Filter Results By:
Products
Applications
Manufacturers
Pulsed Lasers
A single or repetitive burst of laser energy with a pulse equal to or less than 0.25 s in duration.
See Also: Autocorrelators
-
product
Lasers FP/DFB-LDs For OTDR
C is a 1 650 nm Multiple Quantum Well (MQW) structured Distributed Feed-Back (DFB) pulsed laser diode DIP module with single mode fiber and internal thermoelectric cooler. It is designed for light sources of Optical Time Domain Reflectometer (OTDR).
-
product
Wavelength Meters - Scientific
Bristol Instruments'' wavelength meters are for scientists and engineers who need to know the exact wavelength of their lasers. These systems use proven interferometer-based technology to measure absolute wavelength to an accuracy as high as 0.0001 nm. To achieve the reliable accuracy that is expected from Bristol Instruments, all of its wavelength meters include a built-in wavelength standard for continuous calibration. Systems are available for CW and pulsed lasers that operate at wavelengths from 350 nm to 12 m.
-
product
12-Watt Pulsed FAYb Fiber Laser
LP-V Series
Panasonic Industrial Devices Sales Company of America
The LP-V series is a 12-watt, pulsed fiber laser.Characteristics:- Very high resolution- Fine marking area- Small air cooled head
-
product
Raman Spectrometer
S-RS
Main features of this system are an adaptation a super stable single mode 500-picosecond pulsed Diode Pumped Solid State Lasers (DPSSL) with more than 8 kW peak power as a probe beam.
-
product
Near IR Image Plates
The IR Display Plate is a versatile instrument that presents clear, high contrast images of all near IR laser beams. These displays are made on infrared sensitive phosphors which offer a variety of unique features, variable image retention times for pulsed lasers, high resolution for CW YAG, and a good response to gallium arsenide light-emitting diodes. All near IR lasers are capable of being displayed over a wide sensitivity range.
-
product
Laser Applications
Quantum Composers offers a diverse family of lasers, laser systems, and modules, including DPSS, Nd: YAG, and pulsed lasers. Our MiniJewel and MicroJewel lasers are now available in 2 different energy options to allow customers to tailor the laser to their specific applications.
-
product
Beam Profiler
WinCamD series
CW & Pulsed laser profiling. Wavelength Range: 190 nm- 15 m*. Resolution: 5.0 m*. Smallest Beam: 42 m*.
-
product
SpikeSafe DC / Continuous Pulsed Current Sources
The Vektrex SpikeSafe™ DC / Continuous Pulse (DCP) Current Sources provide reliable DC or pulsed drive for LED or laser diode reliability testing, IESNA LM-80 maintenance testing, and other test applications requiring DC or continuous pulse current. Models support currents from 500mA to 60A and compliance voltages from 50V to 400V. All models feature individual channel control, accurate pulsing over long output cables, precise current, precision pulsing for improved measurement repeatability, and high power density — typically 6.4kW-8kW.
-
product
Laser Diodes
Our laser diode portfolio is broad, extending from cw laser diodes to pulsed laser diodes to high-power laser diodes. For special areas of application VCSELs and quantum cascade lasers are also included in our range of products.
-
product
Pulse Laser
Is a variable, pulsed high power laser source, a building block ideal for MOPA, LIDAR, OTDR laser systems development and applications. This fully integrated compact module contains a Distributed Feedback (DFB) laser and built-in optical amplifier stage, and a variable nanosecond pulse generation circuits. It provides up to 200 mW optical peak power in 1064 nm wavelength region, with a programmable pulse width from 10 ns to 1000 ns, and a selectable pulse repetition rate from 100 Hz to 1 MHz The optical pulse generation can alternatively be controlled via an external electrical trigger. In a compact design, NPL-CWDM-M is applicable for OEM integration or as a stand alone pulsed laser source. Contact Optilab for more information.
-
product
Spectrometer - OSA
HighFinesse optical spectrometers LSA and HDSA are designed to analyse the multi-line or broadband spectrum of (un-)known light sources like cw and pulsed lasers, gas discharge lamps, super luminescence diodes, semiconductor laser diodes and LEDs. They are suitable to analyze the spectrum of telecom signals, resolve Fabry-Perot modes of a gain chip, and produce a spectral measurement of gas absorption.
