Validyne Engineering
A leading manufacturer of pressure transducers, pressure transmitters, signal conditioning in rack mount format and in portable units for field testing, and data acquisition systems with expandable chassis designs as well as PC based products for industrial and laboratory testing applications.
- (818) 886-2057
- (818) 886-6512
- sales@validyne.com
- 8626 Wilbur Avenue
Northridge, CA 91324
United States
-
product
Portable Carrier Demodulator with Digital Display
CD379
The CD379 is a portable, completely self contained digital transducer indicator. In addition to the front panel liquid crystal digital display, the unit also provides a 2 Vdc analog output suitable for recording, remote display or control purposes. The unit is for use with all variable reluctance transducers and features solid state electronics, 3 1/2 digit liquid crystal display and battery pack with six 1.5V penlight cells for truly portable operation. The unit can also be powered from an external DC power supply or AC battery eliminator (converter) module.
-
product
Low Range Low Cost OEM Differential Pressure Transducer
P17
The P17 OEM Low Range Low Cost pressure transducer features high sensitivity to very low pressures with full scales available down to 0.1 In H2O. Output signal is 5 Vdc and power can be +5 to +28 Vdc. Zero and Span adjustments are included. The P17 has a robust steel sensor construction.
-
product
Carrier Demodulator with LED Display
CD23/223
The CD23 and CD223 Digital Transducer Indicators are designed for use with variable reluctance and differential transformer transducers. The CD23 accepts input from a single transducer, and the CD223 accepts two switch-selectable inputs, with Zero and Span controls for each input. The indicators provide 5 Vrms, 5 kHz carrier excitation voltage to the transducer(s) and solid state circuitry to amplify, demodulate and filter the transducer output signals. A 3 1/2 digit front panel display is standard, with a 4 1/2 digit display optionally available.
-
product
Ultra Low Pressure Transmitter
P532
Validyne's P532 Pressure Transmitters are ideally suited for measuring extremely low liquid and gas pressures in industrial applications. Full-scale differential pressure ranges from 0.10 H2O to 2 H2O with line pressure rating of 100 psig, and ranges of 2 H2O to 3200 psid with line pressures up to 3200 psig are offered. Gauge pressure ranges start at 0.10 H2O and absolute pressure from 0.08 psia full-scale. This unique design, which utilizes a diaphragm-type variable reluctance pressure sensor, provides many outstanding advantages including:
-
product
Wet-Wet Differential Pressure Sensor
DP303
The DP303 features "take-apart" construction enabling the user to easily disassemble the unit for cleaning or to change full scale range by exchanging the sensing diaphragm. As noted from the Pressure Range/Diaphragm Selection Chart on the reverse side of this Data Sheet, a family of interchangeable diaphragms are available to cover virtually any full scale pressure range from 0.08 psid full scale to 5,000 psid full scale-all rated for operation at 5,000 psig line pressure!
-
product
ReCalibration and Post Calibration Software
SI58
The SI58 software allows the user to set zero and span as well as do full temperature compensation and linearity corrections for your Validyne USB pressure transducer. The SI58 provides everything needed to change the range of your transducer and calibrate it through the new full scale pressure. Corrections to non-linearity and temperature error are also possible. The SI58 software provides prompts to the operator for temperature and pressure points to achieve an accurate calibration.
-
product
High Line Pressure Variable Reluctance Pressure Sensor to 10,000 psid
DP360/DP363
The DP360 can be calibrated for a full scale as low as ±50 psid while withstanding high static line pressure. Low differential pressure may be measured at static pressures as high as 10,000 psig with a maximum 3% FS zero shift error.
-
product
Test and Measurement Grade Pressure Transducer for CAN Bus
P896
The P896 is a test and measurement grade pressure transducer for applications requiring high accuracy and outstanding performance through ambient temperature changes. The P896 is digitally compensated and corrected to provide high accuracy pressure measurement in a robust cylindrical form factor.
-
product
Variable Reluctance Pressure Sensor with All-Welded Construction
DP10
The DP10 Pressure Sensor, is designed for low and medium pressure measurements, to laboratory accuracy, of corrosive liquids and gases. In typical AC excited bridge circuits, this transducer delivers a full scale output of 30 mV per volt at 3kHz. The unit operates with carrier system including the Validyne CD15 since wave carrier demodulator and CD16 miniature DC input DC output carrier demodulator.
-
product
Test and Measurement Pressure Transducer
P895
The P895 is designed for a wide variety of pressure measurements where high resistance to vibration and superior stability through temperature change is required. The zero and full-scale output calibrations are set by the potentiometer adjustments accessible from the top cover.
-
product
Vehicle Pressure Acquisition System
VPAS
The Vehicle Pressure Acquisition System (VPAS) is designed to record and display up to 8 or 16 low pressure measurement points for the investigation of vehicle pressures within the passenger cabin, in HVAC ducting or with respect to the exterior of the vehicle. Validyne DP103 pressure sensors can be ordered with full scale ranges as low as 0.1 in H20 and up to 55 in H20.
-
product
Universal Data Acquisition System
(UDAS/USB2250)
The Universal Data Acquisition System(UDAS) Sensor Interface provides real world data acquisition for your PC via the USB port. 16 sensor inputs in any mix or combination are accepted by the UDAS. No external signal conditioning is required. The UDAS includes configuration and data acquisition software.
-
product
General Purpose Pressure Transducer and Transmitter
P55
The robust P55 pressure transducer provides cost-effective reliability for severe test environments. With extreme resistance to shock and vibration, the P55 pressure transducer delivers the same high-level performance expected from more delicate differential pressure transducers and pressure transmitters. With variable reluctance sensing technology, the P55 pressure transducer delivers fast dynamic response, high resistance to vibration and superior signal stability through ambient temperature change for a wide variety of low-pressure to high-pressure measurements. The P55 pressure transducer will accept both liquids and gases directly at the sensing diaphragm and there are no internal isolation fluids to slow the sensor response or cause excessive temperature drift errors.
-
product
Very Low Pressure Variable Reluctance Sensor
DP103
The Validyne DP103 is designed for exceedingly low differential pressure measurement applications where high accuracy is required under rough physical conditions. With full scale ranges down to -0.008 psid (-0.56cm H2O), this instrument is being used in the measurement of very low flow rates of gases where symmetrical pressure cavities are required for dynamic response. It is also used in very small leak detection and pressure null detection systems.
-
product
HVAC Pressure Transmitter
DP850/851
The DP850/851 transmitters are designed for low pressure measurement in HVAC applications. The DP850 is available in full scale pressure ranges as low as 0.25 inH2O and the DP851 can be ranged to 0.025 inH2O full scale. Both models are available in 4-20 mA or 0 to +5 Vdc signal output options.