Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe Wide Current Range Multiplexer Module, Quad 6-Channel, 1-Pole
42-514-106
The 40-514-106 (PXI) and 42-514-106 (PXIe) are low density multiplexers in quad 6-channel, 1-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
Current Probe
Vernier Software & Technology, LLC
Simplify your experimental setup with the Go Direct Current Probe. It connects wirelessly via Bluetooth® or wired via USB to your device. The wireless connection eliminates additional cables that can clutter the lab bench. Capture small currents like those produced by a magnet falling through a coil.
-
product
Fatigue Testing And Certification
Fatigue engineering is subject to uncertainty, and data from well executed tests are used to validate conclusions made by analysis and to provide a basis for structural certification. Our staff have extensive experience in testing materials and components under slowly varying, static loads, and under rapidly varying cyclic loads. Tests under static loads are used to assess material properties or to assess the load-deformation behavior of structural components. Tests under cyclic loads provide time to crack initiation, time to failure, or measurements of crack growth over time. We have extensive experience in measuring fatigue crack growth behavior in metallic materials. Past programs have measured crack growth with microscopy and photogrammetry at the surface, cracked area with direct current potential drop, and through-thickness crack profiles with quantitative fractography. By assessing crack growth with a variety of experimental methods, we enable robust analysis validation for cases of complex cracking. Our capabilities in fatigue engineering allow for careful design of a fatigue test program. Whether the tests use constant amplitude loading or an irregular loading spectrum, we specialize in engineering the test that meet your needs. Much of our experience is in non-standard test programs, which require engineering to optimize the test setup. Few others match our capability and experience in fatigue test engineering.
-
product
Signal Generator, 20MHz, 2 Channel, Arb.
33512B
With these signal generators, Keysight introduces the highly accurate True form technology. It generates true point-by-point arbitrary waveforms with ten times less jitter than current Direct Digital Synthesis (DDS) technology. The tracking filters allow for clean, alias-free signals. The devices have USB, LXI and GPIB interfaces for remote control from the PC.
-
product
Supercapacitor Test
The CT3001A/C battery test systems are upgraded from CT2001A/C with higher precision and data logging rate. The tester can be used to run precision tests for coin cells, pouch cells, prismatic cells, and especially supercapacitors (ultra-capacitors). Each tester has 8 independent channel which can be programmed to run constant current charge/discharge, constant voltage charge, constant power discharge, constant resistant discharge, and direct current internal resistance (DCIR) tests.
-
product
DC Blocks
DC blocks are coaxial components that prevent the flow of audio and direct current (DC) frequencies while offering minimum interference to RF signals.
-
product
Open Loop Current Sensor
C03 30A
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
product
Combinated Current Clamps
PeakTech Prüf- und Messtechnik GmbH
Measure small direct and alternating currents up to 2 A with 1 mA resolution. The device measures the current indirectly via the surrounding magnetic field, so it is measured without contact when the clamp jaws enclose the current-carrying conductor (single wire).
-
product
DC Blocks
A coaxial RF DC block is from Pasternack and has an 50 Ohm impedance. Our 50 Ohm DC block is manufactured with a SMA input and SMA output. This SMA DC block is an inner direct current block type.
-
product
3-CH RTD Input Module
ND-6013
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
product
Portable Electricity Meter Testers
EE-120A-3S
The EE-120A-3S unit consists of a three-phase energy standard class 0.1 and current load up to 120A. The unit performs testing of all types of electricity meters using the voltages of the network. The meter error can be measured for active, reactive or apparent energy in Manual Mode or with predefined Test Plans using the keyboard and the LCD display on the panel. Maximum Demand Test, Register Test, Starting Current Test and No Load Test can be performed too. The energy standard of the system can be used without the phantom load to test meters with customer load and perform analysis of the three-phase network – with direct measurement or with optional current clamps.
-
product
Liquid Cooling High Amp
qCf 12 High Amp
qCf Liquid Cooling High Amp: Our system for the professional characterization of fuel cells for high current densities and direct flow field cooling.
-
product
Surge/wave Simulators
Suzhou 3ctest Electronic Co.,Ltd.
Surge pulses occur due to direct or indirect lighting strokes to an external circuit. This leads to current or electromagnetic fields causing high voltage or current transients. Another source for surge pulsed is switching transients originating from switching disturbances and system faults.
-
product
MicroLite USB Data Loggers
The family of MicroLite USB data loggers includes six models covering temperature, humidity, current and voltage measurements, providing the ideal solution for a wide range of industrial applications. Combining innovation with simplicity, the MicroLite product line offers cost effective logging, with rich functionality in a compact design, direct USB connection, multi-trip usage, and high measurement accuracy and resolution. Real-time sensor readings with a corresponding time stamp are clearly displayed on the logger’s LCD screen, incorporating alarm thresholds. The logger is designed for low power consumption to extend battery life and reduce the time between battery replacements. The comprehensive MicroLite range allows you to select the device most appropriate to your mission-critical application.
-
product
Electronic Resistance Store
MEMS2-4L
The mezzanine serves as an electronic store of resistance to direct current, the value of which is set by software, through two isolated channels.