-
product
Laser Diode
Yisinc Optical Technology Co., Ltd
Laser diode is an efficient radiation source for CW and pulsed operations.
-
product
Camera Based Beam Propagation Analyzer: M2
BeamSquared
The BeamSquared® system is a compact and fully automated tool for measuring the propagation characteristics of CW and pulsed laser systems from the UV to NIR to Telecom wavelengths. Users can also measure wavelengths above 1.8 microns, including CO2 and terahertz in manual mode (a bench set-up; without the automated optical train) with a Pyrocam IV or IIIHR. Our longer optical train and patented Ultracal™ Calibration makes BeamSquared the most accurate product on the market and is ISO 11146 compliant. Its operational robustness and reliability ensures continuous use applications in industry, science, research and development.
-
product
PLD/PED Components
Neocera offers a variety of components that can be fitted and combined into new or existing PLD and PED systems to provide improved functionality and enhanced capability. Components include:*Oxygen-compatible substrate heaters for epitaxial oxide film depositions..*Automated Target Carousels for preparing multilayer heterostructures.*Deposition chambers design specifically for PLD and PED systems.*Manual and automated laser window-change Accessories.*Pulsed Electron Deposition (PED) sources for laser transparent materials.*Ideal for retrofitting existing systems or construction of new systems.
-
product
Extreme Low Power Detector Laser Power Meters
11XLP12
11XLP12 extreme low power detector is best suitable for low power im both the µW and mW regimes with very low thermal drift. Featuring broadband flat spectral response, minimal thermal drift and a noise equivalent power as low as 1 µW the 11XLP12 is ideally suited for measuring any pulsed or CW low power laser.
-
product
NanoModeScan M² Measuring System
This scanning slit M² measurement system accurately analyzes lasers with wavelengths from UV to Far Infrared with its silicon, germanium, or pyroelectric head. It features a compact portable design, immediate results, ISO compliant measurements, and operates in CW or kHz Pulsed modes which makes it ideal for comprehensive analysis of lasers of most wavelengths.
-
product
Continuous-wave (CW) Lasers
Continuous-wave lasers (cw lasers) emit a continuous laser beam as compared to ultrafast or pulsed lasers that emit a pulsed laser beam. Spectra-Physics offers wavelength tunable cw lasers, standard cw lasers, quasi-cw lasers, and accessories for continuous-wave lasers.
-
product
Pulsed and CW lasers, 375 – 1700 nm, 1 kHz measurement rate
871 Series
The 871 Laser Wavelength Meter from Bristol Instruments is the best way to measure the absolute wavelength of both pulsed and CW lasers and OPOs. By combining proven Fizeau etalon technology with automatic calibration, the reliable accuracy needed for the most meaningful experimental results is ensured. What’s more, a sustained measurement rate of 1 kHz enables the wavelength characterization of every single pulse for most lasers. And, the resulting time resolution of 1 ms provides the most detailed analysis of tunable lasers.
-
product
*Pulse Characterization Sensors
Pulse Characterization Sensors provide the ability to see and measure the temporal characteristics of pulsed and CW laser beams. Ophir Fast Photodiode Detectors are designed to convert optical signals into electrical signals which are then measured with third-party instrumentation such as oscilloscopes and spectrum analyzers. Accessories are available to connect to IS6 integrating spheres or fiber optic cables. Attenuating filter accessories are also available to increase their dynamic range. Different models offer silicon, UV enhanced silicon and InGaAs PIN photodiodes, covering a combined spectral range of 193 nm to 1700 nm. Rise times range from 25 picoseconds to 3 nanoseconds. The fast rise times are achieved by an internal reverse bias voltage circuit. Power is supplied by internal batteries and/or an external power supply depending on the model. Detectors should be connected to a 50Ω impedance in order to maintain their nominal rise times. They can be connected to higher impedance loads, but this will result in a significant increase in the rise time. If higher output voltage is required, it is recommended to connect the detector to a trans-impedance amplifier with an Input impedance of 50Ω
-
product
Widely Tunable Mid-Infrared Quantum Cascade Laser
LaserTune™
Block Engineering's next generation LaserTune represents a significant leap forward in offering the ultimate mid-IR, pulsed Quantum Cascade Laser (QCL) source to meet the ever challenging requirements of the research community. The fully integrated "single box" concept has been taken to new extremes with a significant reduction in footprint size, saving considerable laboratory bench space. This single box also offers the widest gap-free tuning range available on the market of 5.4 - 12.8 microns. No external power supply or control peripherals are required.
