Langer EMV-Technik GmbH
Langer EMV-Technik GmbH is a medium-sized electro-technical company which is active in the field of electromagnetic compatibility-related
- +49 (0) 351 430093-0
- +49 (0) 351 430093-22
- mail@langer-emv.de
- Nöthnitzer Hang 31
Bannewitz, D-01728
Germany
-
product
Immunity
RF coupling
is used for the conducted measurement of the immunity according to IEC 62132-4.
-
product
Immunity
EFT coupling
s used for direct-contact measurements of impulse immunity in IC pins, according to IEC 62215-3 and IEC 61000-4-4.
-
product
Near Field Micro Probe Sets
The near field probe is designed for a high-resolution measurement of electrical near fields.
-
product
Near-Field Probes 100 kHz up to 50 MHz
LF1 set
The LF1 near-field probe set consists of 4 shielded near-field probes used during the development process for emission measurement of longwave, medium wave, and shortwave frequencies on electronic devices. The probe heads of the LF1 set are designed for incremental detection of sources of electromagnetic interference on assemblies. First, the electromagnetic interference of the assembly is detected by the LF-R 400 probe from up to 10 cm. Then probes with higher resolution like the LF-B 3, LF-U 5 and LF-U 2.5 are used to more precisely detect any source of interference. The probe heads are designed for taking measurements at single pins and larger components. Near-field probes are small and handy. They have a current attenuating sheath and, therefore, are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. The H-field probes do not have an internal terminating resistance of 50 Ω.
-
product
Scanner Probe
RFS set
The RFS set consits of three passive near field probes designed for the use in a measurement scanner during the development of E-field and magnetic field. They are designed for frequency ranges of 30 MHz to 3 GHz. The probe heads of the RFS set allow for close measurements needed to correctly localize interference sources on an electronic assembly. They document the whole image of the device under test`s near field. The scanner probes have a sheath current attenuation and are electrically shielded. They are connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance. The measuring signal can be increased with PA 203 or PA 303 preamplifier. On request RFS, LFS and XFS scanner probes can be produced.
-
product
Near Field Microprobe E-field 7 MHz to 3 GHz
ICR E150
The near field microprobe is used to measure electric fields at extremely high resolution and sensitivity. The optimal distance to the object being measured is < 1 mm. Due to its small probe head dimension, the probe has to be moved by a manual or automatic positioning system, e.g. Langer-Scanner.
-
product
Micro probes 1 MHz up to 6 GHz
MFA 01 set
The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
product
IC Measurement Technology
Emission
is used to measure conducted emissions (measurements with direct 1 Ohm/150 Ohm-coupling) according to IEC 61967-4 at IC pins.
-
product
H-Field Burst Detector
BD 11
The BD 11 is used to detect a burst or ESD current pulse on a cable, for example in a complex system. This makes it easier to investigate the causes of sporadic faults in the system. It is small and handy, its sensitivity is very high and continuously adjustable.
-
product
Preamplifier
Is designed for the amplification of measuring signals, e.g. weak signals of near field probes with high resolution.
-
product
MP CI set
The MP CI set up to measure coupling impedance is used to determine EMC characteristics of connectors and cables. The coupling inductivity defines the coupling inductance of external disturbance on the shield or on the ground with the desired signals. If the coupling inductivity is considered in the construction set-up and the pin or wire assignment of connectors or cables, then the connectors or cables will be more interference-resistant. The MP CI set-up for measuring coupling impedance can be used for following measurements at connectors or cables: 1. measurement of a single signal (common mode) 2. measurement of a symmetrical signal (common mode) 3. measurement of a symmetrical signal (differential mode)
-
product
Immunity
ESD coupling
is used for conducted coupling of Langer ESD pulses (200ps rise time) into ICs.
-
product
Immunity Development System
Used for EMI suppression in printed circuit boards during the development phase. The developer can use the E1 set to quickly identify the causes of burst and ESD interference. This allows the developer to design suitable measures to solve the causes of the interference. It can also be used to test the effectiveness of the measures taken.
-
product
Measuring and Calibration Stations
PCB
Is used to measure electric and magnetic fields of an ESD generator