Voltage Indicators
PRV240FS
Verify your test tool works without unnecessary exposure to shock and arc flash. Make the process easy by using the PRV240FS Proving unit. Verifying that your T6 electrical tester is working properly reduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification before tests are performed.
-
product
H.V. Proving Unit (DCV)
2713 PU
Standard Electric Works Co., Ltd
● Designed to proof: -Phasing sticks. -High voltage detectors (contact type only, not to be used with non contact proximity detectors.) -High voltage and voltage testers.● Battery operated.● Led indicates when power is “ON”.● Small and hand-held.● Quick connection with normal 4mm test leads.
-
product
AC Voltage Proving Units
HLV-1
Standard Electric Works Co., Ltd
● Designed to proof. AC voltage detectors AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.
-
product
AC Voltage Proving Units
HLV-2
Standard Electric Works Co., Ltd
● Designed to proof. AC voltage detectors AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.
-
product
Insulation / Continuity Tester Proving Unit
PU250
The PU250 allows simple and quick check of insulation resistance and continuity for all makes of I/R testers.Regular checks outside of the formal calibration process are required for compliance with BS7671 and Part P.Proving unit to enable compliance to the requirement to maintain records of regular checks on the measurement characteristics and accuracy of test instruments.
-
product
AC Voltage Proving Units
HLV-3
Standard Electric Works Co., Ltd
● Designed to proof. AC voltage detectors AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.
-
product
Module Testing Station
QuickSun® 550CE
QuickSun 550CE is certified by TÜV Rheinland and a detailed test report is included with every simulator proving Class A+A+A+ performance with respect to spectrum, irradiance non-uniformity and short term instability (STI). Long term instability (LTI) is also within Class A+ tolerances during the 40 ms long flash pulse. IV characteristics are recorded with an electronic load and proprietary electronics unit which measures voltage, current and irradiance signals when module is swept e.g. from short circuit to open circuit or vice versa.
-
product
Proving Unit
PU260
Proving unit to enable compliance safety checking of voltage indicators for safe operation prior to testing on a live circuit.It is a requirement by Electrical Safety Council and the HSE that every electrician proves their voltage testers before confirming safe isolation.
-
product
Proving Unit& Calibrators
Shanghai Beha Electronics Co., Ltd.
Calibration box is used to verify and proof any High Voltage Insulation Testers. It can be utilized to calibrate all High Voltage Insulation Testers very accurately Analogs or Digitals.
-
product
Digital Source Capture Unit
DIO2
The DIO-II module is a multimode digital source and capture unit. In Low Speed Mode it provides a 20-bit parallel or 24-bit serial I/O capability running at speeds up to 50 MHz. In High Speed Mode, the DIO-II provides a 16-bit parallel I/O capability up to 200 MHz. In both Modes, the Clock is generated by a low jitter PLL source that is capable of generating clocks from 320 kHz up to 1 GHz.
-
product
PXI 10A Fault Insertion Switch 10-Chan 1-Bus
40-199-001
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
product
Single Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-201
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXI Source Measurement Unit
PX773x
The PX773x is a high precision, high speed source and measurement unit, which is designed for automated high throughput testing.
-
product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
Battery Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
product
Autonomous Driving AI Decision Making ECU
ADM-AL30
ADM-AL30 is dedicated to Autonomous Driving Applications. Powered by Intel® 12th Gen Core i9/i7 CPU and the NVIDIA RTX 4000 SFF Ada GPU, this AI computing platform can process huge amounts of data and make crucial decisions for autonomous vehicles. Equipped with 2 x 10G Base-T and 8 x 1G Base-T1 automotive ethernet ports, as well as 8 x CAN FD and 4 x CAN 2.0 interfaces, it seamlessly integrates into any automotive ecosystem. Plus, its ISO 16750-2 and ISO 7637-2 ensure reliability and safety under the most demanding conditions.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
product
PXI Single Bus 64-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-401
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI/PXIe Fault Insertion Switch, 32-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-212
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI Based Multifunction Measurement and ICT Instrument
PXI-501
The PXI-501 is a multifunction measurement instrument for functional and in-circuit measurements.It combines two parametric measurement units with a digital voltmeter, a high voltage current source and a discharge unit. This powerful combination makes it the ideal instrument for classical analog in-circuit test and manufacturing defect analysis with additional functional test capabilities.With it’s fast sampling rate of up to 4MSps it speeds up measurements and is capable of measuring and generating AC signals up to 100kHz.To enhance the PXI-501 capabilities it can be combined with an ABex TM-501 or an ABex TM-404. The ABex TM-501 enhances the in and output range of the PXI-501. Furthermore, it provides a shunt current measurement upgrade. In combination with the ABex TM-404 it’s a complete in-circuit test solution with 86 channels in one ABex slot. For sure it can be upgraded to 2838 test points in one rack by simply adding additional matrix modules.With the above-mentioned terminal modules, the PXI-501 is able to act as a ABex system controller, so that no additional controller is required in the cassis.
-
product
21-Ch 6A-250VA 2-Bus Fault Insertion
YAV90077
21 channels 1 thread 6A 250V 2 Fault Insertion Buses Switching up to 250W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
product
PXIe-4142, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit
782430-01
PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit - The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.