-
product
PED Systems
Pulsed Electron Deposition
Is a process in which a pulsed (80-100 ns) high power electron beam (~1000 A, 15 kV) penetrates approximately 1 μm into the target resulting in a rapid evaporation of target material. The non-equilibrium heating of the target facilitates stoichiometric ablation of the target material. Under optimum conditions, the target stoichiometry is preserved in the deposited films. All solid state materials – metals, semiconductors and insulators, including those transparent to laser wavelengths in PLD – can be deposited as thin films with PED. By combining PLD and PED, the range of complex materials that can be prepared as thin films can be greatly enhanced.
-
product
Nitrogen Laser
NL100
Stanford Research Systems, Inc.
The NL100 Nitrogen Laser is ideal for fluorescence measurements, MALDI-TOF mass spectrometers, and other pulsed UV radiation experiments. It provides 3.5 ns pulses at 337 nm (UV), with repetition rates up to 20 Hz.
-
product
KATANA & PILAS Pulsed Diode Lasers
With external trigger functionality, nano- to picosecond pulse duration, and a wide range of wavelengths, the KATANA & PILAS series are our most versatile offering.
-
product
Current Pulsers and Laser Diode Drivers (Pulsed Current)
These instruments generate current pulses whose amplitude is largely independent of the load voltage. This makes them ideal for pulsing device whose voltage may vary with time (for instance, the voltage drop of laser diodes may vary with temperature, or explosive squibs which change impedance during ignition). This voltage independence is a trade-off with speed. If faster rise times are required, consider using pulsed voltage instruments instead.
-
product
FAYb Fiber Laser Markers
LP-S Series
Panasonic Industrial Devices Sales Company of America
The LP-S Series Fiber Laser Marker features:- Compact IP67G-Rated Head For Harsh Environments- 17 And 42 Watt Models, Pulsed Fiber Laser- Marking Area Up To 160mm- Removable Fiber Cable For Ease Of Installation
-
product
Energy Detector Laser Energy Meters
11QE25-LP-S-MB
11QE25-LP-S-MB energy detector provides a unique combination of high damage resistance and high speed. It also offers very good linearity with power and a versatile mounting system. It is right for many pulsed lasers. It is right for many OEM, manufacturing and laboratory uses.
-
product
Photodetectors
Packaged photodetectors based on PIN photodiodes for monitoring Q-switched and mode-locked pulsed lasers.
-
product
Visual Fault Locator
OrienTek Optical Technology Ltd.
powerful, mini visual laser source for fiber fault locating. It has attractive design and small size and it is easy to operate. ● Bright red laser at 650nm● Pulsed and CW operation● Outpower: 1mw,10mw,20mw,30mw● 2.5mm universal connector● 40 hours of operation(1mW)● Pocket size design● 1.25 mm adapter for LC (optional)
-
product
Optical Camera Trigger
The Optical Camera Trigger is an optical sensor that detects pulsed light sources and generates outputs to trigger a camera. The front aperture of the Optical Trigger must be directed at a light source that provides the necessary properties for trigger activation. (e.g. a laser flash lamp, a pick-off source from the main laser beam, or similar). The light source may be a direct or indirect pulsed waveform.
-
product
Compact Juno USB Interface
Juno 7Z01250
*Virtual laser power meter - From sensor to interface to PC - no power source needed*Plug and play with all standard Ophir smart sensors*Use with StarViewer free Android app to turn your smartphone / tablet into a power meter*Record every energy pulse at up to 10 KHz*Log power and energy, average, statistics, histograms and more with included StarLab application*New: Pulsed Power measurements with Thermopile sensors*New: Low Frequency Power on Photodiode sensors - power measurement based on pulse cycle (for VCSEL)*System Integrator Tools included: LabVIEW VIs, COM Object Interface*Very compact - is just an extension of the smart plug