-
product
Power Analyzers
At PCE Instruments you will find a power quality analyzer to measure the power in W, kWh or to analyze and measure harmonics. This power analyzer is a multi-function power analyzer device that measure precisely direct current, alternating current, AC-voltage, DC-voltage the intensity of DC or AC, phase rotation and idle, apparent and effective power. The reading of AC power is considered the real value and has a maximum range of 6000 Watts. While a reading is being taken, the polarity changes automatically, if negative values are taken then a minus sign will appear on the device display.Nowadays, power quality analyzers have many features such as, insulated current input, measurement of harmonics, AC and DC current measurement, AC and DC voltage measurement, frequency measurement, phase rotation measurement and idle, apparent and effective power measurement. All this data can also be logged and analyzed with the delivered PC-Software. Power analyzers of the type PCE PA 6000 can determine the energy in single-phase systems.Power quality analyzers of type PCE-GPA 62 allow the energy measurement in symmetrically loaded three-phase systems. Power analyzers of type PCE-PA 8000, PCE-360 and PCE-830 support professional power and energy measurements in single and three-phase systems.Apart from being used as energy-measuring devices, power analyzers like the PCE-830 can also be used for network analysis and the determination of harmonics and phase rotation. On our website you will find other power analyzers used in the field of electronics.
-
product
Electronic DC Load, 500V, 16A, 400W
LDH400 Series
Versatile solution for direct testing of dc power sources and PFCsConstant current, resistance, conductance and power modesWide voltage and current range, 10 to 500V and 0 to 16A400 watts continuous dissipation at 28°C (360W at 40°C)High resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingHigh resolution backlit graphic LCD with soft key controlAnalogue remote control of levels and TTL control of on/off and transient switchingFront and rear input terminalsLoad inputs rated to CAT II (300V)Full bus control via USB, RS232 and LXI compliant LAN interfacesGPIB Option
-
product
Wireless Energy Datalogger
ELITEpro XC™ Energy Logger
The ELITEpro XC is a complete solution for pinpointing electric usage and recording building performance metrics. It is capable of measuring, storing, and analyzing electrical consumption data which is derived from the voltage and current inputs. The ELITEpro XC uses direct connections to each phase of the voltage and various interchangeable CT options such as split-core current transformers, or flexible RoCoils (for large loads or large cables and bussbars) to monitor current on each phase.
-
product
PXI Single 8x2 1-Pole 10A Power Matrix
40-551-002
Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, the 8x4 module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.
-
product
20-Pin Scorpion Female Connector, 20A, Straight PCB Mount
C020AFX-2PS-2A
This is a female 20-pin Scorpion Connector, straight, suitable for PCB mounting. The connector is keyed to position 1 and it has a maximum current handling of 20A and is suited for direct connection to Pickering Interfaces products.
-
product
Quad Ammeter
4014
Red Phase Instruments Australia Pty Ltd.
The Model 4014 integrates four ammeters for the direct and simultaneous reading of C.T. secondaries up to 10A during the setting up or checking of protection systems while they are in service with normal 50/60Hz primary currents flowing. The two terminals of each channel of the Model 4014 are connected in series with the C.T. secondary with all other equipment in the loop or directly across the C.T. secondary.
-
product
8-CH Analog Input Module
ND-6017
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
product
Low Cost Precision Shunt
LPS
This is a precision metal clad resistor designed with four terminals. These models exhibit a high load capacity as well as excellent accuracy. The isolated voltage and current connections make them suitable for very precise current measurements. Direct attachment to current bus and connection to voltage using flexible wires enables easy current measurement.
-
product
Non-contact Io/Ior Leakage Clamp Meter
MCL-500IRV
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Available direct voltage input at live part as ordinary.・True RMS measurement (I, Io, V).・With filter switch to cut high frequencies.
-
product
Multimeter Test Probes
Multimeter Test Probes, Voltmeter test leads,with the Parrot™ Clip Invention provide precise, HQ, accurate, reliable contacts and connections. Parrot™ Clips with HQ leads and banana plugs or other connectors are the best solution for DDM, analog multimeter for high voltage measurements as well as for high current measurements. Measurements with multimeter test probes require both: Hands-on direct point contact and grip on, Hands free removable connection.
-
product
Signal Generator, 20MHz, 2 Channel
33510B
With these signal generators, Keysight introduces the highly accurate True form technology. It generates true point-by-point arbitrary waveforms with ten times less jitter than current Direct Digital Synthesis (DDS) technology. The tracking filters allow for clean, alias-free signals. The devices have USB, LXI and GPIB interfaces for remote control from the PC.
-
product
LV Iron Core Smoothing Reactors
Smoothing Reactors are serially connected reactors inserted in DC systems to reduce harmonic currents and transient over currents and/or current ripples in DC systems. They are necessary in order to smooth the direct current wave shape to reduce losses and improve system performance.
-
product
DC Blocks
Coaxial components that prevent the flow of audio and direct current (DC) frequencies while offering minimum interference to RF signals.
-
product
Inverters
An inverter is a power device that transforms DC to AC (Direct Current into Alternating Current). A typical application would be to convert your available battery or DC power to AC to power sensitive electronic devices that require clean, low distortion sine wave inputs (i.e. microprocessor based instruments and PLC's).
-
product
Magnetic Field Meter
Measurement for the magnetic field generated from Direct Current (DC, with display by N/S Magnetic polarity) or Alternating Current (AC in 40-500Hz).
-
product
Flexible Current Sensor Probe
CTA
The CTA current sensors convert ac current to an isolated 0-5A current with available ranges from 100A to 10,000A. Because the current sensors are flexible split core, installation is possible without shutting down the LV electrical supply, avoiding expensive down-time costs. Typical applications are retrospective energy monitoring in factories, offices buildings, process control data logging systems, where power, energy and current monitoring is important. Typical applications are factories, offices buildings, ac/dc VFD drives, welding, power conversion and power distribution. For all CTA current sensor models, a NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied. All CTA sensors use UL94V0 or CSA approved materials. The CTA flexible current sensors are suited to permanent or semi permanent installation. The coil sensor is durable, lightweight, flexible and will easily clip-around a power cable. The 5A output from the CTA current sensor connects direct to installed metering, rotary metering or current transducers.